10

Troubleshooting

With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do 
experience a problem, this troubleshooting guide will assist a qualified service person in the diagnosis of a problem and the 
corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician.

Symptom

Possible Cause

Corrective Action

1.  After repeated trig-
gering of the piezo 
button, the spark ignitor 
will not light the pilot.

a.  Defective ignitor.

Check the spark at the electrode and pilot. If no spark and electrode 
wire is properly connected, replace the ignitor.

b.  Defective pilot or 
misaligned electrode 
(spark at electrode).

Using a match, light the pilot. If the pilot lights, turn off the pilot and 
trigger the piezo button again. If the pilot lights, an improper gas/air 
mixture caused the bad lighting and a longer purge period is recom-
mended. If the pilot will not light, ensure the gap at the electrode and 
pilot is one-eighth (1/8) inch to have a strong spark. If the gas is OK, 
replace the pilot.

c.  No gas or low gas 
pressure.

Check the remote shut-off valve from the appliance. Usually, there is 
a valve near the gas main. There can be more that one (1) valve from 
the appliance and the main.

d.  No LP in tank.

Check the LP (propane) tank. You may be out of fuel.

2.  The pilot will not stay 
lit after carefully follow-
ing the lighting instruc-
tions.

a.  Defective thermo-
couple.

Check that the pilot flame impinges on the thermocouple. Clean and /or 
adjust the pilot for maximum flame impingement.

Ensure that the thermocouple connection at the gas valve is fully 
inserted and tight (hand tighten plus 1/4 turn).

Disconnect the thermocouple from the valve, place one millivolt lead 
wire on the tip of the thermocouple and the other meter wire on the 
thermocouple copper lead. Start the pilot and hold the valve knob in. If 
the millivolt reading is less than 15mV, replace the thermocouple.

b.  Defective valve.

If the thermocouple is producing more than 15 millivolts, replace faulty 
valve.

3.  The pilot is burning, 
there is no gas to the 
burner, the valve knob is 
in the ON position, and 
the ON/OFF switch is in 
the ON position.

a.  ON/OFF switch or 
wires defective.

Check the ON/OFF switch and wires for proper connections. Place the 
jumper wires across the terminals at the switch. If the burner comes on, 
replace the defective switch. If the switch is OK, place the jumper wires 
across the switch wires at the gas valve. IF the burner comes on, the 
wires are faulty or connections are bad.

b.  Thermopile may 
not be generating 
sufficient millivoltage.

If the pilot flame is not close enough physically to the thermopile, adjust 
the pilot flame.

Be sure the wire connections from the thermopile at the gas valve ter-
minals are tight and that the thermopile is fully inserted into the pilot 
bracket. 

Check the thermopile with a millivolt meter. Take the reading at TH-
TP&TP terminals of the gas valve. The meter should read 325 millivolts 
minimum, while holding the valve knob depressed in the pilot position, 
with the pilot lit, and the ON/OFF switch in the OFF position. Replace 
the faulty thermopile if the reading is below the specified minimum.

With the pilot in the ON position, disconnect the thermopile leads from 
the valve. Take a reading at the thermopile leads. The reading should 
be 325 millivolts minimum. Replace the thermopile if the reading is 
below the minimum.

Содержание TOPAZ Direct Vent Room Heater 839-1290

Страница 1: ...n may result causing property damage personal injury or death This appliance may be installed as an OEM installation in manufactured home USAonly or mobile home and must be installed in accordance wit...

Страница 2: ...par un technicien qualife et ou muni d une licence de mani re respecter les r glements municipaux Dans la R publique de Massachusetts l installation doit tre effectu e par un plombier ou un installat...

Страница 3: ...as Information A Fuel Conversions 23 B Gas Pressures 25 C Gas Connection 26 Section 7 Electrical Information A Recommendation for Wire 27 B Connecting to the Appliance 27 C Standing Pilot Ignition Sys...

Страница 4: ...ING Do NOT use this appliance if any part has been under water Immediately call a quali ed service technician to inspect the unit and to replace any part of the control system and any gas control whic...

Страница 5: ...ent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB...

Страница 6: ...ive surface See page 34 Remove log set and component pack from rebox Report to your dealer any parts damaged in shipment particularly the condition of the glass Read all of the instructions before sta...

Страница 7: ...ll appliance to all clearance speci cations in manual WARNING B Clearances Figure 3 1 Model A B C D E F G Topaz Inches 6 1 2 6 1 54 36 40 23 Millimeters 165 152 25 1372 914 1016 584 NOTE Flooring bene...

Страница 8: ...aintain vent clearance to combustibles as speci ed WARNING Do not pack air space with insulation or other materials Failure to keep insulation or other materials away from vent pipe may cause re HORIZ...

Страница 9: ...MIN RMAX 1 cap 3 feet 2 x Q ACTUAL 2 caps 6 feet 1 x Q ACTUAL 3 caps 9 feet 2 3 x Q ACTUAL 4 caps 12 feet 1 2 x Q ACTUAL QMIN termination caps x 3 RMA X 2 termination caps xQACTUAL N 6 inches non viny...

Страница 10: ...NING Diagonal runs have both vertical and horizontal vent aspects when calculating the effects Use the rise for the vertical aspect and the run for the horizontal aspect See Figure 5 1 Two 45 elbows m...

Страница 11: ...is 20 ft 6m when the vertical vent rise is 10 ft 3m The minimum horizontal vent run is 6 in 152mm Horizontal sections require a 1 4 in 6mm rise for every 12 in 305mm of horizontal travel Exterior Vent...

Страница 12: ...et a twist lock adapter is built into the appliance at the factory Wall thickness may vary Remember to include wall thickness in minimum clearances when figuring venting lengths for your installation...

Страница 13: ...If the snorkel termination must be installed below grade i e basement application proper drainage must be provided to prevent water from entering the snorkel termination Do not backfill around snorke...

Страница 14: ...tal top to vinyl standoff SCREWS Apply sealant to all four sides VINYL SIDING Figure 5 8 8 in 203mm 7 in 178mm 7 in 178mm 6 in 152mm Figure 5 7 NOTE Some termination caps may cause the vent pipe to be...

Страница 15: ...bows Step 2 Set the gas appliance in its desired location Drop a plumb bob down from the ceiling to the position of the appliance flue exit and mark the location where the vent will penetrate the ceil...

Страница 16: ...code requirements as outlined in the current CAN CGA B149 Installation Codes in Canada the National Fuel Gas Code NFPA 54 ANSI Z223 1 in USA or local codes Note that for steep roof pitches the vent he...

Страница 17: ...be framed and sheetrocked with standard construction materials however refer to these installation instructions for the minimum allowable clearance between the outside of the vent pipe and the combus...

Страница 18: ...f sheathing Step 5 Using tin snips cut the support box from the top corners down to the roofline and fold the resulting flaps over the roof sheathing Figure 5 18 Before nailing it to the roof run a be...

Страница 19: ...n 76mm Connect the flex pipe to the retro connector and attach with sheet metal screws Step 6 Push the flex pipe back up into the ceiling support box center the retro connector and attach it to the su...

Страница 20: ...mm Flex Liner Pipe Length Optional Chimney Liner Termination Cap Co Axial to Co Linear Connector 30 ft 9m of 3 in 76mm Flex Liner Exhaust Section Pipe Length Optional 4 ft 1m of 3 in 76mm Flex Liner A...

Страница 21: ...this length extended to its nominal length Be sure to leave 2 3 in 51 76mm of flex above the existing chimney to allow for connection to the termination kit Step 3 Secure the flashing to the top of t...

Страница 22: ...Secure the top adapter to the flashing Use three sheet metal screws through the side of the top adapter into the flange on the flashing Figure 5 28 Twist lock the high wind termination cap on to the t...

Страница 23: ...urner by rst remov ing the two screws indicated and lifting the burner out Figure 6 3 Remove the three screws on the front of the burner support Set screws aside Figure 6 5 Remove the main burner ori...

Страница 24: ...and adapter cap Fire Risk Explosion Risk Disconnect any electrical cords and turn off gas supply to unit before proceeding if converting fuel on an appliance already fully installed WARNING Replace pi...

Страница 25: ...below Proper input pressures required for optimum appliance per formance gas line sizing requirements need to be followed from NFPA51 WARNING Fire Risk Explosion Hazard High pressure will damage valv...

Страница 26: ...th local building codes if any If not follow ANSI Z223 1 Instal lation should be done by a quali ed installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts...

Страница 27: ...ermostat see individ ual thermostat instructions to ensure proper operation of appliance 4 Use low resistance thermostat wire for wiring from igni tion system to the wall switch and thermostat 5 Use t...

Страница 28: ...ng controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Shock hazard Replace damaged wire with type 105O C rated wire Wire must have high temperatu...

Страница 29: ...adapter before installing as indicated in Figure 8 6 Figure 8 2 Remove inner collar adapter KIT CONTENTS Rear vent grille TOOLS REQUIRED Power drill 2 Phillips bit high temp silicone sealant optional...

Страница 30: ...Home Technologies approved accessories may be used safely WARNING C Leg Leveling System Figure 8 8 Thread Allen bolts through nuts until ush The Allen bolts and nuts are included in the component pac...

Страница 31: ...TRUCTIONS FOR QUARTET AND SOLITAIRE FACE OPTIONS Figure 8 11 Solitaire Front Quartet Front Spacer NOTE The brick supplied with the Topaz is not an optional accessory The brick must be installed for sa...

Страница 32: ...talled side panel and support the other end with one hand Install the remaining side panel and bend over the tabs to hold it in place Rest top panel baf e on sides and slide top panel baf e left or ri...

Страница 33: ...omplete your log set applica tion reinstall the glass and the front of the unit H Mineral Wool Follow ember placement instructions in manual Do NOT place embers directly over burner ports Replace embe...

Страница 34: ...ckaging Place blower under appliance Attach blower from front with 4 screws to blower bracket Figure 8 27 Install snap disc in bracket Attach bracket to re box with 5 16 in wrench Figure 8 28 Connect...

Страница 35: ...08 Page 35 Quadra Fire Topaz 7009 113G Figure 8 31 Blower Wiring Diagram Fan Speed Control Thermal Disc 110 VAC Power Cord BLAC K Bushing Strain Relief GREEN BLACK Ground Fan Assembly BLACK BLACK WHIT...

Страница 36: ...wingnut to lock in place K Damper Adjustment Make adjustment Let appliance warm up before adjusting Loosen screw using a Phillips head screwdriver Pivot the vertical damper adjustor in 1 4 in 6mm incr...

Страница 37: ...the baf e adjustment Ensure that there are no gas leaks Ensure that the glass is sealed and in the proper posi tion Ensure that the ow of combustion and ventilation air is not obstructed front grille...

Страница 38: ...r of the appliance May need to remove face front first 5 Push in gas control knob slightly and turn clockwise to the OFF position Do not force 6 Wait five 5 minutes to clear out any gas Smell for gas...

Страница 39: ...detectors Smoke and odors may be irritating to sensitive individuals CAUTION Prevent accidental appliance operation when not attended Unplug or remove batteries from remote control if absent or if ap...

Страница 40: ...e thermocouple connection at the gas valve is fully inserted and tight hand tighten plus 1 4 turn Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocoupl...

Страница 41: ...g exhaust gases back into the system Check for proper vent connection at ue collar and all vent joints c Horizontal vent improperly pitched The horizontal vent cap should slope down only enough to pre...

Страница 42: ...ratching or slamming glass Do NOT use abrasive cleaners Use a hard water deposit glass cleaner on white lm Do NOT clean glass when hot Turn off appliance after 3 4 hours of operation and ALLOW TO COOL...

Страница 43: ...aint as neces sary 2 Replace appliance if rebox has been perforated Burner Ignition and Operation 1 Verify burner is properly secured and aligned with pilot or igniter 2 Clean off burner top inspect f...

Страница 44: ...for reference only For clearances refer to Section 3 Figure 12 1 Appliance Dimensions B C A K L M N O D E F G H I J Location Inches Millimeter Location Inches Millimeter A 27 3 8 695 I 19 3 8 492 B 7...

Страница 45: ...9 1 4 in 235mm 6 1 2 in 165mm 6 5 8 in 168mm 17 24 in 432 610mm 11 3 4 in 298mm 5 3 4 in 146mm 6 5 8 in 168mm 6 3 8 in 162mm 6 1 2 in 165mm 9 5 8 in 244mm 6 5 8 in 168mm 6 1 2 in 165mm 6 3 8 in 162mm...

Страница 46: ...vanized SLP48M 46 DVA 48 4DT 48 4D4 SV4L48 48 Pipe Length Black SLP48 BK 46 DVA 48B 4DT 48B 4D4B SV4LB48 Adjustable Length 3 6 Black SLP6A BK Adjustable Length 3 6 Galvanized SLP6AM Adjustable Length...

Страница 47: ...e Roof Flashing 4 to 8 pipes 6 RF4 8M Storm Collar SLP SCM 46DVA SC 4DT SC 4DSC SV4FC Trim Plate Black 4DT TP 4DFPB SV4LA Wall Support Band SLP HVSM 46 DVA WS 4DT WS B 4DWS SV4BM Wall Thimble Support...

Страница 48: ...r Retainer Assembly 20 Igniter Piezo 3 Door Assembly 12 Side Kit 21 Switch Bracket 4 Burner Assembly 13 Valve Bracket 22 Grille Rear Vent 5 Pilot Assembly 14 Back Shield Lower 23 Grille Top Vent 6 Ref...

Страница 49: ...ting Bracket Bottom 7009 102 25 Cast Mounting Bracket Top 7009 101 Component Pack Includes ON OFF Valve Mineral Wool Pilot Injector EZ LP 35 Conversion Regulator S I T LP LP Ori ce 073 Conversion Labe...

Страница 50: ...in 200 2940 Flex Line 3 8 Flare x 22L 7000 197 Gasket Cover Plate 7010 160 Gasket Elbow 460 0610 Glass Assembly 7011 015 22 Grille Rear Vent Matte Black 844 9830 22 Grille Rear Vent Porcelain Cr me 8...

Страница 51: ...art below Topaz Shipping Kit 842 5140 13 Valve Bracket 7009 104 15 Valve S I T LP 842 0230 15 Valve S I T NG 842 0240 Wire Harness 7009 114 IMPORTANT THIS IS DATED INFORMATION The most current informa...

Страница 52: ...celain Mahogany 844 9810 Warming Shelves Porcelain Midnite Blue 844 9821 Warming Shelves Powder Coat Creme WSLG CCR Warming Shelves Powder Coat Linden Green WSLG CLG IMPORTANT THIS IS DATED INFORMATIO...

Страница 53: ...September 1 2008 Page 53 Quadra Fire Topaz 7009 113G F Service and Maintenance Log Date of Service Performed By Description of Service...

Страница 54: ...onditions Exclusions and limitations 9 01 08 CONDITIONS EXCLUSIONS LIMITATION OF LIABILITY This warranty applies to the original owner and is transferable up to two years from date of purchase to the...

Страница 55: ...ine uorine or other damaging chemicals the appliance is subject to prolonged periods of dampness or condensation or there is any damage to the appliance or other components due to water or weather dam...

Страница 56: ...This product may be covered by one or more of the following patents United States 4593510 4686807 4766876 4793322 4811534 5000162 5016609 5076254 5113843 5191877 5218953 5263471 5328356 5341794 534798...

Отзывы: