Product Information

 

The Model 9730 Series is designed for airbag and 

pyrotechnic initiator testing and represents the latest in 

current pulse generating capabilities with compelling 

features that provide users with time-saving characteristics 

of adjustability, simple operation and programmability. The 

9730 comes in a 19” 2U form factor as a 2 or 4 channel 

model with current sensing and resistance measurement 

capabilities. This unit is ideal for applications that require a 

high level of accuracy and repeatability.

 

High functionality, safety, and a rapid 

return-on-investment are the hallmarks of this new fireset 

for pyrotechnic initiators. The Model 9730 provides 

multiple firing channels: all-fire, no-fire, resistance 

measurement, DC current, capacitor discharge, Bruceton, 

Neyer, and high current.The performance and advanced 

features of the 9730 current pulse generator make it ideal 

for applications such as air bag deployment testing (squib 

detonation) or igniter deployment that can be done 

reliably, safely and with repeatability.

Standard Features

• Up to 4 individual outputs with fully individual programming

and control.

• Up to 6A output per channel.
• Front and rear external trigger inputs.
• Current monitor –  The current output from the unit is monitored and a              

  voltage representation the waveform is presented at a front panel BNC  

  connector.

• Voltage monitor- The voltage across the load being driven is monitored      

  and a voltage representation is present at a front panel BNC connector. 
*Instantaneous power and total energy may be derived with the aid of   

  both the current and voltage monitors.

• SAFETY - Keyed front panel fire enable, mechanical and software

  interlocks.

• Complete channel and system setup stored in memory. Provides

12 memory storage slots.

• Meets Bruceton and Neyer requirements
• Analog signals depicting current and voltage

 

 

 

 

Advanced Features/Options

• Integrated 4-wire resistance measurement for each channel with pre and post testing features. Ability to set the mean and  

   upper/lower limits to determine what construes a resistance fault
• Current and voltage monitor outputs.
• Front and rear sync outputs.
• Safety features include remote interlock, removable keyed enable switch and internal error checking.
• RS232, USB, and optional Ethernet computer programming interfaces 

Содержание 9730 Series

Страница 1: ...uracy and repeatability Advanced safety features provide user assurance Basic Specifications 200 ns Timing Resolution 2 or 4 Channel Outputs 6 Amps Per Channel Easy Programming Interface Integrated Bridgewire Resistance Measurement Safety Interlocks and Keyed Front Panel Interface Quantum Composers Inc P O Box 4248 Bozeman MT 59772 Phone 406 582 0227 Fax 406 582 0237 Toll Free 800 510 6530 www Qua...

Страница 2: ... be done reliably safely and with repeatability Standard Features Up to 4 individual outputs with fully individual programming and control Up to 6A output per channel Front and rear external trigger inputs Current monitor The current output from the unit is monitored and a voltage representation the waveform is presented at a front panel BNC connector Voltage monitor The voltage across the load be...

Страница 3: ...ble 6 A varies with load rising edge resistive 550 ns 1 ohm 2 cable 6 A varies with load SLEW RATES rising edge inductive 2 A us 6 A varies with load 1 A us 3 A 0 30 A us 1 A 1 ohm and 50 cable falling edge inductive 1 60 A us 6 A varies with load 0 90 A us 3 A 0 30 A us 1 A 1 ohm and 50 cable rising edge resistive 6 3 A us 6 A varies with load 9 5 A us 3 A 2 2 A us 1 A 1 ohm 2 cable falling edge ...

Страница 4: ...al bridge RS232 115200 57600 38400 19200 9600 4800 baud size 9 2 U x 10 2U size rack mount electrical 100 240 V 50 60 Hz SAFETY remote interlock shorting interlock arming key switch removable keyswitch internal error checking checks control circuit for errors OPTIONS E ethernet amplitude 0 10 6 A SPECIFICATIONS 9730 Series accuracy 0 5 2 pulse width range 5 us 100 s resolution 100 ns error 0 1 vol...

Отзывы: