Owner’s Manual
Quantum Energy Technologies
Document number: QDC0030PD-11 Page 36 of 40
A.11: Technical Data For Service Personnel – SIAM Compressors – R134a
Parameters
150-08ACW-134
270 & 340-11AC3-134
340TIH-134
340-17ACW-134
Superheat setting
1.5Turn(F.Close)
3.5 Turns(7 Turns ) F..Open
3.5Turns(7Turns) F.Open
TX valve + orifice size
TI-E 2#
TEN2 # 3(AAE 2MC)
TEN2 # 4
Winding Resistance @20
℃
C-R:
2.13
Ω
, C-S: 3.91
Ω
C-R:
0.96
Ω
, C-S: 1.77
Ω
Run Capacitor
30
μ
F (+10, -5%) 370 VAC
30
μ
F (+10, -5%) 370 VAC
60
μ
F (+0, -15%) 400 VAC
Rated power supply
220-240VAC, 50Hz
220-240VAC, 50Hz
220-240VAC, 50Hz
Rated circuit breaker
1
Φ
, 15A
1
Φ
, 15A
1
Φ
, 15A
De-ice control setting
On-5
℃
, Off + 8
℃
(Timed De Icing) On - 5
℃
, Off + 8
℃
(Timed De Icing) On-5
℃
, Off + 8
℃
(Timed De Icing)
Liquid injection capillary
Eyre: ID 1.1mm x 1.5m
Eyre: ID 1.1mm x 2.9m
ID 1.1mm x 2m
Liquid injection thermostat
On at 85
℃
, Off at 75
℃
On at 85
℃
, Off at 75
℃
On at 85
℃
, Off at 75
℃
Water temperature setting
55
℃
/5
℃
(Del.
≥
60
℃
) 55
℃
/5
℃
(Del.
≥
60
℃
)
55
℃
/5
℃
(Del.
≥
60
℃
)
Refrigerant charge
1650g
1850g
2650g
Thermal cut-out setting
105
℃
, manual reset
105
℃
, manual reset
105
℃
, manual reset