6f.2: Five Year Service (By Authorized Personnel Only)
The five-year service should be carried out by a licensed tradesperson every five years. It is
recommended that your local Quantum distributor carry out this service. The service should
include the following: -
1. Replace the Pressure & Temperature Relief valve.
2. Replace the anode.
3. Flush the water heater.
4. Checking of the refrigeration system.
5. Checking of thermostats, digital controller and electrical components.
If in doubt, contact Quantum Energy Technologies for your nearest distributor or service
contractor. Our website
www.quantumenergy.com.au
also provides an up to date list of Quantum
distributors.
6f.3: Access & Removal Of Sacrificial Anode
The anode can be accessed via the heat pump section, to remove.
1. Turn off power to the unit.
2. Remove the screws around the top cover of the heat pump & remove the heat pump top
cover.
3. For easier access the front inspection panel on the heat pump section should also be
removed.
4. Locate and remove the plastic plug through the centre of the heat pump chassis.
5. The anode head is now accessible and can be unscrewed with a suitable 1
1
/
16
” socket
wrench.
6. Once unscrewed the anode can be drawn out through the top of the tank / heat pump
section.
7. The new anode can then be fitted and the heater reassembled.