background image

Quadra-Fire  •  Columbia Bay Insert  •  7002-109  Rev. H  •  10/08

2

APPROVED FOR CANADA AND USA TO:
ANSI Z21.88b-2003 / CSA 2.33b-2003 Vented Gas Fireplace Heate r, and applicable sections of UL307b Gas Burning
Heating Appliances for Manufactured Homes and Recreational Vehicles, CAN/CG A 2.17-M91 “Gas Fired Appliances
for use at High Altitudes.”
This appliance is manufactured for operation with Natural Gas. For conversion to propane the Manufacturer’s kit
provided with the stove must be used in conjuntion with the instructions in the owner's manual.
This vented gas fireplace heater is not for use with air filters.
This appliance may be installed in a bedroom or bedsitting room; in Canada remote thermostat installation is
required.

FAN TYPE VENTED CIRCULATOR Blower Electrical Rating115 V., 1.5 Amps, 60 Hz, 150 Watts

For use with Natural Gas

For use with Propane

"0-2000’

"0-2000’

Input Rate on “HI” (BTU/Hr)

30,000

28,000

Input Rate on “LO” (BTU/Hr)

22,500

22,650

Main Burner Orifice (DMS)

36

52

Minimum Inlet Pressure (Inches W.C.)

4.5”

11”

Maximum Inlet Pressure (Inches W.C.)

7.0”

14”

Manifold Pressure on “HI” (Inches W.C.)

3.5”

10”

Efficiency up to

82.5%

81%

AFUE

71%

72.5%

2005

2006

2007

Feb

Mar

Apr

May

Jun

Jul

Aug

Sep

Oct

Nov

Dec

Jan

DO NOT REMOVE THIS LABE

L

MADE IN U.S.A.

Date of Manufacture / Date du Manufacturier

MINIMUM CLEARANCES TO COMBUSTIBLES

This appliance equipped for altitudes 0-2000’ (0-610m) in USA; and in Canada for altitudes of 0-4500’ (0-1370m). In USA for
Altitudes above 2000’, the vent configuration, orifice, or combination of both may need to be changed. See Owner’s Manual for
information on making these changes.

This appliance must be installed in accordance with local codes, if any (and Commonwealth of Massachusetts approved); if
none, follow The National Fuel Gas Code,ANSI Z223.1 and NFPA 54; or Canadian Installation Codes CAN/CGA-B149.
NOTE: Have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or
licensed as required by the locality. (In the Commonwealth of Massachusetts, installation must be performed by a licensed
plumber or gas fitter.)

Manufactured by:

7031-221

P.4.1-02 Canada Minimum Pipe 69% NG / 71% LP

Report No. / Rapport Numero

061-S-63-5

MODEL: XXXXXXX

VENTED GAS APPLIANCE

NOT FOR USE WITH SOLID FUEL

SERIAL

NO.

XXX

Tested and

Listed by

Beaverton

Oregon USA

OMNI- Test Laboratories, Inc .

C

R

and Welcome to the Quadra-Fire Family

!

Hearth & Home Technologies welcomes you to our tradi-
tion of excellence!  In choosing a Quadra-Fire appliance, 
you have our assurance of commitment to quality, durabil-
ity, and performance.

This commitment begins with our research of the market, 
including ‘Voice of the Customer’ contacts, ensuring we 
make products that will satisfy your needs. Our Research 
and Development facility then employs the world’s most 
advanced technology to achieve the optimum operation of 
our stoves, inserts and fi replaces.  And yet we are old-fash-
ioned when it comes to craftsmanship.  Each appliance 

is meticulously fabricated and gold and nickel surfaces 
are hand-fi nished for lasting beauty and enjoyment.  Our 
pledge to quality is completed as each model undergoes 
a quality control inspection.   From design, to fabrication, 
to shipping: Our guarantee of quality is more than a word, 
it’s Quadra-Fire tradition, and we proudly back this tradition 
with a Limited Lifetime Warranty.  

We wish you and your family many years of enjoyment in 
the warmth and comfort of your hearth appliance.  Thank 
you for choosing Quadra-Fire.

