CONNECT LED
LED
PATTERN
LED
MEANING
ACTION
OFF
⚫
Wi-Fi off and not configured.
-
WHITE
⚪
Wi-Fi configured and connected to the
cloud.
-
WHITE
flashing
“
⚪
”
The device is in hotspot mode for Wi-Fi
configuration using the app.
-
YELLOW
flashing
“
🟡
”
Ongoing pairing establishment between two
CubicSecures, one for cold water and one
for hot water.
-
YELLOW/
BLUE
flashing
“
🟡
”
“
🔵
”
Pairing completed between the hot and cold
water devices. The connection is made from
the cold water device which flashes
YELLOW/ BLUE.
-
YELLOW/
RED
flashing
“
🟡
”
“
🔴
”
Pairing completed between the hot and cold
water devices. The connection is made from
the hot water device which flashes
YELLOW/RED.
-
GREEN
flashing
“
🟢
”
Hot/cold water pairing has been successful
and is completed.
-
RED
flashing
“
🔴
”
No internet or cloud connection.
Check router firewall or redo
app setup.
LEAKAGE ALARMS
LEAKAGE
TYPE
FLOW
RATE
[l/h]
DESCRIPTION
Micro leakage > 0.01
Detected by the valve being automatically closed daily to measure a
pressure drop above 0.5 bar for a maximum of 45 seconds.
Medium
leakage
> 6
The device alarms and shuts off the water after a continuous flow for
at least 45 minutes.
Large leakage > 1500
The device alarms and closes the valve after a continuous flow over
1500 l/h for at least 90 seconds.
Note that a larger leakage alarm will always override a smaller leakage detection. Above thresholds can
be modified using the mobile application.
Details are subject to change, check the latest version
.
The company is not liable for possible errors and/or misprints.