Quantum Turret 6 Скачать руководство пользователя страница 2

2

 

 

TABLE

 

OF

 

CONTENTS

 

 

Table

 

of

 

Contents

 

....................................................................................................................................

 

2

 

1.

 

GETTING

 

STARTED

 

...........................................................................................................................

 

3

 

A.

  

YOUR

 

SHIPMENT

 

WILL

 

CONTAIN:

 

..................................................................................................

 

3

 

Turret

 

6

 

package

 

..............................................................................................................................

 

3

 

B.

  

DEPENDING

 

ON

 

YOUR

 

ORDER,

 

THE

 

SHIPMENT

 

MAY

 

ALSO

 

CONTAIN:

 

..........................................

 

3

 

BATH

 

10

 

...........................................................................................................................................

 

3

 

T

App

 

software

 

................................................................................................................................

 

3

 

C.

  

SYSTEM

 

SETUP

 

................................................................................................................................

 

4

 

D.

  

SOFTWARE

 

INSTALLATION

 

.............................................................................................................

 

4

 

E.

  

SYSTEM

 

OPERATION

 

.......................................................................................................................

 

4

 

2.

  

Using

 

the

 

MenU

 

BUTTON

 

...................................................................................................................

 

6

 

3.

  

Features

 

of

 

the

 

Turret

 

6

 

.....................................................................................................................

 

8

 

A.

  

GENERAL

 

DESCRIPTION

 

..................................................................................................................

 

8

 

B.

  

CUVETTE

 

HOLDER

 

...........................................................................................................................

 

9

 

C.

  

CUVETTE

 

Z

HEIGHT

 

.........................................................................................................................

 

9

 

E.

  

COOLING

 

WATER

 

FOR

 

THE

 

PELTIER

 

..............................................................................................

 

10

 

F.

   

DRY

 

GAS

 

TO

 

MINIMIZE

 

CONDENSATION

 

.....................................................................................

 

11

 

G.

  

EXTERNAL

 

TEMPERATURE

 

PROBE

 

................................................................................................

 

11

 

H.

  

EXTERNAL

 

COMPUTER

 

CONTROL

 

.................................................................................................

 

11

 

4.

  

Error

 

Codes

 

.......................................................................................................................................

 

11

 

E5–

 

cell

 

out

 

of

 

range

 

..........................................................................................................................

 

11

 

E6

 

 

cell

 

out

 

of

 

range

 

.........................................................................................................................

 

12

 

E7

 

 

heat

 

exchanger

 

error

 

.................................................................................................................

 

12

 

E8

 

 

inadequate

 

coolant

 

....................................................................................................................

 

12

 

5.

  

Turret

 

6

 

Specifications

 

......................................................................................................................

 

13

 

Appendix:

 

Serial

 

Communications

 

for

 

the

 

TC

 

1

 

Temperature

 

Controller

 

.............................................

 

14

 

 

 

 

Содержание Turret 6

Страница 1: ...19 8606 Tel 509 624 9290 Fax 509 624 9488 E mail quantum qnw com Web www qnw com Turret 6 6 Position Temperature Controlled Cuvette Turret for UV Vis Spectrophotometry Manual Product Overview 3 18 201...

Страница 2: ...g the MenU BUTTON 6 3 Features of the Turret 6 8 A GENERAL DESCRIPTION 8 B CUVETTE HOLDER 9 C CUVETTE Z HEIGHT 9 E COOLING WATER FOR THE PELTIER 10 F DRY GAS TO MINIMIZE CONDENSATION 11 G EXTERNAL TEM...

Страница 3: ...spectrophotometer 2 TC 1 Temperature Controller 3 power cable 4 USB cable 5 6 magnetic stir bars 6 vinyl tubing to connect water and gas B DEPENDING ON YOUR ORDER THE SHIPMENT MAY ALSO CONTAIN BATH 1...

Страница 4: ...to the back of the TC 1 Temperature Controller on the 15 pin connectors labeled Sample and reference 5 Plug the power cable into the back of the TC 1 Temperature Controller and into a wall socket The...

Страница 5: ...age push the left arrow once to get to the Set Position page Once there use the top and bottom arrows to choose a position e g position 5 Press the SET button The cuvette holder will move to position...

Страница 6: ...lowly When it has locked onto a new target temperature the green LED will remain lit A rapidly flashing red LED usually means a loose electrical cable or inadequate water flow for the Peltier unit Not...

Страница 7: ...own arrows and press SET The page will update to show the Current rate in min to be the same as the Ramp rate With ramping set turning on temperature control will generate a linear ramp to the target...

Страница 8: ...to six cuvettes The center of the tower is hollow permitting light to pass into the entrance hole through the tower through a cuvette and exit the opposite side from the entrance A plastic cover enclo...

Страница 9: ...be light tight CAUTION Accidently attaching a water line to the dry gas barb will severely damage the instrument Attach the lines with care B CUVETTE HOLDER The Turret 6 holds standard 10 x 10 mm cuve...

Страница 10: ...tap for brief use You will need a flow of 100 300 ml minute This flow should require a pressure of about 3 5 psi 0 2 0 3 bar Do not exceed an input water pressure of 25 psi 1 7 bar as damage may occu...

Страница 11: ...to temperature changes Also the fine coiled wires of the YSI 423 conduct very little ambient heat to the thermistor at the end Excellent Series 500 probes can be obtained with diameters less than a mm...

Страница 12: ...he temperature controller is not receiving a reasonable response from the sensor on the heat exchanger Either the sensor has failed or a cable is not making a good connection E8 inadequate coolant war...

Страница 13: ...10 C temperature precision 0 05 C cuvette size outside dimensions 12 5 x 12 5 mm minimum cuvette height 30 mm magnetic stirring speed 0 to 1700 rpm cuvette z height 8 5 or 15 mm specified when orderin...

Страница 14: ...be established through a USB connection between the computer and the controller In this case the controller includes electronics which convert the USB connection to a serial communications port Howeve...

Страница 15: ...stirrer speed F1 MS 300 The lowest stirrer speed is 300 rpm F1 SS S 1000 Set stirrer speed to 1000 rpm F1 SS S 0 Turn stirrer off and set the speed to zero F1 SS Turn stirrer on and set it to the most...

Страница 16: ...us F1 IS R The controller has been powered off and back on again 7 Current Sample Temperature F1 CT What is the current temperature of the holder F1 CT 22 84 The current temperature is 22 84 C F1 CT 3...

Страница 17: ...n F1 PA Start automatic reporting of probe temperature every temperature increment set by the command above F1 PT 30 5 The current probe temperature is 30 5 degrees F1 PA Stop automatic reporting of p...

Страница 18: ...l send a response of the form F1 TT as a notification of the end of the ramp This response can be blocked at any time by previously sending the command F1 TT see command class 5 11 Heat Exchanger Temp...

Страница 19: ...buttons and the display on the front When a computer program is in use the TC 1 will automatically send reports to the program whenever a manual change has been made The commands in this section are i...

Страница 20: ...20 R1 TT R Stop reporting manual changes for the reference target temperature R1 RR R Stop reporting manual changes for the reference ramp...

Отзывы: