Quartz M320 Скачать руководство пользователя страница 4

1. Set the rotary switch to 

 range. 

2. Connect the test leads to the circuit or resistor being measured and 
read the displayed value. 

 

Diode Test 

1. Set the rotary switch to 

  range. 

2.  For  forward-bias  readings  on  any  semiconductor  component,  place 
the  red  test  lead  on  the  component's  anode  and  place  the  black  test 
lead on the component's cathode. 
3. The meter will show the approx. forward voltage of the diode 

   

Audible Continuity Test 

1. Set the rotary switch to

  range. 

2.  Connect  the  test  leads  to  the  resistance  in  the  circuit  being 
measured. 
3. When the test lead to the circuit is below 50

, a continuous beeping 

will indicate it. 

 

KEY FUNCTION 
Hold Key 

Data  Hold  mode  makes  the  meter  stop  updating  the  display.  Enabling 
Data  Hold  function  in  auto  range  mode  makes  the  meter  switch  to 
Manual ranging mode, but the  full-scale  range  remains the  same. Data 
Hold  function  can  be  cancelled  by  changing  the  measurement  mode, 
pressing 

RANGE

 key, or push 

HOLD

 key again. 

To enter and exit the Data Hold mode:   
1. Press 

HOLD

 key (short press). Fixes the display on the current value, 

DH

 

is displayed. 

2. A second short press returns the meter to normal mode. 

Select Key 

1. Switches between dc and ac voltage or current. 

2. Disables automatic power-off feature.

 

BATTERY SAVER 

The Meter enters the "sleep mode" and blanks the display if the Meter is 

on but not used for 30 minutes. 
Press the 

HOLD

 key or rotate the rotary switch to wake the meter up.   

To  disable  the  Sleep  mode,  hold  down  the 

SELECT

  function  key  while 

turning the meter on. 

 

BEEPER INDICATION 

When press the function key and if it is valid, a beep will be emitted. The 
buzzer  will  sound  five  times  one  minute  before  auto  power  off.  And  a 
long  sound  to  show  the  auto  power  off.  In  the  continuity  measuring 
status, if the resistance is smaller than 50

Ω

,the buzzer will sound. 

 

BATTERY & FUSE REPLACEMENT 

To replace the Meter's battery: 
If  the  sign  "BATT"  appears  on  the  LCD  display,  it  indicates  that  the 
battery  should  be  replaced.  Remove  the  screw  on  the  back  cover  and 
open  the  battery  case.  Replace  the  exhausted  batteries  with  two  new 
1.5V batteries of the same type (SR44). 

To replace the Meter's fuse: 

Fuse rarely need replacement  and blow  almost  always  as  a result  of 
operator

s  error.  Open  the  case  and  replace  the  blown  fuse  with  the 

same rating specified: F 500mA /250V 

5

×

20. 

 

WARNING! 

Before attempting to open the case, always be sure that test leads have 
been  disconnected  from  measurement  circuits.  Close  case  and  tighten 
screws  completely  before  using  the  meter  to  avoid  electrical  shock 
hazard. 

 

ACCESSORIES     

Battery            1.5V 

(

SR44)        2           

Carrying Case                              1 
Operating manual                        1 

                                                                                        WLS040     

>>>6 

7<<< 