background image

3.1 Floor Space and Floor Loading

3-2

501804  Rev. 07-01-19

3.1.1

XLS-810160/810240

This section provides information about the dimensions and floor space requirements of 
the XLS-810160/810240.

XLS-810160/810240 Dimensions

Figure 3-1

 shows the dimensions of the XLS-810160/810240 base unit in inches and 

centimeters.

Figure 3-1

External dimensions of the XLS-810160/810240

78.0 in (199 cm)

36 in (91 cm)

24 in (61 cm)

Содержание XLS-810160

Страница 1: ...XLS 810160 XLS 810240 Tape Libraries Site Planning Guide Document No 501804 Rev 07 01 19...

Страница 2: ...keep the information contained in this document current and accurate as of the date of publication or revision However no guarantee is given or implied that the document is error free or that it is ac...

Страница 3: ...vice to others European Union Directive 89 336 EEC and Standard EN55022 Electromagnetic Compatibility This product has been tested and is certified to be compliant with the Class A provisions of the U...

Страница 4: ...rical and electronic equipment in accordance with the European Directive The compliance date is July 1 2006 at which time Qualstar will certify that its tape library products are compliant with the Ro...

Страница 5: ...ary 2 1 2 1 Unloading the Library 2 1 2 2 Moving the Library 2 1 2 2 1 Door Clearance 2 2 3 Installing the Library 3 1 3 1 Floor Space and Floor Loading 3 1 3 1 1 XLS 810160 810240 3 2 3 1 2 Media Exp...

Страница 6: ...Table of Contents vi 501804 Rev 07 01 19 Notes...

Страница 7: ...rary Considerations for installing the library For more information see Chapter 3 Installing the Library A check list of the components options and accessories needed to install an XLS library For mor...

Страница 8: ...artridges and up to two 10 slot I O ports As an option one Media Expansion Modules MEM can be installed on the left side of the XLS 810160 810240 See Section 1 1 2 on page 1 3 for more information Fig...

Страница 9: ...sion Module MEM includes a rotating motor driven carousel containing cartridge slots The XLS 85000 MEM2 can store up to 535 cartridges The XLS 810160 810240 can be expanded by adding one XLS 85000 MEM...

Страница 10: ...1 1 About the XLS 1 4 501804 Rev 07 01 19 Figure 1 3 LRM with one MEM2...

Страница 11: ...y that the truck be equipped with a lift gate or ramp to unload the equipment to ground level where it can be removed from the pallet and moved on its casters Difficult entry to building If the access...

Страница 12: ...oute for adequate clearance Confirm that the door frames are square and that sides are parallel The unpacked dimensions are 810160 and 810240 23 1 x 34 8 inches 59 x 89 cm With POD attached 30 4 x 34...

Страница 13: ...the following hardware XLS 810160 or XLS 810240 including an expansion pod See Section 3 1 1 on page 3 2 XLS 85000 Media Expansion Module MEM2 See Section 3 1 2 on page 3 4 Before moving the XLS to it...

Страница 14: ...information about the dimensions and floor space requirements of the XLS 810160 810240 XLS 810160 810240 Dimensions Figure 3 1 shows the dimensions of the XLS 810160 810240 base unit in inches and cen...

Страница 15: ...tallation or in the future consider the recommended installation order 1 Install the base unit 2 Install the expansion pod on the left side of the base Number of units Cabinets only Cabinets with 24 i...

Страница 16: ...pod is installed 3 1 2 Media Expansion Module MEM Both LRMs can be expanded by adding one XLS 85000 MEM2 on the left side If you plan to install a MEM whether during the initial installation or in th...

Страница 17: ...y XLS Library Site Planning Guide 3 5 MEM Dimensions Figure 3 3 shows the dimensions of the XLS 85000 MEM2 in inches and centimeters Figure 3 3 External dimensions of the XLS 85000 MEM2 78 in 199 cm 3...

Страница 18: ...Rev 07 01 19 Service Access Requirements for a MEM Figure 3 4 shows the service access requirements for a XLS 85000 MEM2 assuming that the door is open Figure 3 4 Service access requirements for a XL...

Страница 19: ...e within the rated line voltage Parameter Operating Non operating Ambient temperature 5 C to 32 C 41 F to 90 F 20 C to 60 C 4 F to 140 F Temperature gradient maximum 1 C minute 10 C hour 2 F minute 18...

Страница 20: ...ut module come supplied with two power cords The cords are three conductor 14 AWG SJT PVC jacketed cords terminated with an IEC 60320 C 19 type connector at the XLS end Table 3 5 lists the power cords...

Страница 21: ...urce to reduce the peak AC input current The integral circuit breaker will trip at 20 amps In general Qualstar recommends 220 volt input power Using a 220 volt source will prevent input power from bei...

Страница 22: ...3 4 Cooling Requirements 3 10 501804 Rev 07 01 19 Notes...

Страница 23: ...ape drives and cartridges connect the SCSI or Fibre Channel cables and configure the logical libraries 4 Item Provided by Notes LRM Qualstar Built and pre tested to customer specifications includes va...

Страница 24: ...tomer Refer to the installation plan to determine how many SCSI cables are required The tape drives use HD68 connectors while the HBAs in the XLS use VHDCI connectors Uninterruptible power supply UPS...

Отзывы: