![Quatech QSC(LP)-100 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/quatech/qsc-lp-100/qsc-lp-100_user-manual_771408008.webp)
2.3 Force High-Speed UART Clock (X2, X4, or X8, J3-J5)
These jumpers force an increase of the UART input clock frequency by a
factor of two, four, or eight. This feature can allow legacy software to use baud
rates above 115,200 bits per second. It is also useful if the serial port device
driver does not directly support setting the higher baud rates through the Options
Register (see section 4.4).
If one of these jumpers is applied, it overrides any value written to the
Options Register to set the clock multiplier by software. The effective baud rate
will be either two, four, or eight times the value for which the UART itself is
programmed.
The factory default is none of these jumpers applied, which allows for
software control of the clock multiplier via the Options Register. The Options
Register powerup default is for a standard times-1 clock of 1.8432 MHz for
compatibility with standard serial ports.
SPAD
X2
X4
X8
J2
J3
J4
J5
Force times-eight clock
Baud rates up to 921.6 kbps
SPAD
X2
X4
X8
J2
J3
J4
J5
Force times-two clock
Baud rates up to 230.4 kbps
SPAD
X2
X4
X8
J2
J3
J4
J5
Factory default
software control
SPAD
X2
X4
X8
J2
J3
J4
J5
Force times-four clock
Baud rates up to 460.8 kbps
Figure 4 --- Clock multiplier jumper options
QSC(LP)-100 User's Manual
8