background image

QUATRO

 

Air Technologies Inc. 

 
 

----------------------------------------------------------------

Engineers Of Clean Air

----------------------------------------------------------------

 

30 Hymus Blvd., Pte-Claire, Quebec, Canada H9R 1C9    Tel.:(514)630-4444   Fax:(514)630-4454   

www.quatroair.com

    [email protected]

 

2

OPERATING INSTRUCTIONS

 

a)  Connect 1-½” dia. hose to inlet on top of unit. 
b)  Connect other end to your 1.5” dia connection 
c)  Plug-in the power cord to both Dust Collector / Purifier Control Panel and 115-volt wall outlet. 
d)  Start unit by pressing Hand-Switch or Foot-Pedal. 

EQUIPMENT MAINTENANCE (in order from top to bottom) 

Filter Bags:

 When you notice a significant drop in suction, it is time to change the filter bag.  Do not try to clean filter 

bag as this will result in tear.  To replace Filter Bag, unhinge top cap of unit and remove cap.  Slide the bag inlet off the 
inlet pipe and replace. 

Perforated Metal Grille:

 MUST be placed between the filter bag and the filter below it.  When filter fills with debris, 

Perforated grille prevent debris in filter bag from blocking the filter below it. 

Odor Filter (For Dust & Odor Applications):

 Ensure this is always placed on top of HEPA filter. 

HEPA Filer:

 This is the most efficient filter and must be installed LAST, and just above the motor section. 

Box Filter: 

All-in-one box filter for lower debris, higher odor applications (consult with factory)

 

 

WARNING:  DO NOT OPERATE UNIT UNLESS FILTER IS IN PLACE, AS MOTOR MAY BURN-OUT.

 

 

 

  

 

 
 

BLOWER MAINTENANCE 

Refer to following figure when performing this procedure. 

   

 

 

 

 

 

Note the orientation of the bracket. 

 

 

CAUTION: 

ALLOW MOTOR(S) TO COOL FOR 45 MINUTES BEFORE SERVICING. 

        Filter Bag                      Perf Spacer                            Odor Filter                               HEPA Filter                      Box Filter 
  

A . Retaining nuts (4X) 
B . Motor-to-bracket, mounting screws (4x) 
C . Black wire terminal 

. Green wire terminal  

. White wire terminal 

F .   Motor retaining bracket 
 
1. Unplug power cord and open motor access panel 
 
2. Disconnect wires (C, D,E), cut zip ties 
 
3. Remove the retaining nuts (A) and lock washer holding 
the motor assemblies 
 
4. Remove the motor retaining bracket (F) from the old 
motor by removing the 4 mounting screws (B) 
 
5. Install the bracket on the new motor. See the 
installations pictures below. 

Содержание Basic K1

Страница 1: ...ct concealed damages inside the box indicate so on the transport companies shipping documents SAFETY PRECAUTIONS Carefully read instructions in this manual before operation keep manual as it contains information for proper operation and maintenance Keep all fastening hardware tight to ensure that the unit is in safe working condition Familiarise yourself with the way in which the special filter is...

Страница 2: ...from blocking the filter below it Odor Filter For Dust Odor Applications Ensure this is always placed on top of HEPA filter HEPA Filer This is the most efficient filter and must be installed LAST and just above the motor section Box Filter All in one box filter for lower debris higher odor applications consult with factory WARNING DO NOT OPERATE UNIT UNLESS FILTER IS IN PLACE AS MOTOR MAY BURN OUT...

Страница 3: ...10 Consult factory for 230v parts OPTIONALLY AVAILABLE REMOTES AA011 Hand Switch AA012 2 Station Hand Switch AA224 2 Station Foot Pedal WARRANTY QUATRO Air Technologies warrants its equipment to be free from defect in material and workmanship under normal use and service for a period of one year from date of shipment QUATRO s obligation under this warranty shall be limited to replacing any parts t...

Страница 4: ...ended for use with explosive highly flammable or toxic substances orenvironments Example where the lower flammability limit may be exceeded see chemicals specific MSDS for more information on these limits 3 If you are collecting a flammable material it is your responsibility to ensure that an ignition source is not introduced into the collected material This could be in the form of static discharg...

Отзывы: