![QUBINO ZMNHHD1 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/qubino/zmnhhd1/zmnhhd1_user-manual_3580043036.webp)
EN
.
36
ⓘ
NOTE: the reset with switch connected to I1 is possible only in the first minute after the device
is connected to the power.
ⓘ
NOTE: after the reset is successfully done the autocalibration will trigger and the green LED
will start blinking.
LED SIGNALIZATION FOR INCLUSION/EXCLUSION
LED (green)
•
LED is blinking (1 sec ON, 1 sec OFF) = module is excluded
•
LED is ON = module is included
LED (red)
•
LED is OFF = normal operation
•
LED is ON = overload
•
LED is blinking (1 sec ON, 1 sec OFF) = over temperature
LED (blue)
•
LED is OFF = normal operation
•
LED is blinking (1 sec ON, 1 sec OFF) = calibration in progress
•
LED is ON = calibration failed
ⓘ
NOTE: after each power cycle all 3 LEDs will blink once before resuming normal operation.