![Quasonix QSX-RDMS Series Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/quasonix/qsx-rdms-series/qsx-rdms-series_installation-and-operation-manual_771364014.webp)
Page13 of 21
MO
Modulation
Report or set modulation setting.
Examples:
MO
Report the modulation setting
MO 0
Set modulation to PCM/FM
MO 1
Set modulation to SOQPSK-TG
MO 2
Set modulation to Multi-h CPM
MO 3
Set modulation to PSK
BR
Bit Rate
Report or set baseband bit rate
Examples:
BR
Report the bit rate setting
BR 20
Set bit rate to 5 Mbps
BR 0.6
Set bit rate to 600 Kbps
DP
Data Polarity
Report or set data polarity inversion state
Examples:
DP
Report the polarity inversion state
DP 0
Set data inversion off
DP 1
Set data inversion on
CP
Clock Polarity
Report or set clock polarity inversion state
Examples:
CP
Report the clock source state
CP 0
Set clock inversion off
CP 1
Set clock inversion on
GO
Start/Restart
Initiate demodulation with current parameters
RE
Restart
Demodulator
Restart Demodulator without reconfiguration
SC
Saturation Count
Report the saturation count
PL
Input Power Level Report current input power level
VL
Verbosity Level
Report or set verbosity level, on a scale of 0 – 9.
Examples:
VL
Report the verbosity level
VL 0
Set the verbosity level to 0
VL 5
Set the verbosity level to 5
BM
Bit rate
Measurement
Report bit rate measurement
SV
Save Parameters
(Requires NV
option)
Saves the current parameters in non-volatile
memory, including frequency, modulation, bit rate,
data polarity, clock polarity, AGC state, verbosity
level, etc.
RV
FPGA &
Firmware
Revision
Report the revision numbers for both the FPGA
load and the Firmware load
Table 4. Legacy PSK Basic Serial Commands.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com