SANTA FE FREESTANDING

N. Thermostat Controls

TEMPERATURE (HEAT / OFF) SWITCH:

Set this switch to HEAT to control your appliance. The off 

position will disable the appliance.

SET (MULTI- FUNCTION) SLIDE SWITCH:

This provides easy access to common settings, and should 

always remain in RUN unless items are being adjusted.

Figure 14.1

O. Thermostat Setup Options

Setup options for how the thermostat will function are 

performed using a menu on the display screen.

TO ACCESS THE SETUP MENU:

Move the TEMPERATURE switch into the OFF position, 

and then hold down the COPY button for approximately 5 

seconds until the screen changes. The menu will always 

start with item #01, and is advanced to each following item 

by a single press of the NEXT button. The options for each 

item are changed using the UP or DOWN buttons.

ITEM #01 (CLK = CLOCK FORMAT):

• 

12Hr, default:

 This displays the clock times using 

standard AM and PM values. 

• 

24Hr: This displays the clock times using the military-

time format (example 22:00 hours, without using AM 

or PM).

ITEM #02 (TMP = TEMPERATURE SCALE):

• 

F, default: Shows all temperature values in Fahrenheit.

• 

C: Shows all temperature values Celsius.

ITEM #03 (PROGRAMMING STYLE):

• 

7 Day, default:

 This style uses a separate program 

routine for each of the 7 days in the week.

• 

5/2 Day:

 This style uses a weekday program routine 

for Monday, Tuesday, Wednesday, Thursday, Friday, 

and a separate weekend program routine for Saturday 

and Sunday.

• 

Manual Non-Programmable:

 In this setting, there are 

no program routines for the thermostat to follow and 

the temperature control will be set only by the UP and 

DOWN buttons on the front panel.

ITEM #04 (PERD = EVENT OR PERIOD QUANTITY):

• 

4P, default:

 Thermostat uses four Events per day 

(called MORN, DAY, EVE

, and NITE

).

• 

2P: The thermostat uses two Events per day (called 

DAY 

and NITE

).

NOTE:

 

When thermostat is set to “Manual” non-

programmable mode, all positions of the SET 

slide switch will act like RUN.

UP / DOWN BUTTONS:

The UP and DOWN buttons are used to control the set 

temperature, or adjust any other on-screen items. An 

items flashing, is the item currently being adjusted.

HOLD BUTTON:

This button activates and deactivates the manual 

Temperature HOLD feature, which maintains a 

fixed set temperature indefinitely without following a 

program routine.

COPY BUTTON:

This is used to copy temperature program items from one 

day to the next. Also used to to access the menu setup.

NEXT BUTTON:

This is used when setting items such as software options, 

and temperature programs when they are flashing on the 

screen. Pressing the NEXT button will cycle through which 

item is flashing.

NOTE: 

Event or Period Quantity feature is not accessible 

during Manual Non-Programmable mode.

ITEM #07 (DLAY = DELAY TIME): 

• 

5, default: Thermostat waits 5 minutes before turning 

the system back on after it was last run. This internal 

delay prevents the appliance from turning on too 

quickly after shutting down. The 5 minute setting is fine 

for most applications.

• 

2:

 Same operation as above but reduced to 2 minutes 

between state changes.

NOTE: 

There is no delay available when the thermostat 

is manually turned up and down.

Содержание SANTAFE-C

Страница 1: ...tions is not followed exactly a fire could result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any oth...

Страница 2: ...charge lectrique D connectez le fil lectrique de la prise de contact avant le service Remplacez la vitre seulement avec une vitre c ramique de 5 mm disponible chez votre fournisseur Pour allumer mont...

Страница 3: ...hermostat Other Features 16 S Thermostat Battery Replacement 17 T Frequently Asked Questions 18 3 Maintenance and Service 19 A Proper Shutdown Procedure 19 B Quick Reference Maintenance Chart 19 C Gen...

Страница 4: ...ectronic components and glass X X X Factory installed blowers X Molded refractory panels X Ignition Modules X Firepots burnpots mechanical feeders auger assemblies X Vent Free burners Vent Free cerami...

