Quadra-Fire  •  Columbia Bay Insert  •  7002-109  Rev. H  •  10/08

20

H. Mineral Wool

I. Blower 

Installation

Included in kit:  

Blower.

Tools required:

 Powered Phillips head screwdriver.

Figure 8.23

Figure 8.24  

Figure 8.25

Explosion  Risk.

•  Follow ember placement instructions in manual.

•  Do NOT place embers directly over burner ports.

•  Replace ember material annually.

Improperly placed embers interferes with proper burner 
operation.

WARNING

Place individual pieces of embers in front of and around the 
gas log where they can be seen. Space them so that gas 
can contact them on all sides. Avoid stacking the embers 
on top of each other. 

Figure 8.22

Note: 

Do not block gas ports.

Turn off gas and disconnect appliance from electricity. 
Remove logs and burner from appliance.  Remove blower 
access cover in bottom of firebox by removing the screws.  
Retain screws for reassembly.

Disconnect wires from the snap disk on back of access 
cover. 

Lift blower off of studs and pull through opening. 

Содержание Vented Gas Fireplace Heater COLBAY-INS

Страница 1: ...ded Read understand and follow these instructions for safe installation and operation In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter a CO detec...

Страница 2: ...if none follow The National Fuel Gas Code ANSI Z223 1 and NFPA 54 or Canadian Installation Codes CAN CGA B149 NOTE Have the gas supply line installed in accordance with local building codes by a qual...

Страница 3: ...r Replacement 11 D Gas Pressures 12 E Gas Connection 12 7 Electrical Information A Recommendation for Wire 14 B Connecting to the Appliance 14 C Standing Pilot Ignition System Wiring 14 8 Appliance Se...

Страница 4: ...ble sections of Gas Burn ing Heating Appliances for Manufactured Homes and Recreational Vehicles and Gas Fired Appliances for Use at High Altitudes A Appliance Certification E Non Combustible Material...

Страница 5: ...Carefully remove the appliance and components from the packaging Remove cast door and glass and set aside on protective surface Remove log set and component pack from firebox Report to your dealer any...

Страница 6: ...llation may vary due to individual design preference Fire Risk Provide adequate clearance Around air openings To combustibles For service access Locate appliance away from traffic areas A Selecting Ap...

Страница 7: ...12 to 12 12 4 0 Over 12 12 to 14 12 5 0 Over 14 12 to 16 12 6 0 Over 16 12 to 18 12 7 0 Over 18 12 to 20 12 7 5 Over 20 12 to 21 12 8 0 Figure 4 1 Minimum height from roof to lowest discharge opening...

Страница 8: ...rdance with your installation plans See instructions in this manual to do so Slide the unit back into the fireplace Attach transition assembly to the appliance Rotate transi tion assembly latches and...

Страница 9: ...h the venting kit THIS OPTION SHOWS THE AIR INLET TERMINATING IN THE CHIMNEY Fire Hazard Asphyxiation Risk The exhaust pipe must only be connected to the exhaust starting collar of the unit and the ce...

Страница 10: ...chusetts installation must be performed by a licensed plumber or gas fitter B Converting to LP Gas A Fuel Conversions Before making gas connections ensure that appliance be ing installed is compatible...

Страница 11: ...l F to the valve body where it can be seen Fill out the conversion label and attach it to the valve cover Fire Risk Explosion Risk Disconnect any electrical cords and turn off gas supply to unit befor...

Страница 12: ...ppliance Before making the gas connection ensure that the appliance you are installing is designed for the type of gas being supplied This information can be found on the ratings label under the appli...

Страница 13: ...flames A small amount of air will be in the gas supply lines When first lighting appliance it will take a short time for air to purge from lines When purging is complete the appliance will light and o...

Страница 14: ...l Information NOTE This appliance must be electrically wired and grounded in accordance with local codes or in the absence of local codes with National Electric Code ANSI NFPA 70 latest edition or the...

Страница 15: ...SURE INLET PRESSURE PUSH BUTTON IGNITOR THERMOPILE IGNITOR PILOT THERMOCOUPLE CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous oper...

Страница 16: ...ries Install approved accessories per instructions included with accessories See Service Parts List for appropriate accessories Shock or fire risk Use ONLY optional accessories approved for this appli...

Страница 17: ...power cord restraint found in the appliance com ponent bag Cord is shipped exiting the right side of the appliance but can be routed in either direction A notch will be needed in the trim piece for t...

Страница 18: ...LE SUPPORTS SUPPORTS Lift the baffle slightly and install the rear brick panel Rest baffle on rear brick panel Install right brick panel BAFFLE BAFFLE REAR BRICK PANEL REAR BRICK PANEL BRICK CLIPS BRI...

Страница 19: ...s appliance and reduce sooting Complete log installation 4 4 5 5 1 1 3 3 Figure 8 15 Figure 8 18 Figure 8 16 Figure 8 19 Left side Right side Figure 8 17 Figure 8 20 Figure 8 21 2 2 After installing b...

Страница 20: ...es with proper burner operation WARNING Place individual pieces of embers in front of and around the gas log where they can be seen Space them so that gas can contact them on all sides Avoid stacking...

Страница 21: ...the reverse of removal Figure 8 28 Blower Wiring Diagram F 1 4 in 6 mm female spade M 1 4 in 6 mm male spade Disconnect wires from the blower Remove grommet retainer from old blower and install on new...

Страница 22: ...om the control panel Figure 8 30 Figure 8 31 Figure 8 32 Note Do not close so much as to cause a sooty flame Improper adjustment can cause sooting in the firebox and or on the outside of a house with...

Страница 23: ...ating appliance Only use glass door certified for use with appliance Glass replacement should be done by qualified technician Improper installation adjustment alteration service or maintenance can cau...

Страница 24: ...ct the power from the appliance 4 Open the door of the appliance May need to remove face front first 5 Push in gas control knob slightly and turn clockwise to the OFF position Do not force 6 Wait five...

Страница 25: ...ION Prevent accidental appliance operation when not attended Unplug or remove batteries from remote control if absent or if appliance will not be used for an extended period of time Property damage po...

Страница 26: ...flame impingement Ensure that the thermocouple connection at the gas valve is fully inserted and tight hand tighten plus 1 4 turn Disconnect the thermocouple from the valve place one millivolt meter...

Страница 27: ...in tank Check the LP propane tank Refill the fuel tank b Inner vent pipe leaking exhaust gases back into the system Check venting system for damage Replace repair improperly assembled pipe sections c...

Страница 28: ...qualified technician recommended Check Condition of glass glass assembly and glass seal Obstructions of combustion and ventilation air Obstructions of termination cap Burner ignition and operation Bur...

Страница 29: ...nt as neces sary 2 Replace appliance if firebox has been perforated Burner Ignition and Operation 1 Verify burner is properly secured and aligned with pilot or igniter 2 Clean off burner top inspect f...

Страница 30: ...ESSIBLE HERE WHEN SHIPPED ELECTRICAL CONNECTION AND GAS CONNECTION EXTEND FROM HERE RIGHT SIDE OF STOVE F G A B C E D 12 12 Reference Materials A Appliance Dimension Diagram Dimensions are actual appl...

Страница 31: ...em Components Description HHT Component LINK DV4 30B Includes one piece 3 in x 30 ft Flex one piece 3 in x 4 ft Flex Cap Adapter Linear to Coaxial with Flashing Dura Vent GS Catalog 923GK Colineal Fle...

Страница 32: ...v H 10 08 32 R 2 13 14 15 6 7 8 10 12 11 9 1 3 4 5 Service Parts Diagram Columbia Bay Insert COLBAY INS Beginning Manufacturing Date April 2003 Ending Manufacturing Date ______ Service Parts Part numb...

Страница 33: ...bly with Glass DOOR COLBAY INS 12 Door Crown 462 0150 13 Door Face Access 7008 117 14 Burner with Neck Assembly 7002 005 Y 15 Refractory Support Right 7002 129 Anti Bang Kit 842 5040 Baffle Seal 7002...

Страница 34: ...ay be ordered from an authorized dealer Stocked at Depot ITEM DESCRIPTION SERIAL PART NUMBER 1 Pilot Assembly NG for LP use LP Pilot Orifice 230 1781 Y Pilot Assembly NG with Injector 842 4280 Y 2 Spe...

Страница 35: ...rable under this warranty is limited to the purchase price of the product In no event shall HHT be liable for any incidental or consequential damages caused by defects in the product Adjustments regul...

Страница 36: ...ized and approved by HHT in writing This warranty does not apply to non HHT venting components hearth components or other accessories used in conjunction with the installation of this product This war...

Страница 37: ..._____________________________________________________________ ________________________________________________________________________________ Printed in U S A Copyright 2008 This product may be cover...