![Quantum DLT 2500 Скачать руководство пользователя страница 271](http://html1.mh-extra.com/html/quantum/dlt-2500/dlt-2500_product-manual_3624549271.webp)
DLT2000 SCSI Interface
DLT2000/DLT2700 Cartridge Tape Subsystem 8-125
Fixed
The fixed bit specifies both the meaning of the Transfer Length field and whether fixed-
length or variable-length blocks are to be transferred. If the Fixed bit is set to zero,
Variable Block mode is selected. A single block is transferred from the initiator and is
written to the logical unit beginning at the current logical tape position. Upon successful
termination, the tape is logically positioned after this block (EOM/P side). The Transfer
Length specifies the number of bytes that the drive handshakes out from the initiator.
If the Fixed bit is set to one, the Transfer Length field specifies the number of blocks to
be transferred to the host beginning at the current tape position. This form of WRITE is
valid only if the logical unit is currently operating in Fixed Block mode, in other words,
when it has been instructed to use fixed-length blocks with MODE SELECT. The
current block length is the block length defined in the MODE SELECT command.
Upon termination, the tape is logically positioned after these blocks.
Transfer Length
This field contains the length of the data transfer in bytes or blocks, depending on
whether Fixed or Variable block mode is selected.
If the Transfer Length is zero, no data is transferred and the current position on the
logical unit is not changed.
Exception Conditions
If EOT is detected while writing, the drive will finish writing any buffered data. The
command terminates with CHECK CONDITION status. Within the Sense data, the
EOM bit is set, the Sense Key field is set to NO SENSE, and the Additional Sense
Code and Additional Sense Code Qualifier fields are set to EOM/P detected. The drive
attempts to complete any subsequent writes, returning a CHECK CONDITION status in
each case.
If the drive encounters the physical EOM when attempting write, CHECK
CONDITION status is returned. Within the Sense data, the EOM and Valid bits are set,
and the Sense Key field is set to Volume Overflow The Information fields contain the
residue count and the Additional Sense Code and Additional Sense Code Qualifier
fields are set to EOM/P Detected. The tape is physically positioned at EOM/P.
Содержание DLT 2500
Страница 18: ...Table of Contents xviii DLT2000 DLT2500 DLT2700 Cartridge Tape Subsystem ...
Страница 20: ...Revision History xx DLT2000 DLT2500 DLT2700 Cartridge Tape Subsystem ...
Страница 38: ...Installing and Configuring the DLT2000 Tabletop Drive 2 12 DLT2000 DLT2500 DLT2700 Cartridge Tape Subsystem ...
Страница 94: ...Configuring and Operating the DLT2500 Mini Library 4 30 DLT2000 DLT2500 DLT2700 Cartridge Tape Subsytem ...
Страница 120: ...Configuring and Operating the DLT2700 Mini Library 5 26 DLT2000 DLT2500 DLT2700 Cartridge Tape Subsystem ...
Страница 146: ...Firmware Update From Tape 7 18 DLT2000 DLT2500 DLT2700 Cartridge Tape Subsystem ...
Страница 291: ...DLT2000 SCSI Interface DLT2000 DLT2700 Cartridge Tape Subsystem 8 145 ...
Страница 321: ...Definition of Vendor Unique Sense Data Information B 4 DLT2000 DLT2500 DLT2700 Cartridge Tape Subsystem ...
Страница 327: ...Sense Key Information C 6 DLT2000 DLT2500 DLT2700 Cartridge Tape Subsystem ...