A.  Recommendation for Wire

This appliance requires 110-120 VAC be wired to the 
junction box either for use of optional accessories or for 
proper operation of the appliance.

10 

10 

Electrical Information 

 

Note:

 This appliance must be electrically wired and grounded 

in accordance with local codes or, in the absence of local 
codes, with 

National Electric Code ANSI/NFPA 70-latest 

edition 

or the 

Canadian Electric Code, CSA C221.1

.

B.  Connecting to the Appliance

Wire 110V to electrical junction box.

Do NOT wire 110V to valve.

Do NOT wire 110V to wall switch.

•  Incorrect wiring will damage millivolt valves.

•  Uninterrupted or continuous power is required 

at all times in IPI system 

EXCEPT

 when using 

battery back-up.

C.  IntelliFire Ignition System Wiring

This appliance requires a 110 VAC supply to the appli-
ance junction box for operation. A wiring diagram is shown 
in Figure 10.1.

This appliance is equipped with an IntelliFire control valve 
which operates on a 3 volt system. 

This appliance is supplied with a battery pack and a 3 volt 
AC transformer, which requires the installation of the sup-
plied junction box. It is highly recommended that the junc-
tion box be installed at this time to avoid reconstruction.

The battery pack requires two D cell batteries (not includ-
ed). Batteries cannot be placed in the battery pack while 
using the 3 volt AC transformer. Conversely, the trans-
former must be unplugged if the battery pack is used.

 CAUTION

Battery polarity must be correct or module damage will 
occur.

WARNING

Figure 10.1  IntelliFire Pilot Ignition (IPI) Wiring Diagram

Note 

1:  Ignition module, valve, pilot 

and wall switch operate on 3 volts. 

Note 

2:  Plug QWSK-MLT wall switch 

kit into the REM/AUX outlet on the 
junction box.

IPI

VALVE

ORANGE

WIRES WITH LABEL “FOR USE WITH REMOTE OR WALL SWITCH ONLY”

(LOCATED UNDER FIREPLACE)

GREEN

RED

RED

GROUND

PIGTAIL

GREEN

AUX

CONNECTION

FRONT VIEW

REAR VIEW

G      Y      R

BLACK

BLACK

AC

PLUG

FAN

CONNECTION

ORANGE

BATTERIES

1
2
3
4
5
6
7
8

R

Y

G

ORANGE

IPI

MODULE

FLAME

SOLENOID

FLAME HIGH/LOW

BLACK

RED

BLACK

RED

RED

BLACK

RED

(MALE/FEMALE)

RED

(FEMALE/MALE)

ADAPTER WIRES

BROWN

BROWN

GROUND

BLACK

BROWN

BROWN

RED

GREEN

YELLOW (HNG)

WHITE (HTL)

BATTERY

IPI PILOT

3V DC

FLAME ON

YELLOW

YELLOW

FAN THERMOSTAT

FACTORY

CONNECTED

TOGETHER

CONTINUOUS

110VAC

SUPPLY

BLACK

WHITE

GROUND

HOT

FA

N

TRANS

REM/AUX

NEUTRAL

FIREBOX LIGHTS

•  A 110-120 VAC circuit for this product must be protected 

with ground-fault circuit-interrupter protection, in 
compliance with the applicable electrical codes, when it is 
installed in locations such as in bathrooms or near sinks.

•  Incorrect wiring will override IPI safety lockout and may 

cause explosion.

Содержание QV36A-FB

Страница 1: ...OT DISCARD Important operating and maintenance instructions included Read understand and follow these instructions for safe installation and operation In the Commonwealth of Massachusetts installation...

Страница 2: ...Information Listing Label Information Location Gas and Electric Information Serial Number Type of Gas The model information regarding your specific appliance can be found on the rating plate usually...

Страница 3: ...nstalling Non combustible Facing Material 22 8 Installing Vent Pipe A Assembly of Vent Sections 23 B Disassembly of Vent Sections 25 C Installing Heat Shield and Horizontal Termination Cap 26 D Instal...

Страница 4: ...dered non combustible materials E Combustible Materials Specification Materials made of or surfaced with wood compressed paper plant fibers plastics or other material that can ig nite and burn whether...

Страница 5: ...ed heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB STRUCTIONS Inspection The state or local gas ins...

Страница 6: ...kaging The vent system components and trim doors are shipped in separate packages The gas logs may be packaged separately and must be field installed Report to your dealer any parts damaged in shipmen...

Страница 7: ...ght fracture lines or spider webbing on the surface of the material Cracks that are less than 1 32 in wide and less than 3 in long If cosmetically unacceptable such cracks may be repaired with the SRV...

Страница 8: ...access Locate appliance away from traffic areas A Selecting Appliance Location When selecting a location for your appliance it is important to consider the required clearances to walls see figure 3 1...

Страница 9: ...inside a chase Construction of the chase may vary with the type of build ing These instructions are not substitutes for the require ments of local building codes Local building codes MUST be checked C...

Страница 10: ...Ceiling Combustible Floor Combustible Flooring Behind Appliance Sides of Appliance Front of Appliance Inches 10 52 17 1 4 41 1 2 32 1 2 0 0 1 1 2 36 Millimeters 254 1321 438 1054 825 0 0 25 13 914 WAL...

Страница 11: ...ltiple Vertical Termination Figure 4 2 specifies minimum vent heights for various pitched roofs See Figure 4 4 for specific clearances 3 foot minimum in snow regions HORIZONTAL OVERHANG VERTICAL WALL...

Страница 12: ...ches non vinyl sidewalls 12 inches vinyl sidewalls O 18 inches non vinyl soffit and overhang 42 inches vinyl soffit and overhang P 8 ft QMIN RMAX 1 cap 3 feet 2 x Q ACTUAL 2 caps 6 feet 1 x Q ACTUAL 3...

Страница 13: ...re 5 1 Figure 5 1 5 5 Vent Information and Diagrams A Vent Table Key The abbreviations listed in this vent table key are used in the vent diagrams C Measuring Standards Vertical and horizontal measure...

Страница 14: ...Maximum V1 H1 30 ft 9 1 m Maximum Fire Risk Explosion Risk Do NOT pack insulation or other combustibles between ceiling firestops ALWAYS maintain specified clearances around venting and firestop syste...

Страница 15: ...1 ft 6 in 3 ft 2 ft 6 in 6 ft 3 ft 6 in 9 ft 4 ft 10 ft 4 ft 6 in 12 ft 5 ft 6 in 15 ft 6 ft 6 in 18 ft 7 ft 6 in 21 ft HT 21 ft Max VT 40 ft Max VT HT 30 ft Max Note A section of vertical pipe 12 inc...

Страница 16: ...e horizontal component is less than 5 feet then the total vent run can be extended to 40 feet VT Min HT Max 1 ft 6 in 3 ft 2 ft 6 in 6 ft 3 ft 6 in 9 ft 4 ft 10 ft 4 ft 6 in 12 ft 5 ft 6 in 15 ft 6 ft...

Страница 17: ...Min HT Max 1 ft 6 in 3 ft 2 ft 6 in 6 ft 3 ft 6 in 9 ft 4 ft 10 ft 4 ft 6 in 12 ft 5 ft 6 in 15 ft 6 ft 6 in 18 ft 7 ft 6 in 21 ft HT 21 ft Max VT 40 ft Max VT HT 30 ft Max Note A section of vertical...

Страница 18: ...o heat shield is necessary If your local inspector requires the wall shield firestop on both sides then both wall shield firestops must have a heat shield attached to them Fire Risk Explosion Risk Mai...

Страница 19: ...tic Shield Note An additional ceiling firestop is not required if attic shield is used Frame opening for attic shield Attic shield may be installed above or below ceiling see Figure 6 4 Secure with th...

Страница 20: ...one Cover Plate to the top of the appliance Figure 7 1 Remove Screws 2 Bend the four pre cut tabs up to expose the top of the appliance Place the Heat Zone cover plate on the insulation inside the uni...

Страница 21: ...intain specified clearances around the appliance Do NOT notch into the framing around the appliance spacers Failure to keep insulation framing or other material away from the appliance may cause fire...

Страница 22: ...Figure 7 9 Attaching Non combustible Facing Material D Installing Non combustible Facing Material Center and attach two top boards to the framing members See Figure 7 10 Use fasteners from fastener pa...

Страница 23: ...nd the seams are not aligned see Figure 8 5 Tug slightly on sectionAto confirm it has completely locked into place It is acceptable to use screws no longer than 1 inch to hold outer pipe sections toge...

Страница 24: ...slip section is too long the inner and outer flues of the slip section can be cut to the desired length Assembling Minimum Installations MI Sections MI sections are non unitized so that they can be c...

Страница 25: ...aced 120 apart may be used to do this see Figure 8 9 Horizontal Sections Horizontal sections of vent must be supported every 5 feet with a vent support or plumber s strap Figure 8 9 Securing Vertical...

Страница 26: ...ion codes Figure 8 13 Venting through the Wall Burn Risk Local codes may require installation of a cap shield to prevent anything or anyone from touching the hot cap Fire Hazard Impaired performance o...

Страница 27: ...burner operation HORIZONTAL OVERHANG VERTICAL WALL GAS DIRECT VENT TERMINATION CAP 12 X ROOF PITCH IS X 12 LOWEST DISCHARGE OPENING 2 FT MIN 20 INCHES MIN H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISC...

Страница 28: ...m collar around the exposed pipe section and align brackets Insert a bolt provided through the brackets and tighten nut to complete storm collar assem bly see Figure 8 18 Slide the assembled storm col...

Страница 29: ...fire condition Low pressure may cause explosion Verify minimum pressures when other household gas appliances are operating Install regulator upstream of valve if line pressure is greater than 1 2 psig...

Страница 30: ...eck with local authorities Ensure that gas line does not come in contact with outer wrap of appliance Follow local codes Incoming gas line should be piped into the valve compartment and connected to t...

Страница 31: ...econstruction The battery pack requires two D cell batteries not includ ed Batteries cannot be placed in the battery pack while using the 3 volt AC transformer Conversely the trans former must be unpl...

Страница 32: ...10 120 VAC source for added features the fireplace may have installed Electrical ratings for the control box are 110 VAC 60 Hz and is required for operation of this device Installation precautions Thi...

Страница 33: ...h Once a location is chosen and the electrical box is installed proceed as follows Install the provided control wire from the fireplace to the switch location Use caution not to stress the wire around...

Страница 34: ...lace at 20 F over set point and turn it back on at 20 F below set point Up and Down Arrows Push to adjust set point temperature under automatic control AUX Auxiliary Button Button Press Turns on auxil...

Страница 35: ...tions and reattach the cover plate to the outer shell If the box is being wired from the INSIDE of the appliance Remove the screw attaching the junction box receptacle to the outer shell rotate the ju...

Страница 36: ...must not interfere with Air flow through grilles or louvers Operation of louvers or doors Access for service 14 IN 23 IN 12 IN MIN 18 IN MIN 12 IN MAX 1 IN MAX 3 IN MIN Risk of Fire Non combustible c...

Страница 37: ...ement instructions in manual Do NOT place embers directly over burner ports Replace ember material annually Improperly placed embers interferes with proper burner operation Placing the Ember Material...

Страница 38: ...UTION Logs are fragile Figure 12 1 1 1 6 6 5 5 4 4 3 3 2 2 Carefully remove the grate from the foam sup ports and then remove the foam supports from around the burner Figure 12 2 Place grate on the ba...

Страница 39: ...hat the bottom of the log conforms with the contour of the burner The outside of the log should rest on the grate The front of the log will rest against the right andiron LOG 1 SRV2062 701 Place log 1...

Страница 40: ...the bottom of log 6 should rest on the wedge shape on the end of log 3 LOG 5 SRV330 704 Place the Y end of log 5 against the corre sponding bump on log 3 The other end of the log should rest in the s...

Страница 41: ...he bottom of the glass door toward the firebox with slight upward pressure Latch the bottom spring latches securely onto the bottom glass door tabs G Burner Removal Only for Servicing Loosen the shutt...

Страница 42: ...g the air shutter To adjust loosen the wing nut Care should be taken when adjusting the air shutter so as not to cause the appliance to soot If sooting occurs the air shutter will need to be opened by...

Страница 43: ...replacement should be done by qualified technician Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provid...

Страница 44: ...TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electric switch do not use any phone in your building DO NOT CONNECT LINE VOLT AGE 110 120 VAC OR 220 240 VAC TO THE CONTROL...

Страница 45: ...nce will not be used for an extended period of time Property damage possible from elevated temperatures CAUTION Fire Hazard Keep combustible materials gasoline and other flammable vapors and liquids c...

Страница 46: ...ged into module Check voltage of transformer under load at spade connection on module with ON OFF switch in ON position Acceptable readings of a good transformer are between 3 2 and 2 8 volts AC b A s...

Страница 47: ...uity with a multimeter with ohms set at lowest range e Faulty module Turn ON OFF rocker switch or wall switch to OFF posi tion Remove ignitor wire I from module Place ON OFF Rocker switch or wall swit...

Страница 48: ...Handle glass assembly with care Note Clean glass after initial 3 4 hours operation Longer operation without cleaning glass may cause a permanent white film on glass CAUTION When cleaning glass door A...

Страница 49: ...f firebox has been perforated Burner Ignition and Operation 1 Verify burner is properly secured and aligned with pilot or igniter 2 Clean off burner top inspect for plugged ports corrosion or deterior...

Страница 50: ...nsions Use for reference only For framing dimensions and clearances refer to Section 3 Figure 16 1 Appliance Dimensions Location Inches Millimeters L 37 1 4 945 M 8 3 8 212 N 30 1 2 776 O 36 1 8 916 P...

Страница 51: ...76 to 610 10 1 2 in 267 mm 10 7 8 in 276 mm 45 7 3 8 in 187 mm 11 3 8 in 289 mm 1 1 4 in 32 mm 9 1 4 in 235 mm 13 1 4 in 337 mm 1 2 in TYP DVP90ST 90 Elbow 10 in 254 mm 10 in 254 mm 1 in 25 mm 12 in...

Страница 52: ...at shield is designed to be used on a wall 4 in to 7 1 4 in 102 mm to 184 mm thick If wall thickness is less than 4 in 102 mm the existing heat shields must be field trimmed If wall thickness is great...

Страница 53: ...5 8 in 625 mm 13 1 4 in 367 mm RF12M Roof Flashing Multi pak BEK Trap Cap Brick Extension 13 3 4 in 349 mm 5 in 127 mm 13 3 4 in 349 mm Cap Shield DRC RADIUS 13 7 8 in 352 mm 9 1 2 in 241 mm 14 in 35...

Страница 54: ...iginal purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HH...

Страница 55: ...OW RI QRUPDO XVH V D KHDWLQJ DSSOLDQFH VRPH FKDQJHV LQ FRORU RI LQWHULRU DQG H WHULRU VXUIDFH ILQLVKHV PD RFFXU 7KLV LV QRW D IODZ DQG LV QRW FRYHUHG XQGHU ZDUUDQW DPDJH WR SULQWHG SODWHG RU HQDPHOHG...

Страница 56: ...___________________________ ________________________________________________________________________________ ________________________________________________________________________________ __________...

Отзывы: