Help: 888-426-5001
f I G u r e 14 - a
f I G u r e 14 - b
f I G u r e 14 - c
f I G u r e 14 - d
7 ›Pro G r a M M I n G t H e f l ec k 2 510 sx t Va lV e
1) Loosen the screw on the front of the valve and
remove the valve front cover to expose the SXT
controller and prepare for programming as seen
in Figure 14-A
2) To begin programming, first plug in your
2510SXT Valve to a nearby wall outlet. The
system will illuminate 4 digits. The system will
show the time of day and the amount of gallons
remaining before the next regneration. This
display will switch between these values about
every 10 seconds
3) Set the time on the system to 12:01 PM by
pressing either the UP or DOWN button as
shown in Figure 14-B.
i
Be careful to confirm
the presence of the PM symbol in the top
right corner.
You may hold the button to allow
the time to scroll faster. Once the time display is
set to 12:01 PM, press the REGEN button once
as shown in Figure 14-C
4) To enter MASTER PROGRAMMING MODE,
press the UP and DOWN buttons TOGETHER
and HOLD both for 5 seconds as shown in
Figure 14-D
f I G u r e 14 - e
f I G u r e 14 - f
5) The display should now show
dF / Gal
as shown
in Figure 14-E. This indicates U.S. Operational
Mode measuring consumption in gallons.
do
not change this value and press the reGen
button once to advance to the next setting
6) The display should now show
Vt / dF1b
as
shown in Figure 14-F. This indicates Regeneration
Flow Downflow Single Backwash. Do not change
this value and press the REGEN button to advance
to the next setting