- 9 -
To change the switching sensitivity, 1st press the “
SET
” button to go to the main screen.
Then press the “
DAY
” and “
COPY
” buttons one after the other. Following this, select
the desired switching sensitivity using the large
and
buttons. The notices
“ ”, “
” and “
” indicate ±0.1 °C, ±0.2 °C and ±0.3 °C, respectively. Finally, confirm
the setting by pressing the “
SET
” button (if no buttons are pressed for at least 15 seconds,
the setting is automatically confirmed). After this confirmation, the device goes back to the
main screen. You can read more about switching sensitivity in Section
3
.
2.5 Activation of the pump protection function
According to the factory default settings, the pump protection function is inactive. In order
to activate or deactivate it, 1st press the “
SET
” button to go to the main screen. Then press
the “
DAY
” and “
PROG
” buttons one after the other. Following this, activate or deactivate
this function by using the large
and
buttons. The notices “
” and
“
” indicate activated and deactivated state, respectively.
Finally, confirm the setting by pressing the “
SET
” button (if no buttons are pressed for
at least 15 seconds, the setting is automatically confirmed). After this confirmation, the
device goes back to the main screen.
To prevent the pump from sticking, the activated pump protection function switches on the
connected device for one minute period at 12:00 p.m. every day, if no switching has taken
place on the given day or the previous day (e.g. during the heating-free period).