Installation 

 

 

 

QubEV 

 

QUBEV-UG-02  Installation and Operation Manual 

Page 

10

 of 

15

 

 

November 2020 

Installation Procedure 

 

WARNING: Electrical Power 

Make sure electrical power is isolated BEFORE starting this procedure. 

x

 

Turn power OFF at SOURCE. 

NOTE: 

All electrical work must be performed in accordance with the current Electrical Wiring 

Regulations.

 

CAUTION: Equipment Damage 

During the next steps, the charger front panel will be removed. Take care to not damage or 

strain cables or cable connections that run between the chassis and the front panel. 

1.

 

Remove the QubEV from the packaging. 

2.

 

Remove and retain the fixings that secure the front panel to the charger body.  

3.

 

Carefully ease the front panel away from the charger body to gain access to the interior.  

CAUTION: Equipment Damage 

The front panel is connected to the charger body by electrical cables. Take care not to 

damage, strain, or disconnect the cables. At the end of the procedure, make sure all 

connections are secure before refitting the panel. 

4.

 

Visually inspect the QubEV and internal components. 

x

 

Components that have come away from the DIN rail may be refitted to the rail if 

there is no damage to the component or its securing mechanism.  

IMPORTANT

: Items damaged in transit must first be reported to the courier and then 

to the supplier.  

x

 

Where possible, photographic evidence of package and/or unit damage 

should be provided. 

x

 

Incorrect or damaged units must NOT be installed. Contact your supplier to 

discuss rectification. 

5.

 

Remove the fixing template from the packaging. 

6.

 

Use the fixing template to mark the mounting position. 

x

 

Offer the QubEV fixing template up onto a flat and smooth surface.  

x

 

Make sure it is orientated correctly and is level. 

x

 

Mark the 4 fixing holes onto the surface. 

7.

 

Drill 4 x marked fixing holes and insert the wall plugs. 

8.

 

Make note of the position of the electrical connection terminations within the charger 

body. 

9.

 

Cut a neat hole in the charger body to allow entry of the power cable. 

x

 

Ideally, the cable should enter the charger body from below. 

x

 

A suitable cable gland must be used to maintain the IP integrity of the unit. 

10.

 

Make sure all debris is removed from the charger body. 

11.

 

Secure the charger body to the mounting location with the appropriate fixings. 

Содержание EVON0010

Страница 1: ...some useful hints and tips as we want your experience with the QUBEV to be as smooth as possible Model No EVON0010 EVON0040 REF QUBEV UG 02 INSTALLATION USER GUIDE UNIVERSAL ELECTRIC VEHICLE CHARGER...

Страница 2: ...Code QUBEV UG 02 Language UK English Original Date Published November 2020 QubEV are the publishers of this document and own the rights to use the text images and all technical content contained withi...

Страница 3: ...s 6 Typical Options 7 Installation 7 Before Installation 7 Labelling 8 Schematics 8 Installation Procedure 10 Commissioning 11 Set the Charger Power 11 AMP Setting Record 12 Testing 12 After Installat...

Страница 4: ...r to property caused by improper installation are the responsibility of the installer x The information provided in this manual must ONLY be used with the model s listed on page 2 of this manual x The...

Страница 5: ...OTES are given to provide additional information and or to highlight information of importance They will be given either before or after the detail instructions as appropriate and may use different wo...

Страница 6: ...21 2002 EN 61851 22 2002 Wiring Regulations BS 7671 IET EV Regulations Glow Wire Testing IEC 60695 2 13 EMC Compliance 2014 30 EU EN 61000 6 3 2007 EN 61000 6 2 2005 Safety Compliance EN 60950 1 2006...

Страница 7: ...urther advice and or training BEFORE attempting installation operation of the equipment x The manufacturer distributor cannot accept any responsibility for improper installation or any problems arisin...

Страница 8: ...al Page 8 of 15 November 2020 Labelling Installers must observe any all warning labels displayed on the equipment or inside the equipment enclosure Figure 2 Product Label Schematics Figure 3 EVON0010...

Страница 9: ...tion and Operation Manual QubEV September 2020 Page 9 of 15 Figure 4 EVON0040 Schematic Diagram EARTH IN ACCORDANCE WITH CURRENT REGULATIONS Appropriate cabling between the consumer unit and charger m...

Страница 10: ...and internal components x Components that have come away from the DIN rail may be refitted to the rail if there is no damage to the component or its securing mechanism IMPORTANT Items damaged in trans...

Страница 11: ...cted during transit and or installation Commissioning WARNING Electrical Power Make sure it is safe to apply electrical power to the charger Set the Charger Power By default the QubEV charger is set t...

Страница 12: ...__ Signature _________________________ Date ______________________________ 3 Installers may add their name and the date of installation setting as a record of the work 4 Refit the Charge Control Unit...

Страница 13: ...Light No power to charger or Charger fault Steady Blue Charger available and ready to be connected to vehicle Flashing Blue Connection is okay Steady Green Charging Flashing Green Charging complete S...

Страница 14: ...a functional test of the switchgear if installed every six months by pressing the test button and making sure that the switchgear deactivates x If the equipment fails the test isolate the equipment an...

Страница 15: ...orage incorrect installation accident inappropriate use or cleaning of the SURGXFW UHORFDWLRQ RI WKH SURGXFW DIWHU LWV UVW LQVWDllation abuse misuse or if it has been used or PDLQWDLQHG LQ D PDQQHU QR...

Страница 16: ...British by Design SIMPLE COMPACT AFFORDABLE Images are for marketing purposes only and are not contractual...