I
NSTALLING
H
ARDWARE
I
NSTALLING
THE
E
XPANDER
B
ACKPLANE
2-50
3. Slide the expander BP toward the front of the chassis until
the B2B connectors (a, b & c) are connected to the HDD
BP.
4. Secure the HDD expander board to the chassis with four
(4) screws.
Figure 2-75. Installing the Expander Backplane Screws
5. Connect the following cables to the expander BP:
a. Golden finger for LED signals to HDD BP B2B connec-
tor.
b. Golden finger for LED signals to HDD BP B2B connec-
tor.
c. Golden finger for LED signals to HDD BP B2B connec-
tor.
d. 10 pin Power connector for BP with +12V, +5V,
+3.3V,GND
e. LSI SAS2x20 SAS 6G Expander IC.
f. SAS_1, Mini-SAS connector to Host Port 1 channel 4
~ 7.
g. SAS_0, Mini-SAS connector to Host Port 0 channel 0
~ 3.
h. System FAN 5 for CPU 1 Block
i. System FAN 4 for CPU 1 Block
j. System FAN 3 for CPU 1 Block
k. System FAN 2 for CPU 0 Block
l. System FAN 1 for CPU 0 Block
m. System FAN 0 for CPU 0 Block
n. Jumper setting of Expander operation mode
o. IPMB connector linking to on board BMC controller
FAN Speed
p. Winbond W83793 for FAN control
Содержание STRATOS S210 Series S210-X12RS
Страница 21: ...REVISION HISTORY XXI ...
Страница 22: ...About the Server Chapter 1 About the Server Chapter 1 ...
Страница 38: ...Installing Hardware Chapter 2 Installing Hardware Chapter 2 ...
Страница 104: ...BIOS Chapter 3 BIOS Chapter 3 ...
Страница 173: ...BMC Chapter 4 BMC Chapter 4 ...
Страница 240: ...Jumpers and Connectors Chapter 5 ...
Страница 245: ...Rail Kit Assembly Chapter 6 Rail Kit Assembly Chapter 6 ...
Страница 249: ...Troubleshooting Chapter 7 Troubleshooting Chapter 7 ...
Страница 254: ...Installation and Assembly Safety Instructions Chapter 8 Installation and Assembly Safety Instructions Chapter 8 ...
Страница 259: ...Safety Information Chapter 9 Safety Information Chapter 9 ...
Страница 267: ...Regulatory and Compliance Information Chapter 10 Regulatory and Compliance Information Chapter 10 ...