Sensors & Transducers Journal, Vol.76, Issue 2, February 2007, pp.935-936
[23]. Sean Brahim, Amperometric determination of cholesterol in serum using a cholesterol oxidase biosensor
with a polypyrrole / hydrogel membrane. Anal. Chim. Acta. 448 (2001), pp. 27-36.
[24]. R Koncki, Urea determination using pH-enzyme electrode. J. Pharma. Biomed. Anal. 21 (1999), pp. 51-57.
[25]. Fenfen Zhang, Xiaoli Wang, Shiyun Ai, Zhengdong Sun, Qiao Wan, Ziqiang Zhu, Yuezhong Xian, Litong
Jin, and Katsunobu Yamamoto, Immobilization of uricase on ZnO nanorods for a reagentless uric acid
biosensor Analytica Chimica Acta 519 (2004) 155–160.
[26]. F. Hong, N. O. Nilverbrant, and L. J. Jonsson, Rapid and convenient determination of oxalic acid
employing a novel oxalate biosensor based on oxalate oxidase and SIRE technology. Biosens. Bioelectron.,
18 (2003), pp.1173-1181.
[27].
Ravi Kumar Reddy, Anju Chandre, and Enakshi Bhattaharya, Porous silicon based potentiometric
triglycerides biosensors. Biosens. Bioelectron., 16 (2001), pp. 313-317.
[28]. E. T.
Marques
, and J.
Lima Filho
, Ascorbic acid biosensor using ascorbate oxidase immobilized on
alkylamine glass beads. Appl. Biochem. Biotechnol., (1992), 32 : 73.
[29].
C. S. Rui, H. I.-Ogawa, K. Sonomoto and Y. Kato,
A multifunctional flow-injection biosensor for the
simultaneous determination of ammonia, creatinine, and urea, Ann. NY Acad. Sc., 750(1995), pp. 30-38.
[30]. K A Erickson, and P Wilding, Evaluation of a novel point-of –care system, the i- STAT portable clinical
analyzer. Clin chem. 39(1993), pp. 287-293.
[31].Philips demonstrates magnetic biosensor for high-sensitive molecular diagnostics, Press release,
9 December, 2004.
[32]. K. Bruce Jacobson, Biosensors and other medical and environmental probes.
http://www.ornl.gov/info/ornlreview/rev29_3/text/biosens.htm
[33].G. H. Keller, and M. M. Manall, DNA Probes. Macmillan: New York, 1989, 1-23.
[34].Jaiswal Jyoti, K. et. al., Long-term multiple colour imaging of live cells using quantum dot bioconjugates.
Nature. Biotechnol., 2003, 21, 47-51.
[35].W. C. Chan, and S. Nie, Quantum dot bioconjugates for ultrasenstive nonisotopic detection. Science, 281
(1998), pp. 2008-2016.
[36]. M. Minunni, S. Tombelli, R. Seielzi, I. Mnelli, C. Mascini Mand Gaodiano, Detection of
β
-thalassemia by
a DNA piezoelectric biosensor coupled with polymerase chain reaction. Anal. Chim. Acta. 481(2003), pp.
55-64.
[37]. K. M. Millan, Saraullos and S. R. Mikkelssen, Valtammetric DNA biosensor for cystic fibrosis based on a
modified carbon paste electrode. Anal. Chem. 66(1994), pp. 2943-2948.
[38]. P. A. E. Piunno, U. J. Krull, R. H. E. Hudson, M. J. Damha and H. Cohen, Fiber optics biosensor for
fluorimetric detection of DNA hybridization. Anal. Chim. Acta. 288(1994), pp. 205-214.
[39]. S. O. Kelly, E. M. Boon, J. K. Barton, N. M. Jackson and M. G. Hill, Single-base mismatch detection based
on charge transduction through DNA. Nucleic Acid Res. 27(1999), pp. 4830-4837.
[40]. S. Sawata, E. Kai, K. Ikebukuro, T. Lida, T. Honda and I. Karube, Application of peptide nucleic acid to
the direct detection of deoxyribonucleic acid amplified by polymerase chain reaction. Biosensor.
Bioelectron. 14(1999), pp.397-404.
[41].Shana O. Kelley and Jacqueline K. Barton, Electron Transfer between Bases in Double Helical DNA.
Science. 283(1999), pp. 375-381.
[42]. D. B.
Hall
, J. K.
Barton
, Sensitivity of DNA-Mediated Electron Transfer to the Intervening
π
-stack: A
Probe for the Integrity of the DNA Base Stack. J. Am. Chem. Soc., 1997, 119, 5045-5046.
[43].Motorola Life Sciences Inc. (
http://www.motorola.com/lifesciences/
)
[44].
Suzanne D. Vernon , Daniel H. Farkas, Elizabeth R. Unger , Vivian Chan , Donna L. Miller , Yin-
Peng Chen , Gary F. Blackburn and William C. Reeves,
Bioelectronic DNA detection of human
papilloma viruses using eSensorTM: a model system for detection of multiple pathogens. BMC Infect. Dis.,
2003, 3:12.
[45].Toshiba Corporation, (http://dna-chip.toshiba.co.jp/eng/)
[46]. A. Erdem, K. Kerman, B. Meric, U. S. Akarea, M. Osoz. Novel hybridization indicator mythylene blue for
the electrochemical detection of short DNA sequence related to Hapitis B virus, Anal. Chim. Acta.
422(2000), pp. 139-149.
_____________________
2007 Copyright ©, International Frequency Sensor Association (IFSA). All rights reserved.
(http://www.sensorsportal.com)
944