SAMPLE OF SERIAL NUMBER / SAFETY LABEL

LOCATION: HANGING ON A CHAIN ON BACK OF APPLIANCE

Manufactured 
Date

Serial Number

Model Name

Test Lab & 
Report No.

Содержание Vented Gas Fireplace Heater COLBAY-INS

Страница 1: ...ded Read understand and follow these instructions for safe installation and operation In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter a CO detec...

Страница 2: ...if none follow The National Fuel Gas Code ANSI Z223 1 and NFPA 54 or Canadian Installation Codes CAN CGA B149 NOTE Have the gas supply line installed in accordance with local building codes by a qual...

Страница 3: ...r Replacement 11 D Gas Pressures 12 E Gas Connection 12 7 Electrical Information A Recommendation for Wire 14 B Connecting to the Appliance 14 C Standing Pilot Ignition System Wiring 14 8 Appliance Se...

Страница 4: ...ble sections of Gas Burn ing Heating Appliances for Manufactured Homes and Recreational Vehicles and Gas Fired Appliances for Use at High Altitudes A Appliance Certification E Non Combustible Material...

Страница 5: ...Carefully remove the appliance and components from the packaging Remove cast door and glass and set aside on protective surface Remove log set and component pack from firebox Report to your dealer any...

Страница 6: ...llation may vary due to individual design preference Fire Risk Provide adequate clearance Around air openings To combustibles For service access Locate appliance away from traffic areas A Selecting Ap...

Страница 7: ...12 to 12 12 4 0 Over 12 12 to 14 12 5 0 Over 14 12 to 16 12 6 0 Over 16 12 to 18 12 7 0 Over 18 12 to 20 12 7 5 Over 20 12 to 21 12 8 0 Figure 4 1 Minimum height from roof to lowest discharge opening...

Страница 8: ...rdance with your installation plans See instructions in this manual to do so Slide the unit back into the fireplace Attach transition assembly to the appliance Rotate transi tion assembly latches and...

Страница 9: ...h the venting kit THIS OPTION SHOWS THE AIR INLET TERMINATING IN THE CHIMNEY Fire Hazard Asphyxiation Risk The exhaust pipe must only be connected to the exhaust starting collar of the unit and the ce...

Страница 10: ...chusetts installation must be performed by a licensed plumber or gas fitter B Converting to LP Gas A Fuel Conversions Before making gas connections ensure that appliance be ing installed is compatible...

Страница 11: ...l F to the valve body where it can be seen Fill out the conversion label and attach it to the valve cover Fire Risk Explosion Risk Disconnect any electrical cords and turn off gas supply to unit befor...

Страница 12: ...ppliance Before making the gas connection ensure that the appliance you are installing is designed for the type of gas being supplied This information can be found on the ratings label under the appli...

Страница 13: ...flames A small amount of air will be in the gas supply lines When first lighting appliance it will take a short time for air to purge from lines When purging is complete the appliance will light and o...

Страница 14: ...l Information NOTE This appliance must be electrically wired and grounded in accordance with local codes or in the absence of local codes with National Electric Code ANSI NFPA 70 latest edition or the...

Страница 15: ...SURE INLET PRESSURE PUSH BUTTON IGNITOR THERMOPILE IGNITOR PILOT THERMOCOUPLE CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous oper...

Страница 16: ...ries Install approved accessories per instructions included with accessories See Service Parts List for appropriate accessories Shock or fire risk Use ONLY optional accessories approved for this appli...

Страница 17: ...power cord restraint found in the appliance com ponent bag Cord is shipped exiting the right side of the appliance but can be routed in either direction A notch will be needed in the trim piece for t...

Страница 18: ...LE SUPPORTS SUPPORTS Lift the baffle slightly and install the rear brick panel Rest baffle on rear brick panel Install right brick panel BAFFLE BAFFLE REAR BRICK PANEL REAR BRICK PANEL BRICK CLIPS BRI...

