Overload protection: 600V dc or 600V ac rms.
Diode Test
Function
Range
Resolution
Accuracy
Diode Test
1 V
0.001V
1.0% uncertainty
Overload protection: 600V dc or 600V ac rms.
Test Condition: Forward DC current approximately 1mA. Reversed DC
voltage approximately 1.5V.
Continuity Check
Function
Range
Resolution
Description
Continuntiy Test
400
Ω
0.1
Ω
Continuity beeper
≤
50
Ω
Overload protection: 600V dc or 600V ac rms.
Test Condition: Open circuit voltage: approx. 0.5V
WITH AUTO POWER OFF FUNCTION
GENERAL SPECIFICATIONS
Environment conditions:
600V CAT. II
Pollution degree: 2
Altitude < 2000m
Operating temperature: 0~40
℃
(32
℉
~122
℉
)
Storage temperature: -10~60
℃
(14
℉
~140
℉
)
MAX. Voltage between terminals and earth ground: 600V AC rms or
600V DC.
Fuse Protection: F 500mA/250V
∅
5
×
20.
Sample Rate: 3 times/sec for digital data.
Display: 3999 LCD display. Automatic indication of functions and
symbols.
Range selection: automatic.
Over Range indication: LCD will display "OL".
Low battery indication: The "
BATT
" is displayed when the battery is
under the proper operation range.
¥
Polarity indication: "
−
" displayed automatically.
¥
Power source: 3V
¥
Battery type: SR44.
¥
Dimensions: 120(L)
×
70(W)
×
18(H) mm.
¥
Weight: 110g. Approx. (battery included).
OPERATING INSTRUCTION
Voltage Measurement
1. Set rotary switch to the V range.
2. Press the
SELECT
key to select DCV or ACV measuring mode.
3. Connect the black and red test leads to the circuit being measured
4. Read the displayed value. The polarity of red test lead connection
will be indicated when making a DCV measurement.
Current Measurement
1. Turn off power to the circuit. Discharge all high voltage capacitors.
2. Set the rotary switch to the mA range.
3. Press the
SELECT
key to select DCA or ACA measuring mode.
4. Break the circuit path to be tested.
Touch the black probe to the more negative side of the break; touch
the red probe to the more positive side of the break. (Reversing the
leads will give a negative reading, but will not damage the Meter.)
6. Turn on power to the circuit; then read the display.
7. Turn off power to the circuit and discharge all high voltage capacitors.
Remove the Meter and restore the circuit to normal operation.
Capacitance Measurement
1. Set the rotary switch to
range.
2. Connect the test leads to the capacitor being measured and read
the displayed value.
Resistance Measurement