nanoTX
TM
Telemetry Transmitter
47
Quasonix, Inc.
Mnemonic
Command
Name
Description
Option (s)
Required
Setting
Saved?
Factory
Default
ID
Internal Data
Gen
Report or set the internal data
pattern
This setting is used if the Data
Source is set to internal (DS 1)
and the Clock Source is set to
internal (CS 1).
When setting the data, the
argument must be “PN6” (or
“PN06”), “PN11”, “PN15”, or
“PN23”, or a valid 4 digit
hexadecimal value.
Examples:
ID
Report the internal data
pattern
ID PN15
Set internal data
pattern to PN15
ID AA55
Set internal data
pattern to 0xAA55
In SOQPSK mode, ID 5555 or ID
AAAA will result in an
unmodulated carrier, at the
nominal carrier frequency.
Note: If the CP07 option is
present, the input argument does
not include the “PN” and a
hexadecimal value requires the
addition of a leading “x”, as shown
in the following example.
CP07 Examples:
ID
Report the internal data
pattern
ID 15
Set internal data pattern
to PN15
ID xAA55
Set internal data
pattern to 0xAA55
Standard
Y
ID PN15
IMN
Internal Model
Number
Display the internal model
number for the transmitter
Standard