Communications Protocol
CubiScan 125 Command Set
CubiScan 125
101
Zero
This command should be issued periodically to force the CubiScan
125 to perform internal compensations to adjust to changes in tem-
perature and humidity. This command should only be issued when
the measuring field is free of packages! Never issue this command
when a package is present in the measuring field.
Pos
Len
Description
Type
Range
ASCII
Command Format
1
1
Start of Text
Control
(STX)
02h
2
1
Zero Command
Alpha
(Z)
5Ah
3
1
End of Text
Control
(ETX)
03h
4
1
Carriage Return
Control
(CR)
0Dh
5
1
Line Feed
Control
(LF)
0Ah
Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Zero Command
Alpha
(Z)
5Ah
3
1
Acknowledge
Alpha
(A)
41h
4
1
End of Text
Control
(ETX)
03h
5
1
Carriage Return
Control
(CR)
0Dh
6
1
Line Feed
Control
(LF)
0Ah
Negative Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Zero Command
Alpha
(Z)
5Ah
3
1
Neg. Acknowledge
Alpha
(N)
4Eh
4
1
End of Text
Control
(ETX)
03h
5
1
Carriage Return
Control
(CR)
0Dh
6
1
Line Feed
Control
(LF)
0Ah
Содержание CubiScan 125
Страница 8: ...Table of Contents iv CubiScan 125 Notes...
Страница 20: ...Assembling the CubiScan 125 Setup 10 CubiScan 125 Figure 4 CubiScan 125 Base Assembly on Optional Cart...
Страница 39: ...Setup Connecting to a Computer or Network CubiScan 125 29 13 Click the Hardware tab...
Страница 44: ...Setup Checklist Setup 34 CubiScan 125 Notes...
Страница 90: ...Computer Error Messages Troubleshooting 80 CubiScan 125 Notes...
Страница 124: ...Parts List 114 CubiScan 125 Notes...