Страница 19: ...s appliance and reduce sooting Complete log installation 4 4 5 5 1 1 3 3 Figure 8 15 Figure 8 18 Figure 8 16 Figure 8 19 Left side Right side Figure 8 17 Figure 8 20 Figure 8 21 2 2 After installing b...

Страница 20: ...es with proper burner operation WARNING Place individual pieces of embers in front of and around the gas log where they can be seen Space them so that gas can contact them on all sides Avoid stacking...

Страница 21: ...the reverse of removal Figure 8 28 Blower Wiring Diagram F 1 4 in 6 mm female spade M 1 4 in 6 mm male spade Disconnect wires from the blower Remove grommet retainer from old blower and install on new...

Страница 22: ...om the control panel Figure 8 30 Figure 8 31 Figure 8 32 Note Do not close so much as to cause a sooty flame Improper adjustment can cause sooting in the firebox and or on the outside of a house with...

Страница 23: ...ating appliance Only use glass door certified for use with appliance Glass replacement should be done by qualified technician Improper installation adjustment alteration service or maintenance can cau...

Страница 24: ...ct the power from the appliance 4 Open the door of the appliance May need to remove face front first 5 Push in gas control knob slightly and turn clockwise to the OFF position Do not force 6 Wait five...

Страница 25: ...ION Prevent accidental appliance operation when not attended Unplug or remove batteries from remote control if absent or if appliance will not be used for an extended period of time Property damage po...

Страница 26: ...flame impingement Ensure that the thermocouple connection at the gas valve is fully inserted and tight hand tighten plus 1 4 turn Disconnect the thermocouple from the valve place one millivolt meter...

Страница 27: ...in tank Check the LP propane tank Refill the fuel tank b Inner vent pipe leaking exhaust gases back into the system Check venting system for damage Replace repair improperly assembled pipe sections c...

Страница 28: ...qualified technician recommended Check Condition of glass glass assembly and glass seal Obstructions of combustion and ventilation air Obstructions of termination cap Burner ignition and operation Bur...

Страница 29: ...nt as neces sary 2 Replace appliance if firebox has been perforated Burner Ignition and Operation 1 Verify burner is properly secured and aligned with pilot or igniter 2 Clean off burner top inspect f...

Страница 30: ...ESSIBLE HERE WHEN SHIPPED ELECTRICAL CONNECTION AND GAS CONNECTION EXTEND FROM HERE RIGHT SIDE OF STOVE F G A B C E D 12 12 Reference Materials A Appliance Dimension Diagram Dimensions are actual appl...

Страница 31: ...em Components Description HHT Component LINK DV4 30B Includes one piece 3 in x 30 ft Flex one piece 3 in x 4 ft Flex Cap Adapter Linear to Coaxial with Flashing Dura Vent GS Catalog 923GK Colineal Fle...

Страница 32: ...v H 10 08 32 R 2 13 14 15 6 7 8 10 12 11 9 1 3 4 5 Service Parts Diagram Columbia Bay Insert COLBAY INS Beginning Manufacturing Date April 2003 Ending Manufacturing Date ______ Service Parts Part numb...

Страница 33: ...bly with Glass DOOR COLBAY INS 12 Door Crown 462 0150 13 Door Face Access 7008 117 14 Burner with Neck Assembly 7002 005 Y 15 Refractory Support Right 7002 129 Anti Bang Kit 842 5040 Baffle Seal 7002...

Страница 34: ...ay be ordered from an authorized dealer Stocked at Depot ITEM DESCRIPTION SERIAL PART NUMBER 1 Pilot Assembly NG for LP use LP Pilot Orifice 230 1781 Y Pilot Assembly NG with Injector 842 4280 Y 2 Spe...

Страница 35: ...rable under this warranty is limited to the purchase price of the product In no event shall HHT be liable for any incidental or consequential damages caused by defects in the product Adjustments regul...

Страница 36: ...ized and approved by HHT in writing This warranty does not apply to non HHT venting components hearth components or other accessories used in conjunction with the installation of this product This war...

Страница 37: ..._____________________________________________________________ ________________________________________________________________________________ Printed in U S A Copyright 2008 This product may be cover...

Отзывы: