2.
Connections & Settings
Connection
Description
Electrical Range
S1, S2
This channel reads the output of up to two
external analog sensors. It also pr/-12V
to power the attached sensor(s).
Input range: -10V to 10V
S3
This channel reads the output of an external
analog sensor. It also pr/-12V to power
the attached sensor.
Input range: -10V to 10V
S4
This channel reads the output of an external
analog sensor. It also pr/-12V to power
the attached sensor.
Input range: -10V to 10V
To ADC
Voltages read through S1, S2, S3 and S4 are
outputted via the “To ADC” connector to an
external data acquisition board.
Output range: -10V to 10V
Amplifier
Command
An analog voltage is applied on this channel. This
directly controls the output of the amp through
the “Amp Out” channel.
Acceptable Input range:
-10V to 10V
Current Sense
Indicates the current being drawn by the load
1A/V
To Load
The load to be driven is connected here.
Amp Out = Gain * CMD
where Gain is either 1 or 3,
and -10V <= CMD <= 10V
-24V to 24V
LED
LED Off = Over-heated / E-Stopped / No Power
LED On = Amp powered up and operational
Gain Toggle
Switch
Setting the toggle switch to the left position
selects a gain of 1 for the amplifier. Setting to
right implies a gain of 3.