780B Video Generator/Analyzer
– User Guide
Page 199
December 1, 2014
Revision A7
Table 11-1: List of Commands (alphabetical)
– For Testing HDMI Sink Devices
Command
Description
Syntax
Parameters
Command Example
HSPG
Sets enable gate of
the horizontal sync
pulse.
HSPG <
enable
>
HSPG?
< enable >
Where
enable
is:
0 = disable
1 = enable
To enable the horizontal sync
pulse:
HSPG 1
ALLU or FMTU
IMGL
Loads an image
(pattern).
IMGL <
image
>
Where
image
is one of the
images listed in Table 7-4
See example below for IMGU
IMGU
Activates an image
that has been loaded
and queries for the
currently active image.
IMGU
IMGU?
Not applicable
To load and invoke a image
load command:
IMGL SMPTEbar
IMGU
NBPC
Sets or queries the
number of bits per
component. Applies
only to HDMI
NBPC <
bit_depth
>
NBPC?
Where
bit_depth
is one of:
8 – 8 bits per component
10 – 10 bit per component
12 – 12 bits per component
To set the HDMI bit depth to
10:
NBPC 10
ALLU or FMTU
PRAT?
Queries the pixel rate
of the outgoing HDMI
format.
PRAT?
Not Applicable
To read the pixel rate of the
outgoing HDMI signal:
PRAT?
+74.2500E+06
RGBW
Sets RGB values on
with Raster and
Window test patterns
RGBW
<pattern> <R>
<G> <B>
RGBW?
<pattern> <R> <G>
<B>
Where pattern is either 4 for
Window pattern or 33 for
raster pattern.
Where
R G B
are the
respective values for the
RGB color components
To set the Window pattern to
dark brown:
imgl window
imgu
rgbw 4 115 82 68
or
rgbw 4 115 87 74
SCAN
Defines whether the
active timing is
progressive or
interlaced or queries
the state of the active
timing.
SCAN <
scan
>
SCAN?
< scan >
Where
scan
is:
1 = progressive
2 = interlaced
To set the scan to interlaced:
SCAN 2
ALLU or FMTU
SIRE
Sets IRE levels for
certain images:
Window1/2, Raster,
Flat_Wht/Grn/
Red/Blu/Cyn/Mag/Blk
SIRE
<range>
Where
range
is a value from
0 to 100.
To set the IRE range for any of
the images listed:
SIRE 50
ALLU
SSST
Sets or queries the
sync type. Applies only
to analog outputs.
SSST <
sync_type
>
SSST?
Where
format_ty
pe is one of:
1 – separate sync
3 – sync on green
To set the analog sync type to
separate sync:
SSST 1
ALLU
VRES
Sets or queries the
vertical resolution of
the active timing.
Express in number of
lines.
VRES <
lines
>
VRES?
< lines >
Where
lines
can be within
the range of:
Min = 1 (if scan = 1)
= 2 (if scan = 2)
Max = VTOT – 1 (if scan = 1)
= VTOT – 3 (if scan =
2)
To set the horizontal resolution:
VRES 480
ALLU
Содержание 780B
Страница 1: ...780B Video Generator Analyzer User Guide Rev A7...
Страница 72: ...780B Video Generator Analyzer User Guide Page 71 December 1 2014 Revision A7...
Страница 106: ...780B Video Generator Analyzer User Guide Page 105 December 1 2014 Revision A7...
Страница 126: ...780B Video Generator Analyzer User Guide Page 125 December 1 2014 Revision A7...
Страница 183: ...780B Video Generator Analyzer User Guide Page 182 December 1 2014 Revision A7...
Страница 191: ...780B Video Generator Analyzer User Guide Page 190 December 1 2014 Revision A7...
Страница 224: ...780B Video Generator Analyzer User Guide Page 223 December 1 2014 Revision A7 END OF USER GUIDE...