background image

QUATRO        

Air Technologies Inc. 

----------------------------------------------------------------

 Engineers Of Clean Air

 ----------------------------------------------------------------

 

30 Hymus Boulevard, Montreal, Quebec, H9R 1C9     Tel.: (514) 630-4444   Fax: (514) 630-4454   website: 

www.quatroair.com

   [email protected] 

RESETTING MICROPROCESSOR CONTROLLER AFTER REPLACING MOTORS 

Resetting Microprocessor After Motor Replacement   WHILE “Service Motor(s)” Led is SOLID 

1-  Ensure motor access door is closed 
2-  Plug power back to the unit 
3-  When you Press “POWER”, MOTOR WILL START, “Service Motor(s)” Led stays SOLID 
4-  While motor is operating, press & hold SPEED UP & DN simultaneously until unit BEEPS 
 

(hold for 10+ seconds, when beeping continuously, release) 

5-  In this condition, “System ON” Led is FLASHING, “Service Motor(s)” led is SOLID 
6-  Press SPEED DN (once) until “Service Motor(s)” Led is FLASHING and system is BEEPING continuously 
7-  Press & HOLD POWER button while “Service Motor(s)” is FLASHING & BEEPING continuously 
 

Release, when it stops BEEPING, and motor operates in LOW speed 

8-  Operate unit at LOW SPEED for 10-15 minutes to break-in new brushes (to prolong brush life) 
 

Resetting Microprocessor After Motor Replacement,  

WHILE “Service Motor(s) Led is OFF 

1-  Ensure motor access door is closed 
2-  Plug power back to the unit 
3-  When you Press “POWER”, MOTOR WILL START 
4-  While motor is operating, press & hold SPEED UP & DN simultaneously until unit BEEPS 
 

(hold for 10+ seconds, when beeping continuously, release) 

5-  In this condition, “System ON” Led is FLASHING 
6-  Press SPEED DN (once) until “Service Motor(s)” Led is FLASHING 
7-  Press & HOLD POWER button while “Service Motor(s)” is FLASHING 
 

Release, when it stops BEEPING, and motor operates in LOW speed 

8-  Operate unit at LOW SPEED for 10-15 minutes to break-in new brushes (to prolong brush life) 
 
Unplug POWER cord from unit, Replace motor(s) as per instructions above, close motor access door. 

MOTOR WILL DEFAULT TO LOWEST SPEED AFTER A RESET. YOU WILL PROLONG MOTOR BRUSH LIFE IF YOU BREAK THEM IN, SO  IT IS ADVISED TO LET MOTOR 
OPERATE AT LOWEST SPEED FOR 15 MINUTES

 

TROUBLESHOOTING, MECHANICAL GUIDE 

Symptoms

 

Possible Cause

 

Suggested Solution

 

Unit will not start 

  Faulty power supply 

  Circuit breaker popped 

  Motor burnt 

  Brushes worn 

 

Check breaker box 

 

RESET circuit breaker on unit panel 

 

Replace motor (PN: AB001) 

 

Replace Brushes (PN: AB112) 

Excessive noise 

  Turbine impeller contacting housing 

 

Replace motor (PN: AB001) 

Insufficient airflow 

  Obstruction in system 

  Clogged filter 

 

Remove obstruction 

 

Replace filter 

Motor shuts off 

  Input amperage too high 

  Graphite crystal rods are consumed 

  Motor is burnt 

 

Ensure filter is in place, reset circuit breaker 

 

Replace rods (PN: AG112, 2/pkg) 

 

Replace motor (PN: AB001) 

Excessive airflow 

  Filter not in place 

 

Install filter 

Suction varies from workstation to workstation 

  Hose lengths between stations vary 

 

Adjust damper or blast gate at each station equalizing suction 

WARRANTY 

QUATRO Air Technologies (QUATRO) warrants its equipment to be free from defect in material and workmanship under 
normal use and service for a period of one year from date of shipment.  QUATRO's obligation under this warranty shall be 
limited to replacing any parts, thereof, which shall be demonstrated to have been defective.  This is expressly in lieu of all 
other warranties, express or implied, including the warranties of merchantability and fitness. 
QUATRO claims no warranty as to merchantability or as to the fitness of the merchandise for any particular use and shall not 
be liable for any loss or damage.  No person, firm or corporation is authorised to assume for QUATRO any other liability in 
connection with the sale of these goods.  Equipment, parts and material manufactured by others and incorporated in 
QUATRO's equipment are warranted by QUATRO only to the extent of the original manufacturer's liability to QUATRO. 
Conditions and Limitations:    

This warranty does not cover

 abuse, misuse, maintenance negligence, improper assembly, 

acts of vandalism, acts of God, fear wear, modifications of the equipment or installation of a part not recommended by 
QUATRO, as well as operation of the equipment at voltages other than those specified by QUATRO

REPLACEMENT PARTS LIST 

 

PowerStation 6 

Description 

PS625-23A6GH 

HEPA Filters (2 required)  

F022 

WHITE Filter Bags (6 required) 

AG149 (pak of 6) 

YELLOW Filter Bags (6 required) 

AG259-06 (pak of 6) or AG259-12 (pak of 12) 

Blower Turbine Assy 230V (2 required) 

(2) AB045-25 

Содержание PowerStation PS6 Series

Страница 1: ... dia use thick gaskets around Rubber hose Fittigns to make up the dimension Your option to install unit on 6 stationery rubber feet or 4 mobile casters install 2 lockable casters in front 1 Install Rubber feet or casters 2 Open filter door remove plastic around HEPA filter install HEPA filter Grating and filter bags 3 Plug Power Cord to a grounded 240 volt wall outlet 4 Connect to individual works...

Страница 2: ...ck Easy Remote Start Stop Valves that reduce Dust Collector power consumption ASVs allow more suction to the active workstations by diverting air from the idle ones Principle of Operation 1 START STOP dust collector when you OPEN CLOSE valve 2 CLOSE valve when not using workstation OPEN valve when using dust collector 3 Install as many ASVs as you like Dust collector STARTS automatically if AT LEA...

Страница 3: ...pect concealed damages inside the box indicate so on the transport companies shipping documents Single box c w all components required either on or inside the unit PRE START UP CHECKLIST a Check that all internal components are present and are adequately supported b Check that labels and serial numbers are present for future identification c Verify power supply compatibility with equipment 120 vol...

Страница 4: ... will be OFF and unit will be ready to operate again Resetting Microprocessor After Filter Replacement WHILE Service Filters Led is OFF 1 Ensure motor access door is closed 2 Plug power back to the unit 3 When you Press POWER MOTOR WILL START 4 While motor is operating press hold SPEED UP DN simultaneously until unit BEEPS hold for 10 seconds when beeping continuously release 5 In this condition S...

Страница 5: ...ower supply Circuit breaker popped Motor burnt Brushes worn Check breaker box RESET circuit breaker on unit panel Replace motor PN AB001 Replace Brushes PN AB112 Excessive noise Turbine impeller contacting housing Replace motor PN AB001 Insufficient airflow Obstruction in system Clogged filter Remove obstruction Replace filter Motor shuts off Input amperage too high Graphite crystal rods are consu...

Страница 6: ...oming Urgent Replace Filters See Filter Service Replacement For More Info Continued Operation May Result In Unit Shutdown High Pressure Causes Excess Motor Heat Accelerates Brush Wear Flashing Slowly Beep Every Second Critical Pressure Unit Has Shutdown To Prevent Damage From Excess Pressure Verify Blockage Remove Blockage Verify All Filters Clean Replace Filters Accordingly See Filter Service Rep...

Отзывы: