nanoTX
TM
Telemetry Transmitter
54
Quasonix, Inc.
Mnemonic
Command
Name
Description
Option (s)
Required
Setting
Saved?
Factory
Default
SM
Modulation
Sweep
Sweeps the transmitter
modulation between the provided
limits with the provided step size
at a fixed rate
Examples:
SM
Toggle sweep ON/OFF
with current values
SM ?
Displays current sweep
state
SM start stop step msec
start = low index
stop = high index
step = index step size
msec = milliseconds between
steps
MS
N
SM
Disabled
SN
Serial/Part
Number
Report the serial number and part
number for the unit
Standard
N/A
N/A
SS
Show Settings
Displays most of the common
device settings in one compact
display
Standard
N/A
N/A
SV or SA
(or PS or
PW)
Save
Configuration
Saves the current transmitter
configuration to a user-selected
preset number, from 0 to 15
where 0 is the power-on default
unless hardware presets are
enabled
The SV command also allows the
user to assign an alias to the
desired preset.
Examples:
SV 1
Save current
configuration to preset 1
SV 7 xyz
Save current
configuration to preset 7 and
assign alias name “xyz”
*Refer to SV Note below for
exception
Standard
N/A
N/A