- 20 -
condensation occurs which can cause serious damages. Using this function,
you can set the humidity level above which the thermostat will stop cooling to
prevent condensation.
7.7. Switching on and off of the pump protecting function (PUMP)
In order to prevent the pump from jamming, the activated pump protection
function will start the devices connected thereto for 1 minute every day at 12:00
p.m. (noon), if switching was not done either on the respective day or on the
previous day (e.g. during non-heating period). The pump protectionfunction
only works when the controlled device is in operable condition.
7.8. Restoring factory default setting (RESET)
This function resets all settings of the thermostat to factory default. To
restore factory default setting choose option “
RES
” at “
RESET
” function in
the setting menu and move on with the
button.
Leaving the “
RESET
” function in default state ( ) after touching the
button the thermostat saves the settings, exits this menu, and after returning
to the home screen continues its operation according to the operating mode
set beforehand.