![Quantum Harvest 5000-60 TSW Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/quantum-harvest/5000-60-tsw/5000-60-tsw_owners-manual_770882022.webp)
Battery numbering schematic
Battery #1 Battery #2 Battery #3
Control panel
end.
Control panel
removed for
clarity.
Battery #4 Battery #5 Battery #6 Battery #7 Battery #8
NOTE: The battery cables are all labeled with either white or yellow labels. Please note
that the 4 white-labeled cables, A, B, C, D are black, and are the only ones that go to both
red (positive), and black (negative) battery terminals. The yellow-labeled cables are either
red, which connect only to red (positive) terminals, or black, which connect only to black
(negative) battery terminals.
Step 4
:
Above;
Remove the nut, flat washer and lock washer from only one battery terminal at
a time, and it is recommended to place a piece of clear plastic hose or other insulator over each
cable end as it is freed. This prevents the possibility of a freed end touching an adjacent
terminal, causing a very dramatic short circuit, likely damaging both the terminal and the cable
end! Remove the cables in reverse letter order, ie: start with the large red cable marked “L”,
then the large black cable marked “K” and so forth until all the cables are removed. The
batteries may now be removed from the case. Each battery weighs 70 lbs, so some help may be
appreciated!
Be very careful that freed ends as well as any tools do not
short across adjacent terminals!
20
Содержание 5000-60 TSW
Страница 2: ......
Страница 9: ...7 ...
Страница 25: ...Cable A Cable B Cable C Cable E Cable D Cable F 23 ...
Страница 26: ...Cable G Cable H Cable I 24 ...