Quanser AMPAQ-PWM Скачать руководство пользователя страница 8

Amplifier Specifications

Value

Amplifier Command Input

±

10 V

Current Sense Output

1 V = 2.1 A

Digital Inputs

Low-level: 0 V - 0.8 V
High-level: 2.0 V - 5.5 V

Digital Outputs

Low-level: 0 V - 0.6 V
High-level: 4.1 V - 5.2 V

Mass

10.4 kg

Dimensions

0.39 m

×

0.39 m

×

0.14 m

Environmental

• Standard rating
• Indoor use only
• Altitude up to 2000m
• Maximum relative humidity of 80% up to 31

C de-

creasing linearly to 50% relative humidity at 40

C

• Pollution Degree 2
• Mains supply voltage fluctuations up to

±

10% of the

nominal voltage

• Maximum transient overvoltage 2500V
• Marked degree of protection to IEC 60529: Ordinary

Equipment (IPX0)

Table 3.3: Amplifier Specifications

Caution:

Precaution must be taken during the connection of this equipment to the AC outlet to make sure
the grounding (earthing) is in place and the ground wire is not disconnected.

Caution:

Avoid covering the fan during operation to prevent premature thermal shutdown of the amplifier.

Caution:

Do not position the equipment so that it is difficult to operate the on/off switch.

Caution:

The AMPAQ-PWM devices are made to be used with Quanser designed experiment kits that have
particular actuators. Use caution if the AMPAQ-PWM is being used with your own actuator. Any
load to be used with the AMPAQ-PWM should have a minimum inductance of 0.1 mH.

Caution:

Do not use the cables provided with the AMPAQ-PWM to wire it to experiments that use a different
amplifier module. The AMPAQ-PWM can be used with such experiments only if plant specific
cables are available.

4

FUSE INSTALLATION

The AMPAQ-PWM has two 3.5 Amp fuses that protect the amplifier from overcurrent through the main power con-
nector. If you find your unit does not output power from the

To Load

connector, or otherwise stops functioning, check

the fuses.

Caution: Make sure the power to the amplifier is disconnected before changing any fuses!

Follow this procedure to install or replace the fuses in the AMPAQ-PWM:

AMPAQ-PWM User Manual

8

Содержание AMPAQ-PWM

Страница 1: ...USER MANUAL AMPAQ PWM Amplifier Set Up and Configuration CAPTIVATE MOTIVATE GRADUATE...

Страница 2: ...cycle must be sent to a WEEE collection and recycling center Proper WEEE disposal reduces the environmental impact and the risk to human health due to potentially hazardous substances used in such eq...

Страница 3: ...escription 4 2 Components 5 3 Specifications 7 4 Fuse Installation 8 5 Wiring Procedure 10 5 1 Cable Nomenclature 10 5 2 Typical Connections 11 6 Troubleshooting 12 7 Technical Support 12 AMPAQ PWM Us...

Страница 4: ...ace for increased flexibility current sensing capability and an auxiliary E Stop connector to allow a single E Stop button to stop multiple devices Figure 1 1 Quanser AMPAQ PWM Caution This equipment...

Страница 5: ...ibration status of the connected device i e Shake Table II 6 E Stop connector The AMPAQ PWM requires an E Stop emergency stop button to be connected If no E Stop button is connected the AMPAQ PWM is d...

Страница 6: ...a Front b Back Figure 2 1 AMPAQ PWM components a Front b Back Figure 2 2 AMPAQ PWM analog and digital sensor connectors AMPAQ PWM User Manual 6...

Страница 7: ...ing 3 75 A Fuses 3 5 A 250 V 3AG Slow Blow Protection Class Class I Table 3 1 AC Input Specifications PWM Output Specifications Value Maximum Continuous Output Current 3 75 A Maximum Peak Output Curre...

Страница 8: ...to prevent premature thermal shutdown of the amplifier Caution Do not position the equipment so that it is difficult to operate the on off switch Caution The AMPAQ PWM devices are made to be used wit...

Страница 9: ...holders and insert the new ones Figure 4 2 Replacing the fuse in the fuse holder 5 Ensure the fuse being installed is a 3 5 A 250 V 3AG Slow Blow fuse For example the following fuses are acceptable r...

Страница 10: ...AMPAQ PWM to the desired load c E Stop E Stop The E Stop must be connected to the AMPAQ PWM for proper operation The E Stop button locks in the dis abled position when pressed To release the E Stop t...

Страница 11: ...n Ca ble This cable connects the Digital I O connector on the AMPAQ PWM to a Q2 USB or QPIDe terminal board h Split Digital I O Cable Split 16 pin Ribbon Cable This cable connects the Digital I O conn...

Страница 12: ...he User Manual for that Quanser product have been made correctly If the Emergency stop switch is connected to the amplifier make sure the red button is in the upper position to enable the amplifier Th...

Страница 13: ...range of control peripherals includes amplifiers and data acquisition boards They can be purchased separately to control educational or research grade plants Mix and match these peripherals with Quan...

Отзывы: