33
Quadra-Fire • Sapphire • 7055-116 Rev. G • 10/12
Figure 8.20
Install speed control to switch panel. Attach
knob to speed control.
Figure 8.21
Cut out the rheostat/speed control cover on rear
shield. Re-install rear shield.
Connect the blower to the power supply and turn on the
gas supply.
NOTE:
This blower utilizes a snap disc to control ON and
OFF operation. When the correct temperature is reached,
the blower will automatically turn ON. Use the rheostat/
speed control knob to adjust the fan speed to suit your
preferences.
SNAP
DISC
6 in. (152mm) BLACK
BLOWER
4 in. (102mm) WHITE
CORD
M
F
M
F
34 in. (864mm)
BLACK
34 in. (864mm)
WHITE
F
M
M
F
RHEOSTAT
F
F
M
F
Figure 8.22 Blower Wiring Diagram