3
7. Do you have power applied?
—
No – Go to step
—
Yes – Go to step
SMcli <
ctrl_IP1
> -c “Set tray [
trayID
] powerCanister[top|bottom] service
Allowed Indicator=on;”
—
[trayID]
is the identifier of the drive tray that contains the power canister that you want to replace. Drive tray ID
values are 0 to 99. Be sure to type the square brackets around the identifier.
—
[top|bottom]
is the identifier of the power canister that you want to replace. Power canister values are either
top or bottom. Be sure to type the square brackets around the value.
This command turns on the blue Power Service Action Allowed LED and prevents the controller from accessing the
drive tray (
ATTENTION Possible loss of power
– To avoid taking the wrong power canister offline and causing the drive tray to lose
all power, contact your Technical Support representative before performing step
8. Turn off the Power switch on the power canister that has failed (
).
Figure 3 Power Switch on the DE6600 Drive Tray
1.
Power Switch
9. Unplug the power cord from the failed power canister.
10. Remove the power canister from the drive tray (
) by pressing the orange tab toward the black tab, moving the
power canister latches to the outside, and then pulling the power canister toward you.
While removing the power canister, you might notice an increase in fan speed. The fan speed returns to normal after
you have replaced the power canister.
Figure 4 Removing and Replacing a Power Canister
1.
Power Canister Latches