GV35 User manual
TRACGV35UM001
- 15 -
Table 7: Electrical Characteristics of Ddigital Output
Logical State
Electrical Characteristics
Enable <1.5V
@150mA
Disable Open
drain
Figure 10. Typical Connection with LED
Note:
1 - OUT1 will latch the output state during reset.
3.8.
Relay
There is a built-in relay on GV35. The relay can latch the output statue when
there is no control to relay. The rating load of the relay is 20A/14V..
Table 8: Electrical Characteristics of relay
Electrical Characteristics
Max. Switching Power
280W
Max. Switching Voltage
18VDC
Max. Switching Current
25A
Contact Resistance
≤
100m
Ω
Rating Load
20A/14VDC
Initial Insulation Resistance
Min. 100M
Ω
500VDC