EN
.
23
10. Associations
Use associations for direct communication between the Weather station and other devices
within your Z-Wave network without the need to use the gateway (hub).
Association Groups:
Root device:
Group 1: Lifeline group (reserved for communication with the gateway (hub)), 1 node
allowed.
Group 2: basic on/off (triggered when the Wind Gust of the Wind Gauge exceeds the
Configuration Parameter 1 Value), up to 16 nodes.
Group 3: basic on/off (triggered when the Rain rate exceeds the Configuration
Parameter 2 Value) up to 16 nodes.
End point 1: Thermo/ Hygro Sensor Ch1 – Temperature
Group 1: Lifeline group, 0 nodes allowed.
Endpoint 1 receives Temperature data from Thermo/Hygro Sensor on Channel 1. It is capable of
receiving data in range of -199.0°C and 199.0°C. However, the operating temperature of the
433 MHz sensor is from -10°C to 60 °C.
End point 2: Wind Gauge – Direction
Group 1: Lifeline group, 0 nodes allowed.
Endpoint 2 receives Direction data from Wind Gauge. The data is in the range of 0.0° to 360.0°.
Endpoint 3: Wind Gauge – Velocity
Group 1: Lifeline group, 0 nodes allowed.
Endpoint 3 receives wind speed data from Wind Gauge. It is capable of receiving data in the
range of 0.00 m/s to 88.00 m/s.
End point 4: Wind Gauge – Wind gust
Group 1: Lifeline group, 0 nodes allowed.
Group 2: basic on/off (triggered when the Velocity exceeds the Value of Configuration
Parameter 1) up to 16 nodes.
Endpoint 4 receives wind speed data from Wind Gauge. It is capable of receiving data in the
range of 0.00 m/s to 88.00 m/s.