Страница 5: ...ranging a warranty call Travel and shipping charges for parts are not covered by this warranty Limited Catalyst Warranty o For wood burning products containing a catalyst the catalyst will be warrante...

Страница 6: ...to water or weather damage which is the result of but not limited LIMITATIONS OF LIABILITY have other rights which vary from state to state EXCEPT TO THE EXTENT PROVIDED BY LAW HHT MAKES NO EXPRESS W...

Страница 7: ...local codes In the absence of local codes you must comply with the ASTM E1509 04 ULC S627 00 UM 84 HUD and ULC ORD C 1482 B BTU Efficiency Specifications Emissions Report 0061PM077E EPA Certification...

Страница 8: ...d in the bedroom The size of the room must be at least 50ft per 1 000 Btu hr stove input if the stove exceeds the room size out air must be installed G California Prop65 WARNING This product and the f...

Страница 9: ...rk Standard grade pellets high ash pellets Lower Ash Content Material Softwoods Fuels with low mineral content Premium grade pellets Corn Moisture content must be 15 or less Corn must be free of debri...

Страница 10: ...er possible However we do recommend trying various brands before purchasing multi ton lots to ensure your satisfaction Changing to Different Fuel Type Empty the hopper of the previous fuel Thoroughly...

Страница 11: ...orner Figure 11 1 Turn it to the high setting by pushing the top of the control switch in and then adjust the thermostat to its highest setting Remove the right side panel and the red call light locat...

Страница 12: ...mm If the fire has tall flames with black tails and seems somewhat lazy the feed rate will need to be reduced This is done by sliding the fuel adjustment control rod down which will reduce the feed If...

Страница 13: ...have dropped into the ash pan then return the handle to fully closed position 3 Press the reset button 4 The appliance will then being its startup sequence Restarting After a Power Failure 1 For an el...

Страница 14: ...rammable In this setting there are no program routines for the thermostat to follow and the temperature control will be set only by the UP and DOWN buttons on the front panel ITEM 04 PERD EVENT OR PER...

Страница 15: ...ime of the next upcoming scheduled event is reached MORN DAY EVE OR NITE While the temporary changed set temperature is in effect the word OVERRIDE will be shown on the display screen To cancel move T...

Страница 16: ...is pressing COPY button to set desired days with original setting NOTE The word COPY will not appear on the display for Monday but will display each day afterwards for approximately one second and the...

Страница 17: ...4 Figure 17 2 Full battery icon Figure 17 3 Low battery icon CONNECT THERMOSTAT WIRES TO APPLIANCE There is a 4 screw terminal block located on the back lower left corner of the stove directly above t...

Страница 18: ...noisy blowers is from the impellers becoming dirty over time See maintenance and service section for maintaining and servicing What is the metal object with the bend in it that came inside the plasti...

Страница 19: ...fire pot becomes obscured OR X Heat Exchanger Drop Tube Every 1 ton of fuel OR X Hopper Every 1 ton of fuel or when changing fuel types OR X Venting System More frequently depending on the fuel type...

Страница 20: ...h out the exhaust instead of into the room c Open door There are 2 cleaning slide plates to the left and right of the fire pot with finger holes Pull both slide plates out and sweep the remaining ash...

Страница 21: ...er Frequency Monthly or after burning 50 bags of fuel or when changing fuel type By Homeowner After burning approximately 1 ton of fuel you will need to clean the hopper to prevent sawdust build up A...

Страница 22: ...ld be inspected periodically to make sure there is a good seal 13 Cleaning Exhaust Blower Requires No Lubrication Frequency Yearly or as needed By Qualified Service Technician Task Contact your local...

Страница 23: ...rrect Flame Size Yellow White in Color Correct Figure 23 3 Ash Build Up in Firebox Pellets Back Up In Feed Tube Firepot Overfills Tall Lazy Flame Orange in Color Incorrect Figure 23 1 Figure 23 2 D So...

Страница 24: ...ed pellets in fire pot Fire pot clean out plate not closed Fire pot is dirty The ignition hole between the igniter bracket and fire pot is blocked Igniter not working Control box defective Check that...

Страница 25: ...fails to start or does not shut off Blower not plugged in Blower is clogged with ash Blower is defective Control box is defective Check that blower is plugged into wire harness Clean exhaust system Re...

Страница 26: ...en disconnect the white and purple wires e Remove wing nut and hold down bracket and then remove blower f Re install in reverse order g Attach new tie wire to hold wires together Figure 26 2 Figure 26...

Страница 27: ...top from appliance Two fasteners are located outside the hopper on each side The other two are located in the hopper along the back Figure 26 1 Remove the rear screen of the appliance be sure the vent...

Страница 28: ...ting up 2 Repeat for left brick 3 Reinstall bricks in reverse order ensuring that the bricks are flush against the back wall of the firebox Figure 28 4 28 5 Figure 28 1 Brick is flush against back wal...

Страница 29: ...thermostat and let the appliance completely cool down After the appliance has cooled down unplug it and remove the ash drawer 2 Remove side panel 3 The wire leads to the igniter are connected to the w...

Страница 30: ...so an internal blue light located in the upper left corner of the control box When you plug in the appliance the blue light will automatically start blinking 6 times in a row for 60 seconds and then w...

Страница 31: ...on the back of the auger tube in the center of the appliance and has a reset button To access it remove the right side panel If the fire tries to burn back into the feed system or push exhaust up the...

Страница 32: ...itch Junction Box High Med Low Heat Output Switch Reset Button Reset Button Combustion Blower Convection Blower TERMINAL BLOCK CENTER 2 SCREWS FOR THERMOSTAT WIRES POWER OUTLET Figure 32 1 Figure 32 2...

Страница 33: ...33 April 2 2019 7050 802B SANTA FE FREESTANDING Date of Service Performed By Description of Service C Service Maintenance Log...

Страница 34: ...Parts SANTAFE C Beginning Manufacturing Date April 2019 Ending Manufacturing Date Active Pellet Stove Part number list on following page 12 18 1 3 19 22 20 21 23 25 26 27 31 28 29 30 24 33 32 18 2 4 5...

Страница 35: ...3 Pc 7019 007 Grill Bracket Cover 7019 199 7 Pull Rod Assembly 7019 009 7 1 Pull Rod Black Nickel SRV7019 172 Y 7 2 Spring Firepot 200 2050 Y 7 3 Washer 5 16 Pkg of 10 7000 579 10 Y Pkg of 50 3 30 020...

Страница 36: ...1 4 Pkg of 24 229 1230 24 Y 17 2 Hinge Female SRV450 2910 Y 17 3 Glass Assembly SRV7021 032 Y Glass Tape 1 2 X 1 16 10 Ft 240 0290 10 Y 35 Ft SRV240 0290M 17 4 3 4 Inch Rope Gasket 50 Ft SRV240 0051M...

Страница 37: ...Pkg of 10 812 3780 10 Y 28 Wire Harness Junction Box SRV7001 194 Y Switch 3 Position Heat Output Rocker Switch 812 3500 Y Reset Button Assembly SRV7000 040 Fuse 7 Amp Junction Box Pkg of 10 812 0380 1...

Страница 38: ...et LOGS 30 OE Y Log Left 7050 144 Log Right 7050 143 Louvre Grille Assembly Complete Set Black Nickel GRL SFI NB Nickel GRL SFI NL Grill Bar Scraper Black Nickel 7019 191 Nickel SRV7019 164 Upper Gril...

Страница 39: ...kg of 24 226 0130 24 Y Pin 3 16 x 1 2 7000 229 Rivet Iron 1 4 X 1 1 4 Pkg of 25 229 0090 25 Screw 8 32 X 1 4 Qty 40 225 0240 40 Screw Hwh 1 4 20 X 3 4 Ns Pkg of 25 220 0080 25 Y Screw Flat Head Screw...

Страница 40: ...purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Deale...

Отзывы: