QE7020
INSTALLATION INSTRUCTIONS
ALL ELECTRICAL WORK SHOULD BE CARRIED OUT BY A COMPETENT ELECTRICIAN
1 Decide on a suitable location.
2 Mark the positions of the holes for the two mounting screws. (supplied)
3 Fix the screws leaving 15mm protruding from the wall.
4 Mark the position for the 13A Fused Spur connection.
5 Install the fused spur back box and supply cable. (Surface mount or sunken)
6 Mount the heater on to the two screws.
7 Ensure that the mains supply is turned off.
8 Connect the supply to the fused spur front plate.
9 Connect the unit to the front plate as described below.
10 Replace the front plate.
11 Installation is now complete.
CONNECTION DETAILS
THIS UNIT MUST BE CONNECTED TO THE MAINS SUPPLY BY A SWITCHED SPUR
The wires in the cable attached to this unit are coloured in accordance with the following code:-
BROWN
======================
LIVE
BLUE
====================
NEUTRAL
THIS UNIT DOES NOT REQUIRE AN EARTH WIRE AS THE CASE IS DOUBLE INSULATED
As the colours may not correspond with the markings indentifying the terminals in the fused spur proceed
as follows.
•
Blue wire must be connected to the terminal marked ‘N LOAD’
•
Brown wire must be connected to the terminal marked ‘L LOAD’