Troubleshooting
100-8006-152G AirborneDirect™
Serial Bridge User’s Guide
Page 73
Quatech, Inc. Confidential
LED TROUBLESHOOTING
The following table provides LED troubleshooting suggestions.
Table 12. Indicator LED Troubleshooting
If the…
Perform These Tasks…
Power
LED does not turn
On
.
Check power connector is properly inserted.
Power
LED turns
Red
.
Remove power and re-apply. If the Power LED
remains Red, contact Quatech, Inc.
Power
LED is
Amber
.
Bridge has not established an IP address either
through DHCP or Static methods.
DHCP is the default method by which the unit
obtains an IP address. Your network must have a
DHCP server available when the bridge is powered-
up. Most AP/Routers have a DHCP server built-in.
Enable your DHCP server and re-start the module.
Link
LED continues to
Blink Red
.
Bridge has not found an Access Point with which to
associate. Be sure the Access Point you want to
use is turned on and has WEP and WPA disabled
(you can enable WEP or WPA after the Bridge has
been configured).
If this does not help, be sure there are no nearby
devices causing interference. If there are, either turn
off or move the device causing the interference or
move the Bridge and Access Point to another
location.
Comm
LED is
Off
or
Amber
.
Be sure a serial device is connected to the Bridge
and that the device is turned on.
Comm
LED is
Red
and
Link
LED is
Green
but you are unable to pass
data.
No open TCP socket is recognized by the Bridge.
Be sure you have an open TCP connection to the
bridge and the connection is in data pass mode.