› G e n e r a l r e f e r e n c e
Please take a moment to review this page in order to
familiarize yourself with these four ports on the valve
and the programming values below. It is crucial not to
mistake the inlet port with the outlet port. Mistaking
and reversing the inlet and outlet ports will lead to fail-
ure of your softener system.
As you work through this guide, please make sure
to follow all instructions exactly and to make special
note of the bolded instructions and warning symbols.
PdF viewers may click underlined text to jump to
that page or the page number in the bottom corner
of every page to jump to the table of contents.
All
our installation guides may be found on our site under
“Information.”
› Q u I c k s ta r t
To the right are the program settings for your soften-
er.
If not all of the values are filled in, you can
calculate the missing values from the exercise on
pages 6 and 7 of this guide.
There we will cover
identifying the 3 essential values of
H - HardneSS
,
c - unIt caPacItY
, and
BF - BrIne FIll
. The
remaining values that are already filled in are general
standards for all softener sizes and hardness levels.
MaSter ProGraMMInG Mode:
To enter in/
check the adjacent values of your system, follow
these steps: With either the up or down arrow
button, change the clock to 12:01 PM, set the time
by clicking the left-most CYCLE / REGEN button,
and then hold both the up and down arrow buttons
for 5 seconds to enter master programming mode.
Change values with the arrow buttons and set each
value and advance to the next setting by clicking the
CYCLE / REGEN button.
A more in-depth guide to programming the Fleck
2510 SXT is provided beginning on
o u t l e t
I n l e t
b r I n e
d r a I n
s e t t I n G
I n P u t Va l u e
DF - Display Format
GAL - Gallons
VT - Valve Type
dF1b
CT - Control Type
Fd - Flow Delayed
NT - Number of Tanks
1
c - unIt caPacItY
,000 Grains
H - HardneSS
Grains per Gallon
RS - Reserve Selection
SF
SF - Safety Factor
15%
DO - Day Override
14 Days
RT - Regen Time
2:00 AM
BW - Backwash
10 Minutes
BD - Brine Draw
60 Minutes
RR - Rapid Rinse
12 Minutes
BF - BrIne FIll
Minutes
FM - Flow Meter Type
t0.7 or P0.7
Job Number:
Model Number:
Mineral Tank Size:
FM - Flow Meter Type
t0.7
P0.7