BMC
FRU I
NFORMATION
4-16
screenshot of Sensor Readings page is shown in the following
image:
Sensor Readings Page
A brief description of the Sensor Readings page fields is given
in the following sections.
Sensor Type
You can select a specific type of sensor from a drop-down
menu. The list of sensors include the Sensor Name, Status, and
Current Reading. The All Sensors option allows to view all the
available sensor details, and select a specific type of sensor.
When a specific type of sensor is selected, on the right hand
side of the screen will be displayed the Thresholds for the sen-
sor.
The total of six thresholds are available as follows:
Lower Non-Recoverable (LNR)
Lower Critical (LC)
Lower Non-Critical (LNC)
Upper Non-Recoverable (UNR)
Upper Critical (UC)
Upper Non-Critical (UNC)
The threshold states can be Lower Non-critical - going low,
Lower Non-critical - going high, Lower Critical - going low,
Lower Critical - going high, Lower Non-recoverable - going low,
Lower Non-recoverable - going high, Upper Non-critical - going
low, Upper Non-critical - going high, Upper Critical - going low,
Upper Critical - going high, Upper Non-recoverable - going low,
Upper Non-recoverable - going high.
Live Widget
The widget window can be turned On and Off for a selected
sensor. Widget provides a dynamic representation of the read-
Содержание STRATOS S400-X44E
Страница 24: ...About the Server Chapter 1...
Страница 36: ...Installing Hardware Chapter 2...
Страница 86: ...BIOS Chapter 3...
Страница 155: ...BMC Chapter 4...
Страница 217: ...Connectors and Jumpers Chapter 5...
Страница 221: ...Rail Kit Assembly Chapter 6...
Страница 227: ...Troubleshooting Chapter 7...
Страница 232: ...Installation and Assembly Safety Instructions Chapter 8...
Страница 237: ...Safety Information Chapter 9...
Страница 246: ...Regulatory and Compliance Infor mation Chapter 10...
Страница 251: ...REGULATORY AND COMPLIANCE INFORMATION PRODUCT REGULATORY COMPLIANCE MARKINGS 10 5...