The display should now show SF 10 as shown in the picture below. This indicates the Safety
Factor is 10 percent.
Use the UP or DOWN button to change this value to 15. Press the
Extra Cycle Button once to continue when finished.
The display should now show DO 14 as shown in the picture below. This indicates the Day
Override is 14 days the system will regenerate on the 14
TH
day if the meter does not
otherwise automatically initiate a regeneration based on gallons used.
Do not change this
value, and press the Extra Cycle Button once to continue.
The display should now show RT 2:00 as shown in picture below. This indicates the system will
regenerate at 2:00AM, assuming the system clock is set accurately.
Press the Extra Cycle
Button once to continue.