Quanser AMPAQ-PWM Скачать руководство пользователя страница 13

Solutions for teaching and research. Made in Canada.

[email protected]     +1-905-940-3575     QUANSER.COM   

QPIDe

AMPAQ-L2

AMPAQ-L4

AMPAQ-PWM

Q2-USB

NI Terminal  

Board

Q8-USB

Q1-cRIO

Mix and match components and peripherals to suit your education or research needs

Quanser’s range of control peripherals includes amplifiers and data acquisition boards. They can be purchased  
separately to control educational or research-grade plants. Mix and match these peripherals with Quanser plants 
and control design software to accelerate control system design and implementation. 

To find the right peripherals for your teaching or research needs, please email [email protected].

©2016 Quanser Inc. All rights reserved. 

VoltPAQ-X1

VoltPAQ-X2

VoltPAQ-X4

Содержание AMPAQ-PWM

Страница 1: ...USER MANUAL AMPAQ PWM Amplifier Set Up and Configuration CAPTIVATE MOTIVATE GRADUATE...

Страница 2: ...cycle must be sent to a WEEE collection and recycling center Proper WEEE disposal reduces the environmental impact and the risk to human health due to potentially hazardous substances used in such eq...

Страница 3: ...escription 4 2 Components 5 3 Specifications 7 4 Fuse Installation 8 5 Wiring Procedure 10 5 1 Cable Nomenclature 10 5 2 Typical Connections 11 6 Troubleshooting 12 7 Technical Support 12 AMPAQ PWM Us...

Страница 4: ...ace for increased flexibility current sensing capability and an auxiliary E Stop connector to allow a single E Stop button to stop multiple devices Figure 1 1 Quanser AMPAQ PWM Caution This equipment...

Страница 5: ...ibration status of the connected device i e Shake Table II 6 E Stop connector The AMPAQ PWM requires an E Stop emergency stop button to be connected If no E Stop button is connected the AMPAQ PWM is d...

Страница 6: ...a Front b Back Figure 2 1 AMPAQ PWM components a Front b Back Figure 2 2 AMPAQ PWM analog and digital sensor connectors AMPAQ PWM User Manual 6...

Страница 7: ...ing 3 75 A Fuses 3 5 A 250 V 3AG Slow Blow Protection Class Class I Table 3 1 AC Input Specifications PWM Output Specifications Value Maximum Continuous Output Current 3 75 A Maximum Peak Output Curre...

Страница 8: ...to prevent premature thermal shutdown of the amplifier Caution Do not position the equipment so that it is difficult to operate the on off switch Caution The AMPAQ PWM devices are made to be used wit...

Страница 9: ...holders and insert the new ones Figure 4 2 Replacing the fuse in the fuse holder 5 Ensure the fuse being installed is a 3 5 A 250 V 3AG Slow Blow fuse For example the following fuses are acceptable r...

Страница 10: ...AMPAQ PWM to the desired load c E Stop E Stop The E Stop must be connected to the AMPAQ PWM for proper operation The E Stop button locks in the dis abled position when pressed To release the E Stop t...

Страница 11: ...n Ca ble This cable connects the Digital I O connector on the AMPAQ PWM to a Q2 USB or QPIDe terminal board h Split Digital I O Cable Split 16 pin Ribbon Cable This cable connects the Digital I O conn...

Страница 12: ...he User Manual for that Quanser product have been made correctly If the Emergency stop switch is connected to the amplifier make sure the red button is in the upper position to enable the amplifier Th...

Страница 13: ...range of control peripherals includes amplifiers and data acquisition boards They can be purchased separately to control educational or research grade plants Mix and match these peripherals with Quan...