Installing the Library
XLS Library Site Planning Guide
3-7
3.2
Environmental Specifications
Before installing the XLS, confirm that the intended location conforms to the
environmental specifications listed in
3.3
Power Requirements
The XLS operates from the single-phase alternating current power sources (mains) shown
in
.
The base library includes a 20-amp switch/circuit breaker. (Power is connected to the base
library only; the MEM2 cabinet gets its power from the base library.) Other than selecting
the appropriate AC power cord (see
), the XLS requires no
changes to operate from any input voltage within the rated line voltage.
Parameter
Operating
Non-operating
Ambient temperature
+5°C to +32°C
(+41°F to +90°F)
–20°C to +60°C
(–4°F to +140°F)
Temperature gradient
(maximum)
1°C/minute, 10°C/hour
(2°F/minute, 18°F/hour)
1°C/minute, 20°C/hour
(2°F/minute, +36°F/hour)
Relative humidity
(non-condensing)
20% to 80%
10% to 90%
Wet bulb temperature
26°C (79°F) maximum
29°C (84°F) maximum
Altitude
–1000 to +10,000 feet
–304.8 to +3,048 meters
–1,000 to +40,000 feet
–304.8 to +12,192 meters
Table 3-3
Environmental specifications
CAUTION
To prevent interference with the optical barcode reader, light curtain
sensors, and cartridge present sensors, do not install the XLS in areas
exposed to direct sunlight.
Rated Line
Voltage
Maximum
Operating Line
Voltage
Minimum
Operating Line
Voltage
Line Frequency
Range
100–240 VAC
264 VAC
105 VAC
48–62 Hz
Table 3-4
XLS mains requirements
Содержание XLS-810160
Страница 1: ...XLS 810160 XLS 810240 Tape Libraries Site Planning Guide Document No 501804 Rev 07 01 19...
Страница 6: ...Table of Contents vi 501804 Rev 07 01 19 Notes...
Страница 10: ...1 1 About the XLS 1 4 501804 Rev 07 01 19 Figure 1 3 LRM with one MEM2...
Страница 22: ...3 4 Cooling Requirements 3 10 501804 Rev 07 01 19 Notes...