Model EQ10
Installation, Operation and Maintenance
Page 5
Rev. 11/30/2020
EQ
10-IOM-Q.
doc
A
NCHORING
4) The anchor bolts must be installed at least 8”
from any crack, edge, or expansion joint.
5) Use a concrete hammer drill with a 3/4-inch
carbide bit. Tip diameter should conform to ANSI
Standard B94.12-1977 (.775 to .787). Do not use
excessively worn bits or bits which have been
incorrectly sharpened. A core bit may be
necessary if an obstruction is encountered.
Never substitute with shorter anchor.
6) Recheck “Inside of Columns” dimension,
Fig 1
.
Drill the anchor holes using the base plate as a
template. Drill through the floor if possible or to a
depth of 5 inches minimum.
7) Vacuum dust from the hole for proper holding
power.
8) Shim both columns to plumb using the shims
provided as shown in
Fig 2
. DO NOT shim more
than 1/2" at any given point. Use a level no less
than 24” in length to plumb columns.
9) Assemble washer and nut to anchor with nut just
below impact section of bolt. Drive anchor into
hole until nut and washer contact base.
Fig. 3 –
Column Shimming
10) Tighten power column anchors and recheck
column for plumb. Re-shim if necessary. Torque
to 150 foot-pounds to set anchors.
O
VERHEAD
/L
IMIT
S
WITCH
11) Raise and install Overhead Assembly using M12
x 30 Hex Bolts.
12) Install Overhead Limit Switch and Shutoff Bar
under the Overhead Beam as shown in
Fig 4.
13) Check idler column shimming. Use additional
shims (
see Fig 3
) to remove any gaps that may
have been created while installing overhead
beam. Tighten anchor bolts and re-check column
for plumb. Torque to 150 foot-pounds.
Fig. 4 - Limit Switch
S
YNCHRONIZER
C
ABLES
14) Manually raise each carriage into the second
lock position.
15)
At the upper beam sheave locations
disassemble and reassemble the cable trapping
rod to install the cable onto the sheave as shown
in
Fig 5
. At base of columns, bottom sheave will
need to be removed then reassembled.
Fig. 5-Cable Trapping
16) Attach one end of synchronizing cable to
carriage. See
Fig 6
for proper attachment.
17) Route cable up and over sheave in overhead.
Follow across to other sheave on opposite
column. Route down through carriage to sheave
in bottom of column. Route under sheave and up
to cable attachment. Use
Fig 6
for proper
attachment.
18) Repeat for opposite side.