System Status Light

The system status light is normally on when the system is powered up, and off when the system is 
powered down. This light will flash if there is an internal fault, or if an OONAPU fault has occurred. See 
“Out Of Neutral At Power Up.”

Magnetic Locking Area

Your power chair is equipped with a feature that enables you to “lock out” unauthorized users. For this 
function, you will need the magnetic key supplied with your power chair. If you lose this key, contact your 
Pride/Quantum Provider.

To enable the lockout system:

1.  Hold the magnetic key on or near the key symbol. The system will beep and automatically turn off.

NOTE: None of the remote lights should be lit.

2.  Press the on/off key to turn on the power chair. The key symbol will flash, but you will not be able to 

drive your power chair. This means that it is still locked.

3.  Hold the magnetic key on or near the key symbol again to unlock the system. When the key symbol 

stops flashing, you may turn on the power chair.

NOTE: If you turn on the power chair while it is locked and do not unlock it after one minute, the 

power chair will automatically turn off itself.

Battery Condition Meter

The battery condition meter consists of six lights arranged in an arc over the battery icon. From left to 
right, the first two are red, the second two are orange, and the last two are green. These lights give 
you an accurate indication of your usable battery capacity. If the battery has at least 85% of its rated 
capacity, all of the lights will be on. As the battery voltage drops, the number of lights reduces from right 
to left. When the battery capacity drops to 10% or below, all of the lights will flash once every second.

NOTE: When the battery capacity drops to below 21V (typically two lights), the controller will 

reduce power chair performance to conserve battery power.

Drive Program Select Key

The drive program select key enables you to select a drive program and a power accessory mode. Your 
Europa Controller was preprogrammed for five drive programs—1 (slowest) to 5 (fastest). The drive 
mode is indicated by a number in the center of the keypad (drive mode and actuator display).

NOTE: The drive mode settings are preset at the factory. If your Pride/Quantum Provider changes 

these settings, please make note of these changes.

To change the drive program:

1.  Press the drive program select key until your desired drive program is displayed.
2.  Use the joystick to operate your power chair.

Содержание Europa

Страница 1: ...Basic Operation Instructions I O Europa Controller...

Страница 2: ...icon is represented as a white symbol on a blue dot with a white border PROHIBITED These actions are prohibited These actions should not be performed at any time or in any circumstances Performing a...

Страница 3: ...troller 6 Operating the Europa Controller 10 Controller Communications Connector 13 Off Board Charger Socket 13 Power Accessory Control 13 Battery Saver Feature 14 Sleep Mode 14 Out of Neutral at Powe...

Страница 4: ...portant for you to read them and understand them completely Read and follow the information in the owner s manual Avoid exposure to rain snow ice salt or standing water whenever possible Maintain and...

Страница 5: ...on to the power base owner s manual that came with your power chair If there is any information in this manual which you do not understand or if you require additional assistance for setup or operatio...

Страница 6: ...lity and braking If it is programmed incorrectly or outside of the safe limits as determined by your healthcare professional it can create a dangerous situation Only the power chair manufacturer an au...

Страница 7: ...ll phones two way radios laptops electricity generators or high power sources and other types of radio transmitters may cause unintended movement of your electrically powered mobility vehicle due to E...

Страница 8: ...l The joystick is used to control the direction and speed of the power chair Actuator Adjustment The user can control positioning of power seat actuators with the Europa Drive Profile Selection The us...

Страница 9: ...Magnetic Key Lock System is not in use System Status Light Indicates the On Off status of the power chair and flashes to indicate system faults Magnetic Key Lock System LED Magnetic key used to power...

Страница 10: ...allow it to return to the neutral position you engage the electromagnetic brakes This causes your power chair to decelerate and come to a complete stop Keypad The keypad is located directly in front o...

Страница 11: ...11 1 0 1 2 3 4 Figure 2 Europa Controller Figure 3 Europa Keypad...

Страница 12: ...rn off itself Battery Condition Meter The battery condition meter consists of six lights arranged in an arc over the battery icon From left to right the first two are red the second two are orange and...

Страница 13: ...essory actuators are selected and controlled using the joystick To select a power accessory actuator 1 Press the drive program select key until the 7 segment display displays A NOTE The power chair wi...

Страница 14: ...eter lights are flashing you may have set an error code See Error Codes Error Codes The system status light is displayed within the on off key This light is lit if the system is turned on It also flas...

Страница 15: ...otor brake itself is shorted Check motor brake wiring 6 Right Park Brake or connection Fault The connection between the power module and the right motor brake is either open or shorted or the motor br...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ......

Страница 20: ...ire OX26 4UL www quantumrehab co uk Australia 20 24 Apollo Drive Hallam Victoria 3803 www quantumrehab com au New Zealand 38 Lansford Crescent Avondale Auckland New Zealand 1007 www pridemobility co n...

Отзывы: