Care and Maintenance

The Kozmo and Kozmo Portable are sophisticated power 
chairs. Like any motorized vehicle, it requires routine 
maintenance checks. You can perform some of these checks, 
but others require assistance from a Quantum Rehab 
Provider. Preventive maintenance is very important. If you 
follow the maintenance checks in this section as scheduled, 
you can help ensure that your power chair gives you years of 
trouble-free operation. If you have any doubt as to your power 
chair’s care or operation, contact a Quantum Rehab Provider.

Do not service the power chair when the seat is occupied.

Your power chair, like most electrical equipment, is susceptible 
to damage from the elements. Avoid damp areas of any kind.

Direct or prolonged exposure to water or dampness could 

cause the power chair to malfunction electronically and 

mechanically. Water can cause electrical components 

to corrode and the chair’s frame to rust. Power chairs 

should be examined periodically for signs of corrosion 

caused by water exposure, bodily fluid exposure, or 

incontinence. Damaged components should be replaced 

or treated immediately.

Should your power chair come in contact with water:
1.  Dry your power chair as thoroughly as possible with a 

towel.

2.  Allow your power chair to sit in a warm, dry place for 12 

hours to allow unseen water to evaporate.

3.  Check the controller operation and the brakes before 

using your power chair again.

4.  If any inconsistencies are found, take your power chair to a 

Quantum Rehab Provider. Power chairs that are frequently 
exposed to sources of water, such as incontinence, 
should be inspected often for corrosion and electronic 
components may need to be replaced frequently.

Temperature

 

„

Some of the parts of your power chair are susceptible 
to extreme changes in temperature. Always keep your 
power chair between the temperatures of 18°F (-8°C) 
and 122°F (50°C).

 

„

In extremely cold temperatures the batteries may freeze. 
The specific temperature at which they freeze depends 
on a number of factors, such as battery charge, usage, 
and composition of the batteries (e.g., AGM).

General Guidelines

 

„

Avoid knocking or bumping the controller.

 

„

Avoid prolonged exposure of your power chair to extreme 
conditions, such as heat, cold, or moisture.

 

„

Keep the controller clean.

 

„

Check all connectors to ensure that they are all tight and 
secured properly.

 

„

If your power chair is equipped, make sure pneumatic 
tires are inflated to the psi/bar/kPa air pressure rating 
indicated on each tire.

Make sure pneumatic tires are inflated to the psi/bar/

kPa air pressure rating indicated on each tire. Do not 

underinflate or overinflate your tires. Low pressure may 

result in loss of control, and overinflated tires may burst. 

Overinflating tires can cause them to explode.

Do not use a high pressure hose to inflate your tires.

 

„

Use a rubber conditioner on the tire sidewalls to help 
preserve them.

Never use a rubber conditioner on the tread areas of the 

tires; doing so may make the tires slippery and cause 

your power chair to skid.

 

„

All wheel bearings are prelubicated and sealed. They 
require no subsequent lubrication.

 

„

The body shroud has been sprayed with a clear sealant 
coating. You can apply a light coat of car wax to help it 
retain its high-gloss appearance.

 

„

If your power chair has a body shroud with a 

glossy finish

the body shroud has been sprayed with a clear sealant 
coating. You can apply a light coat of car wax to help it 
retain its high-gloss appearance. If your power chair has 
a body shroud with a 

matte finish, use ONLY products 

developed for matte-finish paint. Do not use wax, detail 
spray, ArmorAll®, or any product made for glossy paint.

Carefully choose the correct product to protect the 

finish of your power chair’s shroud(s). ONLY products 

developed for matte-finish paint should be used on 

shrouds with a matte finish. Failure to follow this warning 

may result in damage to the shroud’s matte paint finish.

 

„

Check all electrical connections. Make sure they are 
tight and are not corroded. Batteries must sit flat within 
the battery tray, with the battery terminals facing inward, 
toward each other. Refer to the battery wiring lable for 
the correct wiring layout.

Even though the power chair has passed the necessary 

testing requirements for ingress of liquids, you should 

keep electrical connections away from sources of 

dampness, including direct exposure to water or bodily 

fluids and incontinence. Check electrical components 

frequently for signs of corrosion and replace as necessary.

WARNING!

WARNING!

WARNING!

WARNING!

WARNING!

WARNING!

CARE AND MAINTENANCE

Содержание KOZMO

Страница 1: ......

Страница 2: ...INFMANU4938 Rev C April 2018 SECURITY GUIDELINES Intended Use The intended use of the Pride Mobility Products device is to provide mobility to persons limited to a seated position that have the capacity of operating a powered wheelchair Regarding Devices for Prescription Use CAUTION Federal law restricts this device to sale by or on the order of a physician or other certified personnel licensed by...

Страница 3: ...mon to the USA Since we recognize that not all English speaking countries use the same words or spellings please refer to the following chart for some common word variations that may be encountered throughout this manual asphalt tarmac authorized authorised backward s rearward s caster castor center centre color colour cord lead counterclockwise anticlockwise curb kerb elevator lift labor labour m...

Страница 4: ...4 KOZMO AND KOZMO PORTABLE Seat Assembly Power Base Assembly Back Canes Drive Wheel Caster Wheel Foot Platform Seat Pan Controller Joystick Armrest Manual Freewheel Lever Seat Base Seat Back Handle ...

Страница 5: ...onal assistance for setup or operation please contact your Quantum Rehab Provider Failure to follow the instructions in this manual and those located on your power chair can lead to personal injury and or damage to the power chair including voiding the warranty Purchaser s Agreement By accepting delivery of this product you promise that you will not change alter or modify this product or remove or...

Страница 6: ...ttendant can be defined as a family member or care professional specially trained in assisting a power chair user in various daily living activities As you begin using your power chair during daily activities you will probably encounter situations in which you will need some practice Simply take your time and you will soon be in full and confident control as you maneuver through doorways on and of...

Страница 7: ...e Batteries and Charging Main Circuit Breaker The main circuit breaker is a safety feature built into your power chair When the batteries and the motors are heavily strained e g from excessive loads the main circuit breaker trips to prevent damage to the motors and the electronics If the circuit trips allow your power chair to rest for approximately one minute Next push in the circuit breaker butt...

Страница 8: ...e motors drive mode 3 Pull the two levers toward the rear of the power chair to disengage the drive motors freewheel mode If a lever is difficult to move in either direction rock your power chair back and forth slightly The lever should then move to the desired position Do not use the freewheel lever handles as tie down points to secure this product Anti Tip Wheels The anti tip wheels are an integ...

Страница 9: ...rior to initial operation or after transporting your power chair The seat is attached to the power base by a height adjustable seat post Do not pick up the seat frame by the armrests They are free to pivot and you may lose control of the seat if they do so To install the seat 1 Adjust the seat height if necessary See Comfort Adjustments Set the seat onto the seat post See figure 3 2 Install the co...

Страница 10: ...er and swivel the seat back and forth while lifting up on the seat 6 Grasp the battery box handle and lift up to disengage the box from the power base then tilt the box foward slightly and pull it away from the power base 7 Disconnect two halves using the frame release lever Assembly of the Kozmo Portable 1 Use the frame release lever to lift the front section as you align the frame hooks of the f...

Страница 11: ...ustments metric standard socket set and ratchet adjustable wrench metric standard hex key set thread lock Seat Height Adjustment You can adjust the seat to two different heights in 1 in 2 5 cm increments Seat height adjustment requires the removal of the battery box To change the seat height 1 Turn off the power to the controller 2 Ensure the power chair is in drive mode See figure 2 3 Disconnect ...

Страница 12: ...stments 3 16 in hex key To change the controller position 1 Turn off the power to the controller 2 Unplug the controller connector from the power base 3 Remove any wire ties securing the controller harness to the armrest 4 Loosen the mounting screws in the controller mounting block See figure 10 5 Move the controller mounting block and controller to the other armrest tighten the mounting screws an...

Страница 13: ...ehicle should be properly belted into seats approved by the vehicle manufacturer The positioning belt should be secured at all times Never allow the positioning belt to hang or drag on the floor as it may become entangled To install the positioning belt 1 Remove the rearmost screw that holds the seat hinge to the seat base on both the left and right seat hinges 2 Insert the screw through the suppl...

Страница 14: ...upplied with the battery charger before charging the batteries WARNING Explosive gases may be generated while charging the batteries Keep the power chair and battery charger away from sources of ignition such as flames or sparks and provide adequate ventilation when charging the batteries PROHIBITED Never use an extension cord to plug in your battery charger Plug the charger directly into a proper...

Страница 15: ...et and then from the battery box 6 Reinstall the battery box to the power base Battery Break in To break in new batteries for maximum efficiency 1 Fully recharge any new battery prior to its initial use This brings the battery up to 90 of its peak performance level 2 Operate your power chair throughout the house and yard Move slowly at first and do not travel too far until you become accustomed to...

Страница 16: ...e the battery box grasp the battery box handle and lift up to disengage the box from the power base 2 Tilt the battery box forward slightly 3 Lift the battery box away from the power base 4 To install the battery box grasp the battery box handle and tilt the box forward slightly 5 Place the battery box on the power base 6 Push the back of the battery box down until it is firmly in place BATTERIES ...

Страница 17: ...ged as often as possible They do not have a memory like nickel cadmium batteries We work closely with our battery manufacturer to provide a battery that best suits your power chair s specific demands Fresh batteries arrive regularly at Quantum Rehab and are promptly shipped with a full charge During shipping the batteries encounter temperature extremes that may influence initial performance Heat r...

Страница 18: ...power chair to extreme conditions such as heat cold or moisture Keep the controller clean Check all connectors to ensure that they are all tight and secured properly If your power chair is equipped make sure pneumatic tires are inflated to the psi bar kPa air pressure rating indicated on each tire Make sure pneumatic tires are inflated to the psi bar kPa air pressure rating indicated on each tire ...

Страница 19: ...d changes in the function or performance of the power chair See your Quantum Rehab Provider for service and repair Keep your power chair clean and free of foreign material such as mud dirt hair food drink etc Yearly Checks Take your power chair to a Quantum Rehab Provider for yearly maintenance especially if you use your chair on a daily basis This helps ensure that your power chair is functioning...

Страница 20: ...changing the tire remove only the center lug nut and washer then remove the wheel If any further disassembly is required deflate the tire completely or it may explode To change the wheel 1 Turn off the power to the controller 2 Set the power chair up on blocks 3 Remove the drive wheel nut and washer from the axle See figure 15 4 Pull the wheel off the axle 5 Slide the new wheel back onto the shaft...

Страница 21: ...et and ratchet adjustable wrench screwdriver To replace the batteries 1 Remove the battery box from the power chair 2 Turn the pack upside down 3 Remove all screws that hold the battery box halves together See figure 17 4 Flip the battery box back over so the handle is up and remove the lid 5 Remove the red positive and black negative battery cables from each battery 6 Unfasten the hook and loop s...

Страница 22: ...ut does not move Loose seat or seating components Corrective Maintenance If the battery condition meter does not light up when you turn on the power Check the harness connections Make sure they are tight Check the circuit breaker Reset it if necessary Check the battery connections If the above conditions prove normal you can load test the batteries with a battery load tester These testers are avai...

Страница 23: ......

Страница 24: ... www pridemobility co nz UK 32 Wedgwood Road Bicester Oxfordshire OX26 4UL www quantumrehab co uk B V Authorised EU Representative De Zwaan 3 1601 MS Enkhuizen The Netherlands www quantumrehab eu Italy Via del Progresso ang Via del Lavoro Loc Prato della Corte 00065 Fiano Romano RM www quantumrehab italia it France 26 rue Monseigneur Ancel 69 800 Saint Priest www quantumrehab fr Spain Calle Velazq...

Отзывы: