17

AC-JSB-4

STEP SYSTEMS

Junction Box

Materials

Lid & Box

• High impact, corrosion resistant thermoplastic

• Weatherproof

• 1/2” UL approved, CSA Certified round cable 

liquid-tight strain

  relief connectors

• 1-1/2” terminal adapter hub 
Gasket

• Flexible PVC
Screws

• Brass

Warranty for Defects in Material and Workmanship

• Junction Boxes - 3 Years

STEP SYSTEMS

Control Panel

AC-CP-S-C-T

Specifications

Enclosure 

• Measures 10x8x4 inches (25.40x20.32x10.16 cm).  

NEMA 4X (ultraviolet stabilized thermoplastic with re-

movable flanges for outdoor or indoor use).

• Magnetic Motor Contactor controls pump by switching 

hot electrical lines

• HOA Switch for manual pump control (mounted on cir-

cuit board)

• Float Switch Terminal Block

• Alarm and Control Fuses

• Programmable Timer with separate variable controls al-

lows for setting the on and off times from .05 seconds to 

30 hours.

• Circuit Breaker provides pump disconnect and branch 

circuit protection

Power Supply

• Pump-120/208/240V, 7-15FLA

• Alarm-120V
Standard Alarm Package

• Red Alarm Beacon provides 360 visual check of alarm 

condition

• Exterior Horn Test/Normal/Silence Switch allows alarm 

horn to be silenced and testing of horn and light to en-

sure proper operation of alarm system

• Horn Silence Relay automatically resets alarm after 

alarm condition has been resolved (mounted on circuit 

board)

Warranty for Defects in Material and Workmanship

• Control Panel - 3 Years

Содержание AeroCell ATS-SCAT-86-AC-C750

Страница 1: ...ESTWOOD KY 40014 FAX 502 992 8249 www quanics net CLASS I NSF STD 40 WASTEWATER TREATMENT SYSTEM OPERATION MAINTENANCE MANUAL MANUFACTURED PRODUCTS BY QUANICSTM FIXED FILM MEDIA WASTEWATER TREATMENT SYSTEMS Revised August 2007 E n g i n e e r i n g Water S o l u t i o n s ...

Страница 2: ...ic Tank 3 Section 2 0 A300 8 Series Effluent Filter 3 Section 3 0 Dosing Tank 4 Section 4 0 Filtered Pump Vault 4 Section 5 0 Controls Pumps Floats 4 Section 6 0 Treatment Module 4 Section 7 0 Recirculation Device 5 TROUBLESHOOTING GUIDE 5 6 SAFETY 6 DRAWINGS TECHNICAL DATA 7 19 WIRING SCHEMATICS 20 21 DATA PLATES 21 ...

Страница 3: ...ms utilizing fixed film media The module s consist of a fiberglass tank s containing a pre determined amount of media Ef fluent is sprayed over the media utilizing specialized spay nozzles This patented delivery system evenly distributes wastewater to achieve the desired treatment levels The AeroCell utilizes open cell foam media The foam has a high porosity large surface area and ease of microbia...

Страница 4: ...nable float is down the pump will need to be activated manually by switching the HOA switch in the control panel to HAND 6 While the pump is running observe the spray nozzles in the treatment module for flow and pressure 7 While the pump is running observe the recirculation device for proper flow 8 Once the current operating condition of the system is established turn the HOA switch to the OFF pos...

Страница 5: ...ned 2 Remove the filter panel Rinse the filter plates with fresh water making sure all septage is rinsed back into the tank The filter plates should be cleaned until all slots are open and free of de bris 3 Replace the filter panel and remove the white maintenance plate Repeat steps 1 and 2 for the second filter panel Section 5 0 Controls Pump Floats 1 Inspect the floats for proper placement and m...

Страница 6: ...located at the proper level When the ball float is at its lowest position it should be located equal to or just above the on position of the timer enable float figure 1 2 Check that the design recirculation rates are maintained by observing the discharge through all five out falls of the recirculation assembly Adjust as needed by loosening the quick disconnects and leveling TROUBLESHOOTING GUIDE T...

Страница 7: ...ridge has been removed b Check the septic tank to see if it appears normal If not check with the PROPERTY OWNER to determine what inappropriate materials might have been added to the waste stream 3 Recirculation device is not splitting properly a Check the out falls for clogging b Check the device for level 4 Control panel malfunction a Check all fuses and breakers b Check originating power source...

Страница 8: ...sory personnel Follow these safety precautions when performing any excavation or construction work Follow all construction safety procedures during installation Follow electrical safety procedures during installation Fill all holes and depressions in and around the installation area remove and dispose of all debris from installation TECHNICAL DATA DRAWINGS INDEX ATS SCAT 8 AC C500 8 PDS ED 1 5 16 ...

Страница 9: ...uanics net autocad htm 750 GPD AeroCell System www quanics net autocad htm The septic tank shall have a minimum L W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio of equal to or greater than one ...

Страница 10: ...uanics net autocad htm 1250 GPD AeroCell System www quanics net autocad htm The septic tank shall have a minimum L W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio of equal to or greater than one ...

Страница 11: ...nics net autocad htm The septic tank shall have a minimum L W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio of equal to or greater than one 500 gallons per day 85ft3 of Bio COIR media 5 88 gpd ft3 hydraulic loading rate Four 120 degrees spray nozzles ...

Страница 12: ...L W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio of equal to or greater than one 750 gallons per day 138ft3 of Bio COIR media 5 88 gpd ft3 hydraulic loading rate Eight 120 degrees spray nozzles 1000 gallons per day 170ft3 of Bio COIR media 5 88 gpd ft3 hydraulic loading rate Eight 120 degrees spray nozzles ...

Страница 13: ... W ratio of equal to or greater than one The septic tank shall have a minimum L W ratio of equal to or greater than one 1250 gallons per day 223ft3 of Bio COIR media 5 88 gpd ft3 hydraulic loading rate Twelve 120 degrees spray nozzles 1500 gallons per day 255ft3 of Bio COIR media 5 88 gpd ft3 hydraulic loading rate Twelve 120 degrees spray nozzles ...

Страница 14: ...AT 886 BC C1250 1250 12 3 223 5 61 2500 1250 76 8 15 3 81 ATS SCAT 888 AC C1500 ATS SCAT 888 BC C1500 1500 12 3 255 5 88 3000 1500 76 8 15 3 98 The Zabel A300 8x18 VC model effluent filter is used in systems of 1200 gpd or less The A300 8x26 VC filter is used in systems up to 1800 gpd The septic tank shall have a minimum L W ratio of equal to or greater than one Features Effluent discharge and car...

Страница 15: ...on Outlet hub accepts 4 or 6 SCH 40 outlet pipe All Zabel Filters accept SmartFilter alarm switch GPD Maximum Gallons Per Day FS Filtration Size Warranty for Defects in Material and Workmanship Effluent Filters Limited Lifetime FILTERED PUMP VAULT Hanging FPV H44 4 FPV H56 4 High density non corrosive polyethylene plastic with stainless steel screws Features Hanging filtered pump vault installs in...

Страница 16: ... 3M 300 V SJOW jacketed 2 wire with ground Materials of Construction 300 grade stainless and cast iron Discharge 1 1 2 Warranty for Defects in Material and Workmanship All components 3 Years STEP SYSTEMS Effluent Discharges PDS ED 1 5 Materials Pipe 1 5 or 2 SCH 40 PVC 1 5 or 2 PVC flex tubing True Union Ball Valve PVC Plastic Double block full port design 1 5 or 2 slip slip hubs Fittings SCH 40 P...

Страница 17: ...Years PDS GT 2 0 STEP SYSTEMS Float Tree AC FT 3 Materials Pipe 1 5 or 2 SCH 40 PVC 1 5 or 2 PVC flex tubing True Union Ball Valve PVC Plastic Double block full port design 1 5 or 2 slip slip hubs Fittings SCH 40 PVC threaded slip adapter SCH 40 PVC slip slip adapter Warranty for Defects in Material and Workmanship All components 2 Years ...

Страница 18: ... electrical lines HOA Switch for manual pump control mounted on cir cuit board Float Switch Terminal Block Alarm and Control Fuses Programmable Timer with separate variable controls al lows for setting the on and off times from 05 seconds to 30 hours Circuit Breaker provides pump disconnect and branch circuit protection Power Supply Pump 120 208 240V 7 15FLA Alarm 120V Standard Alarm Package Red A...

Страница 19: ...charge Assembly 2 Years Float Valve Assembly 2 Years ATS GRD 100 80 20 N Materials Risers and Lids High density non corrosive polyethyl ene plastic Stainless steel screws Neoprene gasket IMPORTANT When adding risers together for deeper installations QUANICS does not recommend exceeding a maximum depth of 48 Neoprene gaskets must be installed as per instructions To prevent unauthorized entry instal...

Страница 20: ...19 Wiring Schematics ...

Страница 21: ...20 Consecutively Serial Numbered Data Plates Maintenance Sticker ...

Страница 22: ...TY OWNER Responsibilities The PROPERTY OWNER confirms that he has read and understands the AeroCell Bio COIR Operation Manual and agrees to operate the QUANICS AeroCell Bio COIR Advanced Treatment System in accordance with QUANICS s oper ating instructions Failure to use the system in accordance with the Operation Manual will void all warranties All repairs required to restore the system to normal...

Страница 23: ...om the date of installation pumps for a period of three years from the date of installation and AeroCell Bio COIR foam for a period of ten years from the date of installation Failed warranted parts shall be prorated over the period of use with cost calculated at the list price at the time of failure Discontinued parts will be replaced with the closest current QUANICS equivalent In no event shall Q...

Страница 24: ...OX 1520 PHONE 502 992 8200 6244 OLD LAGRANGE ROAD 1 877 QUANICS CRESTWOOD KY 40014 FAX 502 992 8249 www quanics net Treatment system service provider 082707 326 E n g i n e e r i n g Water S o l u t i o n s ...

Отзывы: