background image

 
 

QK-A034 Manual 

 

V 2.0 

9 of 16 

2020 

 

VTG* 

Course Over Ground and Ground Speed 

129026 

VWR 

Relative (Apparent) Wind Speed and Angle 

130306 

XTE 

Cross Track Error, Measured 

129283 

ZDA 

Time & Date 

126992 

VDM 

AIS Message 1,2,3 

129038 

VDM 

AIS Message 4 

129793 

VDM 

AIS Message 5 

129794 

VDM 

AIS Message 9 

129798 

VDM 

AIS Message 14 

129802 

VDM 

AIS Message 18 

129039 

VDM 

AIS Message 19 

129040 

VDM 

AIS Message 21 

129041 

VDM 

AIS Message 24 

129809. 129810 

Please note: some PGN sentences that are received require additional data before being sent. 

2.5.2.  NMEA 2000 to NMEA 0183 conversions 

The following NMEA 2000 to NMEA 0183 conversions are currently supported. 
 

NMEA 2000 PGN 

HEX code 

Function 

Converted to NMEA 0183 Sentences 

126992 

1F010 

System Time 

ZDA 

127245 

1F10D 

Rudder 

RSA 

127250 

1F112 

Vessel Heading 

HDG, VHW 

127251 

1F113 

Rate of Turn 

ROT 

127258 

1F11A 

Magnetic Variation 

HDG 

128259 

1F503 

Speed, Water referenced 

VHW 

128267 

1F50B 

Water Depth 

DBT, DPT 

128275 

1F513 

Distance Log 

VLW 

129025 

1F801 

Position, Rapid Update 

GLL 

129026 

1F802 

COG & SOG, Rapid Update 

VTG 

129029 

1F805 

GNSS Position Data 

GGA, GLL, GSA, RMC, ZDA 

129033 

1F809 

Time & Date 

ZDA 

129044 

1F814 

Datum 

DTM 

129283 

1F903 

Cross Track Error 

APB, RMB, XTE 

129284 

1F904 

Navigation Data 

RMB 

129291 

1F90B 

Set & Drift, Rapid Update 

VDR 

129539 

1FA03 

GNSS DOPs 

GSA 

129540 

1FA04 

GNSS Sats in View 

GSV 

130306 

1FD02 

Wind Data 

MWV 

130310 

1FD06 

Environmental Parameters 

MDA, MTW 

130311 

1FD07 

Environmental Parameters 

MDA 

130312 

1FD08 

Temperature 

MDA, MTW 

129038 

1F80E 

AIS Message 1,2,3 

VDM 

129793 

1FB01 

AIS Message 4 

VDM 

129794 

1FB02 

AIS Message 5 

VDM 

129798 

1FB06 

AIS Message 9 

VDM 

129039 

1F80F 

AIS Message 18 

VDM 

129040 

1F810 

AIS Message 19 

VDM 

129809 

1FB11 

AIS Message 24 (Part A) 

VDM 

129810 

1FB12 

AIS Message 24 (Part B) 

VDM 

Please note: some PGN sentences that are received require additional data before being sent. 

Содержание QK-A034

Страница 1: ...s to NMEA 0183 sentences NMEA 0183 to NMEA 2000 converter converts common sentences to PGNs and visa versa WiFi Ad hoc mode allows up to 4 connections to the internal WiFi module simultaneously WiFi Station mode allows for the connection of the A034 to your router access point for greater number of wireless users and WiFi range WiFi Standby option disable WiFi WiFi and USB input and output of comb...

Страница 2: ...6 1 WiFi Ad hoc mode connection 10 2 7 USB Output 11 2 7 1 Will a driver be needed to connect via USB 11 2 7 2 Checking the USB connection Windows 11 3 Configuration via USB 12 3 1 Configuring Baud Rates 12 3 2 WiFi Station mode 13 3 3 WiFi Standby Disable 13 3 4 Filtering 14 3 4 1 Configuring filters 14 3 4 2 Routing data away from chosen outputs 14 3 5 USB Monitoring NMEA Messages 15 4 Upgrading...

Страница 3: ...n the listener portsand sends this data to NMEA 2000 output port WiFi interface and USB Bi directional WiFi the A033 allows for wireless connection to autopilots and other NMEA devices if desired Data from instruments is available wirelessly though WiFi connections giving complete freedom to navigate monitor and control from anywhere on board Up to 4 connections from iPads iPhone Android phones an...

Страница 4: ... is water resistant the terminals are open and seawater can cause a short circuit A034 comes with an extruded aluminium enclosure with external dimensions of 114 5 x 110 x 32 mm The A034 should be mounted in a dry place such as behind the instrument panel on a flat surface Ensure there is enough space around the multiplexer to connect the wirings Figure 1 Dimensions ...

Страница 5: ...tion The A034 multiplexer has the following options for connection to inputs outputs and host devices NMEA 2000 input and output WiFi input and output USB input and output 3x NMEA 0183 inputs 1x SeaTalk1 input Figure 1 Side view drawing Power off all the devices before connecting ...

Страница 6: ...ured to pass or block specific sentences from the input devices See the Configuration section A034 combines these filtered NMEA 0183 inputs with the NMEA sentences converted from the SeaTalk input into one NMEA0183 serial data stream NMEA baud rates are set to the following default settings NMEA IN 1 4800 bps NMEA IN 2 4800 bps NMEA IN 3 38400bps These can be adjusted as required using the Configu...

Страница 7: ...connects all instruments The A034 SeaTalk to NMEA converter works in one direction only NMEA sentences are not converted to SeaTalk Supported SeaTalk1 Datagrams SeaTalk NMEA Description 00 DBT Depth below transducer 10 MWV Wind angle 10 and 11 combined 11 MWV Wind speed 10 and 11 combined 20 VHW Speed through water includes heading when present 21 VLW Trip mileage 21 and 22 combined 22 VLW Total m...

Страница 8: ...g all NMEA 0183 messages received and NMEA 0183 messages converted from the NMEA 2000 network WiFi USB inputs are NMEA 0183 messages and are converted to NMEA 2000 for the NMEA 2000 bus The following is a typical PCDIN message format outputted through WiFi and USB The chart software will convert this into more meaningful information Received message PCDIN 01F119 00000000 16 0064050800FFFF0C 5B Hea...

Страница 9: ...Turn ROT 127258 1F11A Magnetic Variation HDG 128259 1F503 Speed Water referenced VHW 128267 1F50B Water Depth DBT DPT 128275 1F513 Distance Log VLW 129025 1F801 Position Rapid Update GLL 129026 1F802 COG SOG Rapid Update VTG 129029 1F805 GNSS Position Data GGA GLL GSA RMC ZDA 129033 1F809 Time Date ZDA 129044 1F814 Datum DTM 129283 1F903 Cross Track Error APB RMB XTE 129284 1F904 Navigation Data R...

Страница 10: ...er anywhere on your local area network Increasing the WiFi range Similar to plugging the device directly into the router but using wireless technology In this way the mobile devices receive both your marine data and other AP connections such as Internet WiFi can also be disabled in Standby mode This reduces power consumption and may be required when connecting 2 WiFi transmitting devices 2 6 1 WiF...

Страница 11: ...ll automatically if your device is running an original Windows 10 version A new COM port will automatically show up in the device manager once powered and connected via USB The A034 registers itself to the computer as a virtual serial com port If the driver does not install automatically it can be found on the included CD and downloaded from www quark elec com 2 7 2 Checking the USB connection Win...

Страница 12: ... applications using the A034 when using the configuration tool Figure 3 Configuration tool connection Once open click Connect When A034 is connected to a computer Windows system and powered up A034 connected will be shown at the centre of the bottom and the software version shows at the bottom right Press Config once you have set the Baud rates for the inputs to save them to the A034 Then press th...

Страница 13: ...0 and 255 This number must not be used by any other equipment connected to your router 8 Enter your router s IP address in the Gateway section This can usually be found under the router Leave the other settings as they are 9 Click Config in the bottom right hand corner and wait 60 seconds After 60 seconds Click Disconnect 10 Repower the A034 and it will now attempt to connect to the router In your...

Страница 14: ...ed for other devices data Most of Chart plotters also have their own sentence filter however many PC mobile phone based applications do not So using the black list to filter un necessary sentences is very helpful Filtering also removespotential conflict if two similar NMEA devices provide the same sentence type Users may choose to enable this data on one input only filtering and to transmit to the...

Страница 15: ...ftware 3 Ensure the configuration tool is connected to the A034 and then click Ctrl F7 4 A new Window will pop up with a drive named STM32 or similar Copy the firmware into this drive and wait around 10 seconds to make sure the full file has been copied 5 Close the window and the Configuration software 6 Re power the A034 then the new firmware will be active 5 Specification Item Specification DC s...

Страница 16: ...sed to augment normal navigational procedures and practices It is the user s responsibility to use this product prudently Neither Quark elec nor their distributors or dealers accept responsibility or liability either to the products user or their estate for any accident loss injury or damage whatsoever arising out of the use or of liability to use this product Quark products may be upgraded from t...

Страница 17: ...ll not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the eq...

Отзывы: