background image

YOU WILL NEED: 

1. SIM card: 

 

SIM must operate on the GSM (2G) network for this 2G version. 

Check with your SIM 

supplier. 

 

 

Credit on the SIM (we recommend automatic top-ups) 

 

The SIM is not PIN protected 

 

The SIM is set to disable voicemail 

 

Avoid SIM cards that deactivate automatically if the SIM is not used often

 

If your SIM will do this and if your G021/22 is likely to be unused for long periods of time, you 

will have to send the G021/22 an update request periodically to keep the SIM card active. The 
time limit is often three months, check with your operator. 

2. Power supply cable: 

long enough to reach your device in its final location.

 

3. Check there is mobile network reception for your SIM card

 in the location that your device 

will be installed (you can check the SIM card in a mobile phone). 

QK-G021/22 

Blue LED - Network

 

Red LED - System

 

This is an overview only. Familiarize yourself with the manual and the manuals of 
any  connecting  devices  before  installation.  It  is  always  recommended  that 
electronic equipment be installed by an experienced installer. 

 

Red System LED

: will flash at 1 second intervals once the system has finished initialization. The 

LED will not flash while the G022 is processing a command. 

 

Blue Network LED

: LED will flash blue at start up as it is connecting to a network. Once      

connected, the LED will flash much slower, approximately  every 3 seconds. 

The network LED will flash at one second intervals once the registration is completed.  

INSTALLATION 

1. Download and install the app 

for mobile phones. https://www.quark-elec.com/downloads/

apps/ 

2. Select G021/22 location: 

location must be indoors and not exposed to water or high humidity. 

3. Connect the relay output 

(if required): check relay setup for whether you want relays in 

normal open (NO) or normal closed (NC) position.  

4. Connect alarm inputs 

(if required) to the correct terminal: alarm inputs (INT) 1/2 will activate r

elay 1/2 respectively. The G022 is compatible with inputs that send signals as a switch (by closing 
the circuit) and alarm inputs that send a low voltage signal.  

5. Insert your SIM into the G021/22 device 

(make a note of the SIM number first for reference). 

6. Connect to power: 

Check LEDs are working correctly.  

QK-G021/22 

7. Register the main phone number that will control the device within 10 minutes of powering 
up the G021/22 

by texting ‘

888888’ 

from your chosen phone to G021/22 SIM card. If registration 

is successful, the module will reply with ‘

Your phone has been registered

’. If unsuccessful, the 

module will reply with ‘

registered disabled’

. If registration is unsuccessful, repower the device 

and reattempt registration within 10 minutes of powering up the device.  
 
You can add up to three additional control mobile phones (check next page) 
 

OPERATION 

You can now send commands and receive messages by SMS text or the text generating APP. 

 

Automated relay setting for relay 1/ 2 can be changed by adjusting the small jumpers 

inside the enclosure.  

 

Self-lock control: 

When activated, the relay will stay on until it receives a different command. 

 

Latching control: 

When activated, the relay will stay on for a period of seconds, determined 

by the user (3, 6, 9 or 12 seconds). It will then return to its normal state.   

Remember, the device processes one command at a time. Each command will have a reply 
to confirm the command has been received and executed. You must wait for a reply 
message before sending another command. 

All SMS text commands must always be sent 

using CAPITAL letters. Do not add spaces or any other characters. 

When an alarm is triggered, the relay will stay locked ON until you send the 
command “EXTRT” to reset alarm (even if set to latching mode). 

QUICK COMMANDS 

 

To turn relay on

, text  '

DKYn

' (replace 'n' with the relay number). 

 

To turn relay off

, text '

GBYn

' (replace 'n' with the relay number). 

 

To run a relay for a short while

, text 

'ONOFFRnxxx#

'. Replace 'n' with the relay number (1 or 

2) and replace ‘xxx’ with the delay times (from 001 to 999 seconds). This is a one off command 
and will not affect future actions. 

 

To disable text alerts

,  text '

EXTGGn

' (replace 'n' with the relay number). This command dis-

ables the text alert, the external alarm input itself will remain active and will still activate the 
relay, unless the external alarm input itself is disabled. 

              To re-enable text alerts, text '

EXTKKn

' (replace 'n' with relay number).  

 

To disable the external alarm input

, text '

EXTGBn

' (replace ‘n’ with the relay number). 

              To re-enable all external alarm inputs, text '

EXTRT

'. 

 

To change the SIM number of main control phone

, text '

XGZHM

' from the current main con-

trol phone. The new phone must be registered within the next 10 minutes. 

 

To add an additional mobile number

, text '

BDn(mobile number)F

', replacing 'n' with '1', '2' or 

'3' according to a number of an additional mobile device. 

 

    Daily timer settings: 

Relays 1 and 2 support a daily timer function. This is useful for turning the 

relays on and off without having to message the device. The relays will switch ON/OFF daily 
according to the timer settings. Check the manual for further instructions. 