3. Vent Placement on Ridge

Attach vent to the roof deck by driving a nail in 
each of the two corners on both ends of the vent. 
Also, drive two nails through the vent and foam 
end  cap  to  hold  foam  in  place  on  the  ends  of 
the ridge only. Nails should penetrate the wood 
roof  deck  at  least 

3⁄4”

.  It  is  not  recommended  to 

nail vent to ridge prior to cap shingle installation. 
Because  of  the  popularity  of  dimensional 
roofing  material  such  as  the  newer  40/50  year 
and  lifetime  laminated  shingles,  we  require 
that  a  bead  of  sealant  be  applied  to  the  roof 
shingles  before  installing  the  vent  on  the  ridge. 

This  sealant  should  fill  any  voids  between  the 
bottom of the vent and the surface of the shingle. 
Use  either  butyl sealant conforming to ASTM C1085, 
latex sealant conforming to ASTM C834, silicone 
sealant  complying  with  ASTM  C920  or  asphalt 
roofing  cement  complying  with  ASTM  D4586. 
Roll  out  or  place  Quarrix  Ridge  Vent  along  the 
entire length of slot also covering the 6” minimum 
uncut  ridge  on  both  ends.  Bend  vent  into  a  “V” 
Shape.  Secure  at  the  lead  edge  after  inserting
the end cap. 

Nail  should  penetrate  roof  deck  a  minimum  of 

3⁄4”

. Pull the vent tight and secure at about 10’. Pull 

the rest of the vent tight and secure, inserting the 
end cap. Multiple lengths of vent can be joined 
by butting the sections tightly together. End caps 
should  be  inserted  at  the  beginning  and  end 
of  each  section.  Do  not  pre-fasten  ridge  vent 
along the entire vent; with Quarrix Ridge Vent’s  
One-Pass™  Installation,  it  is  not  necessary  to  
pre-fasten  the  vent  every  2’  to  3’  prior  to  cap  
shingle installation.

INSTALLATION INSTRUCTIONS     

ATTIC PROTECTION

Quarrix.com  

 800.438.2920

1

2

3

2

INST-SSRV01.0

2

.0

4.

21

Содержание StormStop

Страница 1: ...ications a 4 slot should be cut 2 on each side of ridge Aminimumof6 mustbeleftuncutoneachendof theridge Oncetheslotiscutandanyoverlapping shingles covering the ridge are trimmed and removed the ridge is ready for vent installation The amount of ventilation is controlled by the length of slot cut along the roof ridge For the most attractive roofline it is recommended that Quarrix StormStop Ridge Ve...

Страница 2: ...the roof shingles before installing the vent on the ridge This sealant should fill any voids between the bottom of the vent and the surface of the shingle UseeitherbutylsealantconformingtoASTMC1085 latex sealant conforming to ASTM C834 silicone sealant complying with ASTM C920 or asphalt roofing cement complying with ASTM D4586 Roll out or place Quarrix Ridge Vent along the entire length of slot a...

Страница 3: ... has been installed properly if the bottom of the vent is flat on the roof and the peak is slightly rounded Description consult oretimi linam Verehena non tam reste non tus is Quarrix com 800 438 2920 INSTALLATION INSTRUCTIONS ATTIC PROTECTION Using One Pass Installation secure cap shingles and vent at the same time Nail ridge caps with roofing nails in a common overlapping pattern Nails should pe...

Страница 4: ... end of the section Using construction adhesive or sealant caulk coat both sides of the StormStop material where it has been cut back at the end of the vent Insert the foam end cap with the cut back StormStop material between the foam end cap and the underside of the vent to assure a weather tight seal Because of the popularity of dimensional roofing material such as 40 50 year and lifetime lamina...

Страница 5: ...This createsthemostattractiveridgeandhipline Insertthefoamendcapunder the ridge vent where it is at full width Fasten vent for hip at point where it meets ridge Roll out or place the vent all of the way down the hip covering 2 pre laid cap shingles at the bottom of the hip Go back over hip vents and fasten at 4 intervals If the vent is not being run the entire length of the hip use the cap shingle...

Страница 6: ...e foam end cap with the cut back StormStop material between the foam end cap and the underside of the vent to assure a weather tight seal 3 Vent Placement on Ridge Before installing the vent on the ridge a bead of sealant is required between the stone coated steel and the underside of the ridge vent This sealant should fill any voids between the bottom of the vent and the surface of the panel Caul...

Страница 7: ...bottom of the vent is flat on the roof and the peak is slightly rounded Install hip ridge caps per manufacturer s installation guide Each hip ridge piece should clip together by inserting the return at the nose of each piece into the back clip which is located at the top of the hip ridge cap section Fasten cap to vent through thebackclipusing 8screws Fastenersshouldpenetratethroughthewood roof dec...

Страница 8: ...e it has been cut back at the end of the vent Insert the foam end cap with the cut back StormStop material between the foam end cap and the underside of the vent to assure a weather tight seal 3 Vent Placement on Ridge Beforeinstallingtheventontheridge abeadofsealantisrequiredbetween the roof tile and the under side of the ridge vent This sealant should fill any voids between the bottom of the ven...

Страница 9: ...anner meet the requirement for weather blocking according to Concrete and Clay Roof Tile Design Criteria Installation Manual for Moderate Climate Regions ICBO ER 6034P 4 FlatTile ROOFS INST SSRV01 02 04 21 Distributed by Best Materials LLC http www bestmaterials com 1 800 474 757 0 sales bestmaterials com http www bestmaterials com 1 800 474 757 0 sales bestmaterials com http www bestmaterials com...

Страница 10: ...r An end cap should be inserted at the end of each section Note For Class A Installation Only For Class A Quarrix vent installation follow steps 1 2 3 as stated above Once the vent has been installed use a utility knife with a hook blade and remove the corrugated plastic center section of the vent Do this for the hip and ridge This modified installation meets the requirements for UL790 Class A sta...

Страница 11: ...intain the pitch of the roof SHINGLE ROOFS Cedar Shake INST SSRV01 02 04 21 Distributed by Best Materials LLC http www bestmaterials com 1 800 474 757 0 sales bestmaterials com http www bestmaterials com 1 800 474 757 0 sales bestmaterials com http www bestmaterials com 1 800 474 7570 http www bestmaterials com 1 800 474 757 0 sales bestmaterials com http www bestmaterials com 1 800 474 757 0 sale...

Страница 12: ...p material between the foam end cap and the underside of the vent to assure a weather tight seal 3 Vent Placement on Ridge Beforeinstallingtheridgevent abeadofsealantisrequiredbetweenthemetalorfoamclosureand theundersideofthevent fillinganyvoids Caulkingandsealantsshallbesuitableforexterioruseand beresistanttoweathering useeitherbutylorpolyurethanesealants Thecaulkingandthesealants shall be compat...

Страница 13: ...e cap over Quarrix Ridge Vent according to metal manufacturer s installation instructions Metal Roofs INST SSRV01 02 04 21 Distributed by Best Materials LLC http www bestmaterials com 1 800 474 757 0 sales bestmaterials com http www bestmaterials com 1 800 474 757 0 sales bestmaterials com http www bestmaterials com 1 800 474 7570 http www bestmaterials com 1 800 474 757 0 sales bestmaterials com ...

Отзывы: